http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
한의진단명과 진단요건의 표준화 연구 II (표준화 실례) : 2차년도 연구결과 중간 보고
양기상,최선미,최승훈,안규석,박경모,박종현,김성우,신승호,정우열,전병훈,고현,김정범,신상우,김성훈,김동희,권영규,엄현섭,장혜옥 한국한의학연구원 1996 한국한의학연구원논문집 Vol.2 No.1
The diagnostic requirements were suggested and explained regarding the systems of differentiation of symptoms and signs in the second year study of standardization and unification of the terms and conditions used for diagnosis in oriental medicine. The systems were as follows; - differential diagnosis according to condition of body fluid, differentiation of syndromes according to the state of qi and blood, differential diagnosis according to relative excessiveness or deficiency of yin and yang(氣血陰陽津液辨證) - differentiation of diseases according to pathological changes of the viscera and their interrelation - analyzing and differentiating of febrile diseases in accordance with the theory of the six channels(傷寒辨證) The individual diagnosis pattern was arranged by the diagnostic requirements in the following order : another name(異名), notion of diagnosis pattern, index of differentiation of symptoms and signs(辨證指標), the main point of diagnosis, analysis of diagnosis pattern(證候分析), discrimination of diagnosis pattern(證候鑑別), a way of curing a diseases(治法), prescription(處方), herb in common use(常用藥物), diseases appearing the diagnosis pattern(常見疾病), documents(文獻調査). This study was carried out on the basis of the Chinese documents and references.
신민철,윤옥병,오승환,김여갑,이상철,신민철 大韓顎顔面成形再建外科學會 1996 Maxillofacial Plastic Reconstructive Surgery Vol.18 No.1
Mucoepidermoid carcinomas, first reported by Volkman(1895), form 6% to 9% of all salivary tumors. Two thirds affecting the parotid gland and the remaining third, the minor glands. As we could know from its name, mucoepidermoid carcinomas originate from ductal epithelium including squamous, mucous-secreting, and undifferentiated intermediate cells. Histologically, it is classified as well-differentiated (low grade), moderately-differentiated(intermediate grade), and poorly-differentiated (high grade) types and the treatment method and prognosis are influenced from its histological grade. We have experienced two cases of mucoepidermoid carcinoma treated surgically with good results and now would like to report these with review of literatures.
고주파수대역에 적용되는 Fe-( BN, Si₃N₄)박막의 미세구조와 자기적특성에 관한 연구
申東勳,張勝彦,李宰源,南勝義 弘益大學校 科學技術硏究所 1997 科學技術硏究論文集 Vol.8 No.-
We have investigated the magnetic properties of FeBN thin films deposited by using RF magnetron sputtering and Fe-BN composite target. It was investigated that the area fraction of BN chips on the Fe target and partial pressure of nitrogen was the main factors influencing the soft magnetic properties and resistivity of FeBN thin film. The low addition of N₂increases significantly the soft magnetic properties and electrical resistivity. The good soft magnetic properties are obtained at N₂partial pressure of 5%, but futher increase in N₂ partial pressure degrade the soft magnetic properties due to formation of nitrides such as Fe₄N, Fe₂∼₃N. In a sputtering process, as the area fraction of BN increases, FeBN thin films fabricated at the area fraction of 0.25 exhibt soft magnetic properties (Bs∼17kG, Hc∼10e, μ∼1000).
지로용지 영상의 실시간 압축 및 인식처리를 위한 하드웨어 설계 및 구현
신동욱,오승환 한국기술교육대학교 2001 論文集 Vol.8 No.1
ABSTRACT In this paper, we proposed the algorithms for real time compression and recognition of giro paper image data which is serially inputted by 1 bit unit. Those algorithms are designed and implemented with PLD, and their propriety is confirmed.
신동욱,강승찬 한국기술교육대학교 2000 論文集 Vol.7 No.1
This paper presents the lamp control system in underground parking place. The control system consists of lamp control modules and monitoring module which are connected by RS-485 communication bus. The lamp control modules are controlled through a user command within the monitoring module, sense a movement detector and turn lamps in underground parking place on or off. The monitoring module displays status values of On or Off received from lamp control modules. The system is an efficient lighting control system to meet today's demand for highly flexible and energy saving lighting solutions.
