RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Projections of summertime ozone concentration over East Asia under multiple IPCC SRES emission scenarios

        Lee, Jae-Bum,Cha, Jun-Seok,Hong, Sung-Chul,Choi, Jin-Young,Myoung, Ji-Su,Park, Rokjin J.,Woo, Jung-Hun,Ho, Changhoi,Han, Jin-Seok,Song, Chang-Keun Elsevier 2015 Atmospheric environment Vol.106 No.-

        <P><B>Abstract</B></P> <P>We have developed the Integrated Climate and Air Quality Modeling System (ICAMS) through the one-way nesting of global–regional models to examine the changes in the surface ozone concentrations over East Asia under future climate scenarios. Model simulations have been conducted for the present period of 1996–2005 to evaluate the performance of ICAMS. The simulated surface ozone concentrations reproduced the observed monthly mean concentrations at sites in East Asia with high R<SUP>2</SUP> values (0.4–0.9), indicating a successful simulation to capture both spatial and temporal variability. We then performed several model simulations with the six IPCC SRES scenarios (A2, A1B, A1FI, A1T, B1, and B2) for the next three periods, 2016–2025 (the 2020s), 2046–2055 (the 2050s), and 2091–2100 (the 2090s). The model results show that the projected changes of the annual daily mean maximum eight-hour (DM8H) surface ozone concentrations in summertime for East Asia are in the range of 2–8 ppb, −3 to 8 ppb, and −7 to 9 ppb for the 2020s, the 2050s, and the 2090s, respectively, and are primarily determined based on the emission changes of NO<SUB>x</SUB> and NMVOC. The maximum increases in the annual DM8H surface ozone and high-ozone events occur in the 2020s for all scenarios except for A2, implying that the air quality over East Asia is likely to get worse in the near future period (the 2020s) than in the far future periods (the 2050s and the 2090s). The changes in the future environment based on IPCC SRES scenarios would also influence the change in the occurrences of high-concentrations events more greatly than that of the annual DM8H surface ozone concentrations. Sensitivity simulations show that the emissions increase is the key factor in determining future regional surface ozone concentrations in the case of a developing country, China, whereas a developed country, Japan would be influenced more greatly by effects of the regional climate change than the increase in emissions.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Change in ozone level is determined by the combination of NO<SUB>x</SUB> and NMVOC emissions. </LI> <LI> Ozone level over East Asia would get worse in the near future (the 2020s) than far future. </LI> <LI> A high-concentration event generally increases and more frequently occurs in the future. </LI> <LI> Change in ozone air quality in a developing country depends more on emissions change. </LI> <LI> Change in ozone air quality in a developed country depends more on climate change. </LI> </UL> </P>

      • KCI등재

        Diagnostic Significance of Brainstem Auditory Evoked Potentials in Microvascular Decompression of Patients with Hemifacial Spasm or Trigeminal Neuralgia

        ( Sang-koo Park ),( Sung-hyuk Lim ),( Chan-woo Park ),( Jin-woo Park ),( Sung-ho Chang ),( Keun-hye Park ),( Hae-ja Park ),( Ji-hye Song ),( Dong-ok Uhm ),( Ki-bong Kim ) 대한임상검사과학회 2011 대한임상검사과학회지(KJCLS) Vol.43 No.1

        The purpose of this study was to analyse brainstem auditory evoked potentials (BAEP) wave change data during microvascular decompression (MVD). The nerve function of Cranial Nerve VIII is at risk during MVD. Intraoperative monitoring of BAEP can be a useful tool to decrease the danger of hearing loss. Between January and December 2009, 242 patients had MVD for hemifacial spasm (HFS) and trigeminal neuralgia (TN). Among intraoperative BAEP changes, amplitude of V-V’ was the most frequently observed during cerebellar retraction and decompression step of the MVD procedure. 138 patients (57%) had no BAEP change while 104 patients (42.98%) had BAEP change. 69 patients (28.5%) had Type A-I, 16 patients (6.6%) had Type A-II, 5 patients (2.1%) had Type B, and 13 patients (5.37%) had Type C. MVD is a surgical procedure to relieve the symptoms (e.g. pain, muscle twitching) caused by compression of a nerve by an artery or vein. During BAEP intraoperative monitoring, the surgical step is important in interpreting the changes of wave V. Several potential mechanisms of injury may affect the cochlear nerve, and complete loss of BAEP is often associated with postoperative hearing loss. Intraoperative BAEP monitoring may provide an early warning of hearing disturbance after MVD.

