RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

        Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

        Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

      • IGCC용 고온건식 탈화제의 반응속도 모사에 관한 연구

        박소진,이영우,민세홍,나재익,위영호 忠南大學校 産業技術硏究所 1999 산업기술연구논문집 Vol.14 No.1

        고온건식 탈황공정에서 탈황제의 황화, 재생 반응은 비촉매 기고 반응이다. 이러한 비촉매 기고 반응의 수학적 모사는 실험데이터의 설명, 공정의 설계 그리고 scale-up에 있어서 매우 중요한 정보가 된다. 탈황제의 황화, 재생 반응에는 spray dryer로 제조된 zinc titanate 탈황제를 사용하였고, 변형된 미반응핵 모델식에 적용하여 각 반응의 반응속도를 해석한 결과 탈황제의 황화반응에는 화학반응 저항과 고체 상태의 확산 저항이 회합하여 전체반응속도를 지배하며, 이때 반응속도상수는 367.67cm/min 이었고 고체상태의 확산계수는 29.66cm²/min이었다. 또한 재생반응시에 는 화학반응 저항만이 전체반응의 저항으로 관여하며, 이때의 반응속도상수는 3.45x10e cm/min이었다. In the dry-type high temprature gas desulfurization process, sulfidation and regeneration reactions of desulfrrization sorbents are noncatalytic gas-solid reactions. The mathematical modeling of noncatalytic gas-solid reactions is improtant in order to interpret laboratory data and in design and scale-up. Zinc titanate sorbent to manufacture by spray dryer is used in sulfidation and regeneration reactions of desulfuization sorbents. The result which analyzes reaction rate of sulfidation reaction by applying each reactions to modified unreacted core model is that the global reaction rate is controlled by associating with chemical reaction resistance and solid state diffusion resistance. In this case,reaction rate constant is367.67e cm/min and solid state diffusion coefficient is 29.66e cm²/min Also gloval reaction rate of regeneration reaction is controlled only by chemical reaction resistance. In this case, reaction rate constant is 3.45x10e cm/min.

      • SCISCIESCOPUSKCI등재

        Direct Deposition of CeO2 Films on Ni Metal Substrate by Chemical Vapor Deposition

        Hong, Gye Won,Lee, Young Min,Lee, Hee Gyoun,Jung, Choong Hwan 대한금속재료학회(대한금속학회) 2000 METALS AND MATERIALS International Vol.6 No.3

        Cerium dioxide thin films have been grown in-situ directly on cube textured Ni substrate by metal-organic chemical vapor deposition (MOCVD). At a lower deposition temperature of 400℃, an amorphous film was formed. The texture of crystalline CeO₂ film was changed from (200) orientation to (111) orientation when the deposition temperature was increased from 450℃ to 550℃. The growth rate was ∼40 ㎚/min and the rms surface roughness was 50 ㎚ for the CeO₂ film deposited at 450℃ for 10 min. Surface roughness of the film was increased with the development of (111) orientation. Deposited CeO₂ film showed a mixed texture of (100)$lt;001$gt; and (100)$lt;011$gt; orientation. Depending on the deposition condition, the transition from (100)$lt;001$gt; texture to (100)$lt;011$gt; orientation was observed.

      • 유아의 성별, 연령에 따른 체력 특성

        전영남,양점홍,김수진,이성민 釜山大學校 附設 體育科學硏究所 2005 體育科學硏究所 論文集 Vol.21 No.2

        The purpose of this study is to examine the characteristics of young children's fitness development in accordance with gheir gender and age, providing information necessary for an effective physical education instruction for young children's growth and development. For the purpose, this researcher selected total 257 young children from K Kindergarten located at K-gu in B Metropolitan City who consisted of 73 boys and 45 girls, both of were fully aged 4, and 83 boys and 56 girls, fully aged 5.......