신승수,신동화,지홍일,최승권,조용환 충북대학교 산업과학기술연구소 2002 산업과학기술연구 논문집 Vol.16 No.1
The Binary Scheduling Wheel(BSW) algorithm was proposed to carry on manage buffer efficiently at implementing of WRR scheduler. But, BSW algorithm cause serous performance degradation of cell delay and maximum queue length because it allocates more weight than the weight allocated actually in VC and could not serve cell if the VC queue is empty. In this paper, we propose new BSW of the old BSW structure. Also, we develop a cell scheduling algorithm which is suitable for the new BSW structure. The proposed BSW structure and the developed algorithm are capable of maintaining the allocated weight of each VC correctly, and decrease average cell delay and average buffer length by serving other VC cell when the selected VC queue is empty, and increase cell service ratio as a whole. The evaluation results show that the proposed structure can implement WRR algorithm more efficiently than the old BSW.
(Shin Taek Oh),(In Gang Jang),(Sung Wook Kim),(Baik Kee Cho),(Seung Dong Lee) 대한피부과학회 2002 Annals of Dermatology Vol.14 No.1
N/A Hobnail hemangioma(HH)is a benign acquired vascular tumor of endothelial origin which should be differentiated from other malignant vascular neoplasm such as Kaposi`s sarcoma or angiosarcoma.We report a case of hobnail hemangioma in a 21-year-old woman who had a dusky-red patch on her left shin.Histologically,ectatic vascular channels with a single layer of plumped endothelial cells were seen and the vascular channels seemed to dissect the collagen bundles.She underwent treatment with surgical excision with primary closure. (Ann Dermatol 14(1)45-47, 2002).
신용섭,송승훈,곽동주 慶星大學校 1998 論文集 Vol.19 No.2
In this study, the characteristics of CO₂conversion and glow discharge were investigated using glow discharge plasma reactor with a parallel copper electrode system. A pure CO₂ gas was used for the carrier gas under gas pressure of 10∼80 torr in a glow discharge. For glow discharge, discharge current was increased with the increase of discharge voltage. In the case of constant discharge voltage, the discharge current tend to increase with the decreasing of gas pressure. Using pure CO₂only, the CO₂conversion was increased with the increase of discharge power and the decreased of gas pressure. The maximum CO₂ conversion was 28% at 10 torr, 598 W, 902.4V. Energy yield was decreased with the increase of discharge power and discharge voltage. Also, the concentrations of CO₂and O₂in the produced gas were slightly increased with the increase of CO₂ conversion.
하악골 전돌증 수술 후 하악골 이동량에 따른 발음 양상에 관한 비교 연구
신기영,이동근,오승환,성헌모,이숙향 대한악안면성형재건외과학회 2001 Maxillofacial Plastic Reconstructive Surgery Vol.23 No.1
After performing mandibular setback surgery, we found some changes in patterns and organs of speech. This investigation was undertaken to investigate the aspect and degree of speech patterns according to the amount of surgical setback in mandibular prognathic patients. Thirteen patients with skeletal Class Ⅲ malocclusion were studied preoperative and postoperative over 6 months. They had undergone the mandible setback operation via bilateral sagittal split ramus osteotomy(BSSRO). We split the patients into two groups. Group 1 included patients whose degree of mandibular setback was 6mm or less, and Group 2 above 6mm. Control group was two adults wish normal speech patterns. A phonetician performed narrow phonetic transcriptions of tape-recorded words and sen- tences produced by each of the patients and the acoustic characteristics of the plosives, fricatives, and flaps were analyzed with a phonetic computer program (Computerized Speech Lab(CSL) Model 4300B(USA) ). The results are as fallows : 1. Genera1ly, Patients showed longer closure duration of plosives, shorter VOT(voice onset time) and higher ratio of closure duration against VOT 2. Patients showed more frequent diffuse distribution than the control group in frication noise energy of fricatives. 3. In fricatives, frequency of compact from were higher in group 1 than in group 2. 4. Generally, a short duraction of closure for /ㄹ/ was not realized in the patient's flaps. Instead, it was realized as fricatives, sonorant with a vowel-like formant structure, or trill type consonant. 5. Abnormality of the patient's articulation was reduced, but adaptation of their articulation after surgery was not perfect and the degree of adaptation was different according to the degree of surgical setback.