      • Effect of Changing Amniotic Fluid Osmolarity on the $Li^+$ Transport Through the Membrane Surrounding Amniotic Fluid in the Rabbit

        Chang, Jin-Keun,Lee, Sang-Jin,Sung, Ho-Kyung The Korean Physiological Society 1993 대한생리학회지 Vol.27 No.1

        To study the regulation of amniotic fluid volume and electrolyte concentration by the Membranes surrounding the amniotic fluid, the rate of $Li^+$ disappearance from amniotic sac of expired fetuses were examined while increasing the amniotic volume and osmolarity in rabbits. After intraamniotic injection of 1 ml isosmotic saline (about 20% of the amniotic fluid volume) containing 15 mM LiCl and 0.5 g/L Censored, the time courses of $Li^+$ and Censored disappearance were determined. From there the $Li^+$ clearance through the extrafetal routes was estimated and compared with that obtained from living fetuses. The volume, $Na^+$ concentration and osmolarity of amniotic fluid were measured and their relationships with $Li^+$ disappearance were evaluated. The fellowing results were obtained: 1. The rate of disappearance from amniotic fluid of living fetuses during the first 30 minutes was strikingly higher for $Li^+$ than for Censored, suggesting that extrafetal routes exist. At 60 and 90 minutes, however, the disappearance rate of $Li^+$ was less than that of Censored, suggesting the possibility of $Li^+$ reentry through fetal urination. 2. The disappearance of $Li^+$ from the amniotic fluid of the expired fetus was substantial, although lower than that of living fetuses, throughout the experimental period. 3. The $Na^+$ concentration and the osmolarity of the amniotic fluid of expired fetus measured 30 minutes after an intraamniotic injection of isoosmotic saline showed wide variation, but thereafter they changed gradually towards the normal extracellular fluid level. 4. When the amniotic fluid was iso- or hyposmolar, the rate of $Li^+$ disappearance from the amniotic fluid of the expired fetuses showed little variation. However, when the amniotic fluid was hyperosmolar, the rate at 30 minutes was markedly lower than those of isosmotic or hyposmotic amniotic fluid. At 90 minutes, the rate of $Li^+$ disappearance in hyperosmolar fluid reached a similar level to the rate in isosmolar fluid. 5. The intraamniotic injection of 400 mOsm/L saline solution decreased the disappearance rate of $Li^+$ from expired fetuses, while the injection of mannitol into the maternal vein induced no significant change. From these results it is concluded that: 1) a significant amount of $Li^+$ may leave the amniotic fluid via filtration through the membranes surrounding the amniotic fluid, 2) during hyperosmolar challenge to amniotic fluid, osmotic bulk flow might counteract the filterable loss, and 3) $Li^+$ disappearance might continue even after the volume and osmolarity of the amniotic fluid have recovered to control values.

      • Effect of Changing Amniotic Fluid Osmolarity on the Li<sup>+</sup> Transport Through the Membrane Surrounding Amniotic Fluid in the Rabbit