      • Ether-free polymeric anion exchange materials with extremely low vanadium ion permeability and outstanding cell performance for vanadium redox flow battery (VRFB) application

        Cha, Min Suc,Jo, Sang Woo,Han, Seung Hui,Hong, Soo Hyun,So, Soonyong,Kim, Tae-Ho,Oh, Seong-Geun,Hong, Young Taik,Lee, Jang Yong Elsevier 2019 Journal of Power Sources Vol.413 No.-

        <P><B>Abstract</B></P> <P>Ether-free poly(<I>p</I>-phenylene)-based anion exchange membrane materials with outstanding vanadium ion blocking properties are reported. The synthesized ionomers with a rigid backbone structure show small dimensional variations despite the high ion exchange capacities. Among the synthesized membranes, the QPPP-2 membrane with ion exchange capacity of 2.1 meq·g<SUP>−1</SUP> exhibits high anion (OH<SUP>−</SUP>, SO<SUB>4</SUB> <SUP>2−</SUP>, and Cl<SUP>−</SUP>) conductivity. The QPPP-2 membrane shows an extremely low diffusion coefficient (2.12 × 10<SUP>−9</SUP> cm<SUP>2</SUP> min<SUP>−1</SUP>) for VO<SUP>2+</SUP>, which is much lower than that of Nafion 115 (2.88 × 10<SUP>−6</SUP> cm<SUP>2</SUP> min<SUP>−1</SUP>), indicating the vanadium ion blocking property of QPPP-2. Moreover, the chemical and operational stabilities of the membranes are investigated <I>via</I> ex situ soaking tests in 0.1 M VO<SUB>2</SUB> <SUP>+</SUP> solution and in situ operation tests for 100 cycles, respectively. The vanadium redox flow battery single cell assembled with the QPPP-2 membrane exhibits a coulombic efficiency of 99%, voltage efficiency of 87%, and energy efficiency of 86% during 100 cycles at 80 mA cm<SUP>−2</SUP>. The excellent chemical, morphological, and electrochemical properties of the QPPP-2 membrane make it suitable for use in vanadium redox flow battery.</P> <P><B>Highlights</B></P> <P> <UL> <LI> AEMs are fabricated by a Ni(0)-catalyzed cross-coupling reaction. </LI> <LI> The synthesized ionomers indicated excellent dimensional and chemical stability. </LI> <LI> Ether-free polymeric AEMs showed extremely low vanadium ion cross over. </LI> <LI> The performance of developed AEM showed high EE (87%) with high capacity retention. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>

      • Crosslinked anion exchange membranes with primary diamine-based crosslinkers for vanadium redox flow battery application

        Cha, Min Suc,Jeong, Hwan Yeop,Shin, Hee Young,Hong, Soo Hyun,Kim, Tae-Ho,Oh, Seong-Geun,Lee, Jang Yong,Hong, Young Taik Elsevier 2017 Journal of Power Sources Vol.363 No.-

        <P><B>Abstract</B></P> <P>A series of polysulfone-based crosslinked anion exchange membranes (AEMs) with primary diamine-based crosslinkers has been prepared via simple a crosslinking process as low-cost and durable membranes for vanadium redox flow batteries (VRFBs). Chloromethylated polysulfone is used as a precursor polymer for crosslinked AEMs (CAPSU-x) with different degrees of crosslinking. Among the developed AEMs, CAPSU-2.5 shows outstanding dimensional stability and anion (Cl<SUP>−</SUP>, SO<SUB>4</SUB> <SUP>2−</SUP>, and OH<SUP>−</SUP>) conductivity. Moreover, CAPSU-2.5 exhibits much lower vanadium ion permeability (2.72 × 10<SUP>−8</SUP> cm<SUP>2</SUP> min<SUP>−1</SUP>) than Nafion 115 (2.88 × 10<SUP>−6</SUP> cm<SUP>2</SUP> min<SUP>−1</SUP>), which results in an excellent coulombic efficiency of 100%. The chemical and operational stabilities of the membranes have been investigated via ex situ soaking tests in 0.1 M VO<SUB>2</SUB> <SUP>+</SUP> solution and in situ operation tests for 100 cycles, respectively. The excellent chemical, physical, and electrochemical properties of the CAPSU-2.5 membrane make it suitable for use in VRFBs.</P> <P><B>Highlights</B></P> <P> <UL> <LI> The crosslinking between polymer chains are constructed by 4,4′-diaminobenzophenone. </LI> <LI> The crosslinked AEMs were fabricated by commercial polysulfone (PSU; Udel<SUP>®</SUP> P-3500). </LI> <LI> The crosslinked AEM based on PSU indicated good chemical and dimensional stability. </LI> <LI> The performance of crosslinked AEM showed high EE (86%) with high capacity retention. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>

