RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • A Basic Study on Leaf and Stem Production of Angelica acutiloba

        Choi,Seong-Kyu,Yun,Kyeong-won,Chon,Sang-Uk,Lee,Jong-Ill,Seo,Young-Nam,Seo,Kyoung-Sun,Choi,Kyeong-Ju 한국자원식물학회 2004 Plant Resources Vol.7 No.3

        This study was conducted to develop effective production system in greenhouse for leaves and stems of Angelica acutiloba by using connect pots in 2003 and 2004. Seed germination rate and plant biomass of Angelica acutiloba collected in 2004 were higher than those harvested in 2003. Germination rate of Angelica acutiloba seeds collected in 2003 was 10%, while germination rate of seeds collected in 2004 was above 90%. Especially, plant growth and yield of Angelica acutiloba grown in connect pots sized with 4×4×5cm(length×width×height) were the highest. These results indicate that leaf and stem production of Angelica acutiloba can be improved by using connect pots and optimizing seed collecting time in greenhouse.

      • KCI등재후보

        적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석

        최성아,김선호,황윤찬,윤창,오병주,최보영,정우남,정선와,황인남,오원만 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.4

        This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The heat carrier system 'System B' (Model 1005. Analytic Technologies, USA) and the Buchanan's pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infraed thermography (Radiation Thermometer-IR temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it(p<0.001). 2. When the pluggers were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3±10.5℃ to 192.1±3.3℃ in a touch for 1 sec, from 218.6±5.0℃ to 179.5±4.2℃ in a touch for 2 sec, from 197.5±3.0℃ to 167.6±3.7℃ in a touch for 3 sec, from 183.7±2.5℃ to 159.8±3.6℃ in a touch for 4 sec and from 164.9±2.0℃ to 158.4±1.8℃ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temerature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature dose not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommended, and finally a quick touch of heat control spring for 1 sec reveals the highest temperature rise.

      • 다량의 하부위장관출혈이 병발된 Vibrio vulnificus 패혈증 1예

        최주연,유진홍,한석원,이대훈,최민호,박순민,김연식,김선우,신완식,강문원,강성구 대한화학요법학회 1996 대한화학요법학회지 Vol.14 No.2

        최근 저자들은 Vibrio vulnificus 감염에 의해 패혈증 및 이차성 피부 병변을 보인 42세의 남자 환자의 치료중 하부 위장관 출혈이 병발된 1예를 경험하였기에 보고하는 바이다. We experienced a case of Vibrop vulnificus septicemia which showed an unusual manifestation such as hematochezia. The patient was a 42-year-old man with chronic liver disease. The blood and wound culture revealed the organism. During intensive care, he suffered from massive hematochezi for several days. Colonoscopy and abdominal CT showed findings suspicious of ischemic colitis. To our knowledge, this is the first unusual case of V.vulnificus infection which showed massive lower gastrointestinal bleeding.