        Chang. Jin-Keun,Lee. Sang-Jin,Sung. Ho-Kyung 대한생리학회 1993 대한생리학회지 Vol.27 No.1

        To study the regulation of amniotic fluid volume and electrolyte concentration by the Membranes surrounding the amniotic fluid, the rate of Li<sup>+</sup> disappearance from amniotic sac of expired fetuses were examined while increasing the amniotic volume and osmolarity in rabbits. After intraamniotic injection of 1 ml isosmotic saline (about 20% of the amniotic fluid volume) containing 15 mM LiCl and 0.5 g/L Censored, the time courses of Li<sup>+</sup> and Censored disappearance were determined. From there the Li<sup>+</sup> clearance through the extrafetal routes was estimated and compared with that obtained from living fetuses. The volume, Na<sup>+</sup> concentration and osmolarity of amniotic fluid were measured and their relationships with Li<sup>+</sup> disappearance were evaluated. The fellowing results were obtained: 1. The rate of disappearance from amniotic fluid of living fetuses during the first 30 minutes was strikingly higher for Li<sup>+</sup> than for Censored, suggesting that extrafetal routes exist. At 60 and 90 minutes, however, the disappearance rate of Li<sup>+</sup> was less than that of Censored, suggesting the possibility of Li<sup>+</sup> reentry through fetal urination. 2. The disappearance of Li<sup>+</sup> from the amniotic fluid of the expired fetus was substantial, although lower than that of living fetuses, throughout the experimental period. 3. The Na<sup>+</sup> concentration and the osmolarity of the amniotic fluid of expired fetus measured 30 minutes after an intraamniotic injection of isoosmotic saline showed wide variation, but thereafter they changed gradually towards the normal extracellular fluid level. 4. When the amniotic fluid was iso- or hyposmolar, the rate of Li<sup>+</sup> disappearance from the amniotic fluid of the expired fetuses showed little variation. However, when the amniotic fluid was hyperosmolar, the rate at 30 minutes was markedly lower than those of isosmotic or hyposmotic amniotic fluid. At 90 minutes, the rate of Li<sup>+</sup> disappearance in hyperosmolar fluid reached a similar level to the rate in isosmolar fluid. 5. The intraamniotic injection of 400 mOsm/L saline solution decreased the disappearance rate of Li<sup>+</sup> from expired fetuses, while the injection of mannitol into the maternal vein induced no significant change. From these results it is concluded that: 1) a significant amount of Li<sup>+</sup> may leave the amniotic fluid via filtration through the membranes surrounding the amniotic fluid, 2) during hyperosmolar challenge to amniotic fluid, osmotic bulk flow might counteract the filterable loss, and 3) Li<sup>+</sup> disappearance might continue even after the volume and osmolarity of the amniotic fluid have recovered to control values.

      • KCI등재

        A proposal of the Optimal Angle of Standing Assistant Chair for the Elderly by Comparing of Pressure Distribution on Hip

        Sung-Ho Chang(장성호),Ji-Hoon Baek(백지훈),Jung-Eon Lee(이중언),Nematov Mirazamjon(Nematov Mirazamjon),Seok-Wan-Kang(강석완),Wang-Bum Lee(이왕범) 한국산업경영시스템학회 2018 한국산업경영시스템학회지 Vol.41 No.3

        One of the most performed action in daily life is standing up from sitting position. As the population of the world is aging at the high rates, people may face problems with reduced muscle strength as well as psychological changes. This can lead elderly people having difficulties with standing up from chair. Now, with the aging trend worldwide, products are being developed that can support the lives of the elderly. This study examines the distribution of hip pressure in relation to the seating positions of the standing assistance seats under development to prevent standing up accidents in older adults. The currently developing standing assistant chair designed to tilt to a maximum angle of 25 degrees. At over 25°, design considers that older people are at risk of thrown back out of that force and that the forces exerted on their arms and legs can be a significant burden to older people. By considering danger of higher than 25° for older people which is experimented in the basis of static capturing approach in previous papers, it is experimented people with age group of 20~60 on 0° to 25° tilting angle on the basis of dynamic capturing method in order to pick convenient angle of inclination. Moreover, tried to find the optimum angle by comparing the hip pressure distribution when seated at the edge of the seat and at the center of the seat with the pressure distribution sensor.

      • SCOPUSKCI등재
      • KCI등재

        Optimal parameter derivation for Muskingum method in consideration of lateral inflow and travel time