      • KCI등재

        정신분열병에 대한 리스페리돈의 효과 및 안정성

        이민수,김용구,김영훈,연병길,오병훈,윤도준,윤진상,이철,정희연,강병조,김광수,김동언,김명정,김상훈,김희철,나철,노승호,민경준,박기창,박두병,백기청,백인호,손봉기,손진욱,양병환,양창국,우행원,이정호,이종범,이홍식,임기영,전태연,정영조,정영철,정인과,정인원,지익성,채정호,한상익,한선호,한진희,서광윤 大韓神經精神醫學會 1998 신경정신의학 Vol.37 No.1

        연구목적 : 본 시험의 목적은 임상시험 시작전에 연구자들을 대상으로 PANSS Workshop을 통하여 PANSS, ESRS에 대한 국내에서의 표준화 작업을 구축하고 새로운 정신병 치료제인 리스페리돈의 효과와 안정성을 재확인하여 리스페리돈 사용에 대한 적정화를 이루는데 있다. 연구방법 : 1996년 4월부터 1996년 9월까지 국내 39개 대학병원 정신과에 입원중인 혹은 증상이 악화되어 입원하는 정신분열병 환자 377명을 대상으로 다시설 개방 연구를 시행하였다. 1주일간의 약물 배설기간을 가진후, 리스페리돈을 8주간 투여하였고, 기준점, 1주, 2주, 4주, 그리고 8주후에 평가되었다. 용량은 제1일에는 리스페리돈 1mg씩 1일 2회, 제2일에는 2mg씩 1일 2회, 제3∼7일에는 3mg씩 1일 2회 투여하였다. 이후 환자의 임상상태에 따라 임의로 증량할 수 있으며, 최대 일일 16mg을 초과하지 않도록 하였다. 추체외로 증상을 조절하기 위한 투약을 허용하였다. 임상증상 및 부작용의 평가는 PANSS(Positive and Negative Syndrome Scale), CGI(Clinical Global Impression) 그리고 ESRS(Extrapyramidal Symptom Rating Scale)을 사용하였다. 연구결과 : 377명중 343명(91%)이 8주간의 연구를 완결하였다. 치료 종결시점인 8주후 PANSS 총점수가 20% 이상 호전된 경우를 약물 반응군으로 정의할때, 약물반응군은 81.3%였다. 리스페리돈에 반응하는 예측인자로는 발병연령, 이전의 입원 횟수, 유병기간이 관련 있었다. 리스페리돈은 1주후부터 PANSS양성, 음성, 및 일반정신병리 점수상에 유의한 호전을 보여 효과가 빨랐다. CGI의 경우도 기준점에 비해 1주후부터 유의한 감소를 나타내었다. ESRS의 경우, 파킨슨 평가점수는 기준점과 비교해 투여 1주, 2주, 4주후 유의하게 증가되었다가 8주후 기준점과 차이가 없었다. Dystonia 평가점수는 1주후만 유의한 증가를 보였으며, dyskinesia 평가점수는 유의한 차이가 없었다. 혈압, 맥박수의 생명징후 및 일반 혈액학 검사, 생화학적 검사, 심전도 검사에서 유의한 변화는 없었다. 결 론 : 이상의 다시설 개방 임상 연구를 통해 리스페리돈은 정신분열병 환자에서 양성증상뿐만 아니라 음성증상 및 전반적인 증상에도 효과적인 것으로 사료된다. 보다 명확한 평가를 위해서는 다른 항정신병약물과의 이중맹검 연구가 필요할 것으로 생각되며, 또한 장기적 치료에 대한 평가도 함께 이루어져야 하겠다. Objective : The purpose of this study was to investigate the efficacy and safety of risperidone in the treatment of Korean schizophrenic patients. Method : This multicenter open study included 377 schizophrenic patients drawn from 39 university hospitals. After a wash-out period of 1 week, the schizophrenic patients were treated with risperidone for 8 weeks and evaluated at 5 points ; at baseline, and 1, 2, 4 and 8 weeks of treatment. The dose was increased from 2mg/day(1mg twice daily) to 6mg/day(3mg twice daily) during the first week and adjusted to a maximum of 16mg/day over the next 7 weeks according to the patient's clinical response. Medication to control extrapyramidal symptoms was permitted. The psychiatric and neurological status of the patients was assessed by PANSS, CGI, and ESRS scales. Results : 343(91%) of 377 patients completed the 8-week trial period. Clinical improvement, as defined by a 20% or more reduction in total PANSS score at end point, was shown by 81.3% of patients. The predictors of response to risperidone were associated older age, shorter duration of illness, fewer previous hospitalization. Risperidone had rapid onset of action ; a significant decrease of the total PANSS and three PANSS factor(positive, negative, general), and CGI was already noticed at the end of first week. For the ESRS, parkinsonism rating scores were significantly increased until week 4 comparing with baseline. Dystonia rating scores were significantly increased until week 1, and dyskinesia rating scores were not significantly changed during the study. Laboratory parameters including vital sign, EKG, hematological, and biochemical values showed no significant changes during the trial. Conclusions : This study suggests that risperidone is generally safe and effective against both the positive and negative symptoms in our group of patients.