      • 조혈모세포이식 후 발생한 주폐포자층 폐렴에 대한 고찰

        주지현,최정현,이동건,백지연,고윤호,이혜정,김세희,신호진,박윤희,박지영,김유진,신완식,김춘추 대한감염학회 2001 감염 Vol.33 No.4

        Background : Pneumocytitis cainii pneumonia (PCP) can occur in immunocompromised hosts especially such as AIDS or cancer patients. Although recent research had focused on PCP in AIDS patients, few studies have described the clinical presentations of PCP in recipients of stem cell transplantation (SCT). We evaluated the clinical manifestations of PCP in SCT patients admitted at St. Mary's hospital, Seoul, Korea. Methods : The medical records of 17 PCP patients undergoing SCT between Feb. 1998 and Feb. 2000 were reviewed. The diagnosis of PCP was confirmed through the demonstration of Pneumocytitis cainii via either cytology of brochoalveolar lavage (BAL) or histological technique of lung biopsy. CMV disease and CMV infection were confirmed by BAL culture and antigenemia respectively . Results : Seventeen patients were all recipients of allogeneic SCT and 7 of 17 patients were performed non-sibling SCT. Patients presented with symptoms including brief period (4 ∼23 days) of fever (76%), dyspnea (70%), cough (64%), and signs such as rare(58.8%), Sixteen patients (94%) had been receiving immunosuppressive agent such as cyclosporine A (64%) or Fk506 (35%) without PCP prophylaxis. Eleven patients (64%) were treated with corticosteroid with mean dose of 16 mg/day prednisolone and mean duration of 4.6 months after post-SCT period. Twelve patients were co-infected with CMV. Another co-infected miCroorganisms were Pseudomonas aeruginosa, Mycobacterium tuberculosis, herpes simplex virus, parainfluenza virus, Average duration of treatment with trimethoprim-sulfamethoxazole (TMP/SMX) was 21 ±9 days. Four patients died, and three of them were related with PCP. Conclusion : PCP developed frequently in patients who were taking immunosuppressive drug due to graft versus host disease or were not taking TMP/SMX prophylaxis. High risk patients showing fever, cough, or dyspnea should be considered to take early bronchoscopic intervention for detection of PCP. When treat for PCP, it also be considered to the possibility of coinfection such as CMV. (Korean J Infect Dis 33:273∼279, 2001)

      • KCI등재
      • Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was conducted to evaluate safety to the supporting tissues of the root while the root canal is obturated using continuous wave of condensation technique. A extracted maxillary central incisor was prepared for repeated canal obturation. After conventional access opening, working length was then established to the point 1㎜ from anatomical root apex. The root canal was prepared with GT rotary Ni-Ti file (Dentsply Maillefer, Switzerland). Five thermocouples (Onega Engineering Inc., USA) were placed at 2㎜ increments on one side beginning 1㎜ from the anatomical root apex and the other five thermocouples at 2㎜ increments on the other side beginning 2㎜ from it. For obturation, a nonstandardized medium size gutta-percha cone and a ML Buchanan plugger (Analytic technologies, USA) were selected. After drying of root canal, AH 26 root canal sealer (Dentsply Detrey, Germany) was applied on the wall of the root canal. Baseline temperature was measured on the root surface. The ML size plugger was preheated for 2seconds and then the real temperature of it was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan. The root surface temperature was recorded during obturation and it was performed ten times at each of the following temperature settings: 150℃, 200℃, 250℃ and 300℃. After completion of the temperature recording, the dentinal-cementum thickness at each sites where thermocouples were attached was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1㎜ point from the tip revealed 130.82±2.96℃, 158.00±5.26℃, 215.92±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 ㎜ from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93± 0.09℃ at 250℃ setting and 5.69± 0.15℃ at 300℃ setting. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital display of System B HeatSource.

      • KCI등재후보

        Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at 150℃, 200℃, 250℃ and 300℃ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed 130.82±2.96℃ 158.00±5.26℃, 215.93±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93±0.09℃ at 250℃ setting and 5.69±0.15℃ at 300℃ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital temperature display of System B HeatSource.

      • 컬럼형 회분건조기를 이용한 벼의 건조에 관한 연구

        변유량,최홍식,조형용,권윤중,김주봉 연세대학교 산업기술연구소 1984 논문집 Vol.16 No.1

        The vertical column batch dryer which is suitable to Korean farm was constructed and dryer performance was investigated through field test. The effect of a drying air temperature and an airflow rate on the drying rate was studied, and an empirical drying equation was established. The average drying rate of paddy were 1.6-1.8%/hr at the air temperature of 43℃ and the airflow rates of 19.4 - 24.5 CFM/ft². The differences of grain moisture content between the inner and outer layer of vertical paddy bed were 0.5 - 0.9% The effect of a drying air temperature was larger at high airflow rate. At constant temperature, the drying rate was increased as an airflow rate was increased. The empirical drying equation could be expressed as followed: ??=0.9exp(??) Where K=3.22×?? The average whitening ratio of brown rice which was dried with column batch dryer was higher 0.6% than that of sun dried rice.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