        Kim, Sang Ho,Kim, Ji-sung,Lee, Chang Hee 한국수자원학회 2017 한국수자원학회논문집 Vol.50 No.12

        하도홍수추적 방법에서 많이 사용되고 있는 Muskingum 방법의 가장 중요한 매개변수는 저류상수와 가중인자이다. Muskingum 방법은 상류 유입지점에서 하류 유출지점까지 측방유입량이 고려되지 않지만, 실제 유역에는 강우로 인하여 측방유입유량이 발생한다. 이로 인해 상하류 실측 자료를 이용하여 저류상수 및 가중인자를 산정하는 것이 매우 어려운 상황이다. 이에 본 연구는 HEC-RAS 1차원 부정류 해석모형을 이용한 수리학 적 홍수추적을 통해 측방유입유량이 제외된 상태에서의 하도에서 전파되는 유량을 산정하였고, 이를 이용하여 저류상수 및 가중인자를 산정하는 방법을 제시하였다. 이와 함께 저류상수가 유하시간과 관계있음을 감안하여 국내 하천기본계획 수립 시 사용되는 유하시간 경험 공식들을 저류상수로 적용한 결과를 비교 분석하였다. 마지막으로 유량이 고려된 유하시간 산정식을 개발하고, 유입량의 변화에 맞춰 유하시간을 업데이트하여 모의를 수행하는 방법을 제시하였다. 유량을 고려한 유하시간을 저류상수로 적용한 경우, 유량의 상승 및 하강 과정, 첨두 유량, 그리고 첨두 시간에 대해서 잘 모의하는 것으로 분석되었다. The most important parameters of the Muskingum method, widely used in hydrologic river routing, are the storage coefficient and the weighting factor. The Muskingum method does not consider the lateral inflow from the upstream to the downstream, but the lateral inflow actually occurs due to the rainfall on the watershed. As a result, it is very difficult to estimate the storage coefficient and the weighting factor by using the actual data of upstream and downstream. In this study, the flow without the lateral inflow was calculated from the river flow through the hydraulic flood routing by using the HEC-RAS one-dimensional unsteady flow model, and the method of the storage coefficient and the weighting factor calculation is presented. Considering that the storage coefficient relates to the travel time, the empirical travel time formulas used in the establishment of the domestic river basin plan were applied as the storage coefficient, and the simulation results were compared and analyzed. Finally, we have developed a formula for calculating the travel time considering the flow rate, and proposed a method to perform flood routing by updating the travel time according to the inflow change. The rise and fall process of the flow rate, the peak flow rate, and the peak time are well simulated when the travel time in consideration of the flow rate is applied as the storage coefficient.

      • SCOPUSSCIEKCI등재

        요추부 추간판탈출증에서 경피적 자동수핵제거술 치료의 예후 인자

        이승호,문창택,장상근 대한신경외과학회 1994 Journal of Korean neurosurgical society Vol.23 No.12

        Percutaneous automated lumbar discectomy as it is now practiced appears to be an extremely safe procedure. One hundred fourty eight patients with lumbar disc herniation were treated with automated percutaneous lumbar discectomy(A.PL.D.). The postoperative results in 118 patients were evaluated at more than 3 months after the operation. Total satisfactory result was 74% excellent 16%, good 58%, fair 22%, poor 4% by Macnab' s criteria. For further satisfactory result, more meticulous crteria is needed. The results indicated that several prognostic factors were considered : 1) less than 30 years of age, 2) more than 4ml of aspirated disc volumn, 3) L4-5 of disc level, 4) follow up X-ray change(59%), but no CT change and possible MRI change.

      • Rat의 복강내에 투여한 5-fluorouracil-polyglycolic acid 제형이 장기에 미치는 영향에 관한 연구

        강대영,송규상,최정목,노승무,정경수,오정연,김진향,양준묵,최선웅,이진호,조준식,민병무,김용백,김창식,박근성,김승영,김학용,인현빈 충남대학교 의과대학 지역사회의학연구소 1998 충남의대잡지 Vol.25 No.1

        For more effective intraperitoneal chemotherapy, the authers made 5-fluorouracil-polyglycolic acid composite disks(FU-PGA disks) with 5-fluorouracil and polyglycolic acid, a biodegradable polymer. We inserted the FU-PGA disk into the peritoneal cavites of Sprague-Dawley male rats, the control and three experimental groups; one FU-PGA disk insert group(300mg/kg), two FU-PGA disk insert group(600mg/kg), and three FU-PGA disk insert group(900mg/kg). The control group received a similar number of PGA disk inserts. A pharmacokinetic study was performed to measure the 5-fluorouracil concentration in the peritoneal fluid, blood, and tissues(liver, kidney and heart) at 24 hours, 72hours and 168 hours after insertion of the FU-PGA disk. Light and electron microscopic studies were done. The results were as follows: 1) The number of white blood cells and platelets decreased after FU-PGA insertion. The degree was proportional to the duration and amounts inserted. The change in the number of red blood cells varied slightly. 2) Light microscopically, slight changes were noted at 168 hours in the 3 disk insert group (900mg/kg). Mild fatty change and hepatocyte degeneration around the central veins of the liver were noted, with vacuolar degeneration in the proximal convoluted tubules of the kidney. 3) Electron microscopically,the liver showed focal increases of lipid droplets in the hepatocytes, and irregular nuclear membrane with focal nucleolar segregation of the fibrillar and granular elements. Also the double membranous structure of the hepatocytes and Kupffer cells was widened with bleb formation. The kidney showed wide separation of the nuclear double membrane in the proximal convoluted tubular cells and mesangial cells, with vacuolation and myelin figure formation in the mitochondria of the proximal convoluted tubular cells, at 72 hours and 168 hours in the 2 to 3 FU-PGA insert groups. The heart showed focal loss of cristae,vacuolation and myelin figure formation in the mitochondria of the 2 to 3 FU-PGA insert groups. In conclusion, despite the large amont of FU-PGA inserted, the histopathological changes in the liver, kidney and heart were slight, and consonant with the very low amount of 5-fluorouracil concentrations detected in the liver, kidney and heart. The above results suggest that the FU-PGA composite can serve as a new device for releasing drugs in a controlled manner and easily targeted to intraperitoneal organs. This device can improve the efficacy of intraperitoneal chemotherapy for gastric cancer.