      • SCOPUSKCI등재

        벤조디아제핀 수용체 영상용 양전자 방출 핵종 표지 플루마제닐 유도체 [F-18](3-(2-Fluoro)flumazenil의 합성과 생체 내 분포

        장영수,이숙자,강삼식,홍성현,이명철,이동수,정준기,정재민,조정혁 대한핵의학회 1999 핵의학 분자영상 Vol.33 No.6

        Purpose: Radiotracers that bind to the central benzodiazepine receptor are useful for the investigation of various neurological and psychiatric diseases. [C-11]Flumazenil, a benzodiazepine antagonist, is the most widely used radioligand for central benzodiazepine receptor imaging by PET. We synthesized 3-(2-[F- 18]fluoro)flumazenil, a new fluorine-18 (t1/2=110 min) labeled analogue of benzodiazepine receptor imaging agent, and evaluated in vivo for biodistribution in mice. Materials and Methods: Flumazenil (Ro 15-1788) was synthesized by a modification of the reported method. Precursor of 3-(2-[F-18]fluoro)flumazenil, the tosylated flumazenil derivative was prepared by the tosylation of the ethyl ester by ditosylethane. [F-18] labeling of tosyl substitued flumazenil precursor was performed by adding F-18 ion at 85℃ in the hot cell for 20 min. The reaction mixture was trapped by C18 cartridge, washed with 10% ethanol, and eluted by 40% ethanol. Bidistribution in mice was determined after intravenous injection Results: The total chemical yield of tosylated flumazenil derivative was ∼40%. The efficiency of labeling 3-(2-[F-18]fluoro)flumazenil was 66% with a total synthesis time of 50 min. Brain uptakes of 3-(2-[F-18]fluoro)flumazenil at 10, 30, 60 min after injection, were 2.5±0.37, 2.2±0.26, 2.1±0.11 and blood activities were 3.7±0.43, 3.3±0.07, 3.3±0.09%ID/g, respectively. Conclusion: We synthesized a tosylated flumazenil derivative which was successfully labeled with no-carrier-added F-18 by nucleophilic substitution.

      • KCI등재

        진공열간가압성형 (VHP) 법 및 압출로 제조한 SiCp/Al 및 SiCp/2024Al 복합재료의 동적탄성계수와 감쇄능 (내부마찰) : 금속기 복합재료의 동적탄성계수 및 감쇄능 측정

        김영만,조기현,이경민,홍성길 대한금속재료학회(대한금속학회) 1999 대한금속·재료학회지 Vol.37 No.9

        To shorten the processes of MMC fabrication, a number of techniques are being studied. In this study, a new process for MMC's fabrication was developed utilizing vacuum hot pressing and subsequent extrusion. MMC's with pure Al and 2024Al matrices reinforced with various volume fractions of SiC particulates were produced at 400℃ by vacuum hot pressing(VHP), followed by direct extrusion with extrusion ratios of 10:1 at 480℃ at constant ram speed of 2㎜/sec. The effects of extrusion pressure and relative density according to the volume fractions of the reinforcement were compared with the resultant metallurgical microstructures. Young's moduli of the manufactured composites were measured by the sonic resonance method, damping capacity by free decay method. Measured Young's moduli of the composites at room temperature were compared with the predictions based on Rule of Mixtures, Halpin-Tsai and Mean-field models. Measured Young's moduli of the composites are in good agreement with the predictions based on Mean-field model. The composites reinforced with finer particles showed higher damping capacity under the same amount of SiC reinforcement.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