      • SCOPUSSCIEKCI등재

        재생 과정이 니켈-티타늄 호선의 물리적 성질과 표면 거칠기에 미치는 영향

        이성호,장영일 대한치과교정학회 2000 대한치과교정학회지 Vol.30 No.4

        본 연구의 목적은 재생된 니켈-티타늄 호선의 인장물성, 표면거칠기와 마찰력의 변화를 조사하여, 임상적으로 니켈-티타늄 호선을 재생하여 사용하는 것이 타당한지를 알아보는 것이다. 수종의 니켈-티타늄 호선과 스테인레스 스틸 호선을 처리전(T0: 대조군)과 인공타액에 4주간 처리한 군(T1), 그리고 인공타액 처리후 가압증기 멸균소독한 군(T2)으로 구분하여 인장실험과 주사전자현미경, 3D profilogram을 통한 표면거칠기의 변화와 마찰계수의 변화를 관찰하여 다음과 같은 결과를 얻었다. 1.인장실험을 하여 최대인장강도, 연신율, 탄성계수를 관찰한 결과 모든 니켈-티타늄 호선에서 재생과정 후에 대조군과 유의한 차이를 보이지 않았다(p〈0.05). 단 스테인레스 스틸 호선은 재생과정 후에 최대인장강도, 연신율, 탄성계수에서 통계적으로 유의한 변화를 보였다(p〈0.05). 2.주사전자현미경을 통한 관찰에서 재생후에 Sentalloy를 제외한 호선에서 표면의 점부식(pitting)과 압흔(indentation)이 증가하였다. 3.3D profilogram을 사용하여 관찰한 표면거칠기(Ra와 Rq)의 변화를 살펴보면, 재생과정 후에 Sentalloy를 제외한 NiTi, Optimalloy, 스테인레스 스틸 호선에서 통계적으로 유의하게 표면거칠기가 증가하였다(p〈0.05). 4.재생과정 후에 시행한 마찰력 실험에서는 최대운동마찰계수가 Sentalloy를 제외한 NiTi, Optimalloy, 스테인레스 스틸 호선에서 통계적으로 유의하게 증가하였다(p〈0.05). NiTi, Optimalloy의 표면거칠기와 마찰계수의 변화는 임상적으로 영향을 미칠 정도는 아니며, 결과적으로 니켈-티타늄 호선을 재생하면, 인장실험시의 물성과 표면거칠기, 마찰계수의 변화가 임상적으로 문제가 없을 것으로 생각된다. The purpose of this study was to investigate the change of mechanical properties, surface topography and frictional force of various nickel titanium wires after recycling. Three types of nickel-titanium wires and one type of stainless steel wire were divided to three groups: as-received condition(T0:control group), treated in artificial saliva for four weeks(T1) and autoclaved after being treated in artificial saliva(T2). Some changes were observed for the selected mechanical properties in tensile test, surface topography by means of SEM and 3D profilogram, and frictional coefficient. The findings suggest that: 1.Nickel-titanium wires demonstrated no statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity, but stainless steel wore demonstrated statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity between the groups(p〈0.05). 2.NiTi, Optimalloy, Stainless Steel wires demonstrated increased pitting and corrosion in SEM finding. 3.Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater surface roughness(Ra and Rq) through 3D profilogram when compared with the control wires(p〈0.05), but Sentalloy didn't demonstrate significant difference. 4.Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater maximum frictional coefficient when compared with the control wires(P〈0.05), but Sentalloy didn't demonstrate significant difference. The changes of surface roughness and frictional coefficient in NiTi and Optimalloy had no clinical implication, Consequently recycled nickel titanium wires demonstrated no clinical problem in tensile properties, surface topography and frictional coefficient.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