RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

        Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

        Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

      • KCI등재

        가열 조건을 달리한 단호박 페이스트와 검 종류별 단호박 라떼의 품질특성

        박보람,김나정,유선미,한귀정,김하윤,한혜민,신동선,신말식,Park, Bo-ram,Kim, Na-Jung,Yoo, Seon-Mi,Han, Gwi Jung,Kim, Ha Yoon,Han, Hye-min,Shin, Dong-Sun,Shin, Malshick 한국식품조리과학회 2015 한국식품조리과학회지 Vol.31 No.3

        가열 조건에 따른 단호박 페이스트를 제조하기 위해, 단호박을 15분 간 초벌 증숙한 뒤, 고압가열 처리 0분(A), 10분(B), 20분(C), 40분(D) 실시하여 실험군의 품질특성 을 조사하였다. 그 결과 일반성분의 경우, 대체적으로 고 압가열 처리 유무에 따른 유의적 차이가 관찰되었으며, 고압가열 처리한 B, C, D 실험군의 수분함량, 조단백질, 조섬유가 고압가열 무처리군 A에 비해 감소하였고, 가용성 무질소물은 증가하는 것으로 나타났다. 가열 조건별 단호박 페이스트의 수용성식이섬유는 고압가열 20분 처리군인 C의 측정치가 2.02로 가장 높았으며 무처리군인 A의 1.60 보다 증가하였고, 고압가열 처리 40분의 경우 오히려 감소하는 것으로 나타났다. 색도의 L 값은 고압가열 무처리군인 A가 52.20에서 고압가열 처리 10분, 20분, 40분으로 시간이 증가함에 따라 각각 50.33, 49.46, 48.06으로 감소하였고, a 값과 b 값 또한 유의적인 차이를 보이며 감소하였다. 현미경을 통한 단호박 페이스트의 현탁액 입자를 관찰한 결과 카로티노이드를 포함하는 유세포가 관찰되었으며 고압가열 처리와 그 시간이 증가함에 따라 단호박 유세포의 변형이 뚜렷하게 관찰되었으나, 부유안정성 실험 결과 실험군 A, B, C, D 간 차이가 없었다. 이때, 가열조건의 선택은 수용성 식이섬유의 증가, 환원당 증가, 단맛의 관능특성이 유의적으로 높고, 전반적 기호도가 가장 우수한 것으로 나타난 고압가열 처리 20분인 C 실험군으로 결정하였다. 선택된 조건의 단호박 페이스트에 식품가공 시 널리 사용되는 검류인 xanthan gum, locust bean gum, guar gum을 단호박 페이스트에 종류별로 첨가하여 부유안정성을 확인하였는데, 이 결과 guar gum, locust bean gum, xanthan gum 순으로 부유안정성 효과를 나타냈으며 locust bean gum과 xanathan gum은 비슷한 정도의 효과를 보였다. 또한 관능검사를 통한 기호도 확인 결과 텍스쳐와, 전반적인 기호도가 가장 우수했으므로 locust bean gum(0.2%) 첨가 단호박 라떼의 품질이 가장 적절할 것으로 판단된다. For the production of pumpkin paste with respect to heating conditions, we steamed the pumpkin for roughly 15 min, heated it with high pressure treatment for 0 min (A), 10 min (B), 20 min (C), 40 min (D), and subsequently investigated the quality characteristics. Generally a significant difference was observed between the pumpkin paste treated with and without high-pressure heat. The values of water content, crude protein and crude fiber of the high-pressure heat-treated groups B, C, D were decreased compared with untreated group A. The soluble fiber in experimental group B sweet-pumpkin paste treated with high-pressure heat for 20 min was higher than the control, and the highest value at 2.02. Experimental group D sweet-pumpkin paste treated with high-pressure heat for 40 min was found to have a decreased soluble fiber content relative to the control. The L value for the color of the group A untreated control sweet-pumpkin paste (no high-pressure heating) decreased as the time increased from 10 min to 40 min, with L values of 50.33, 49.46, and 48.06, respectively. The b value for the color of the sweet-pumpkin paste also decreased, showing a significant difference. Taking into account all the results, we chose experimental group B in order to prepare sweet-pumpkin latte. We used 0.2% gum (xanthan gum, locust bean gum, guar gum) as a stabilizer. Sweet-pumpkin latte with xanthan and locust bean gum has a suspension stability effect that lasts 90 min. The L and b values of sweet-pumpkin latte with gums increase and a value decrease compared with the control. In terms of the overall acceptance of the sweet-pumpkin latte, the experimental group with xanthan gum scored the best.

      • SCIEKCI등재

        Disruption of rsmA Gene of Pectobacterium carotovorum subsp. carotovorum LY34 and Effect on Pathogenicity

        Kim, Min Keun,Kang, Tae Ho,Kim, Sung Kyum,Jeong, Yu Seok,Yun, Han Dae,Kim, Hoon The Korean Society for Applied Biological Chemistr 2012 Applied Biological Chemistry (Appl Biol Chem) Vol.55 No.6

        The rsmA gene was cloned from soft-rot bacterium Pectobacterium carotovorum subsp. carotovorum LY34 (Pcc LY34), and its role in pathogenicity was investigated by marker exchange mutagenesis. From a cosmid library of Pcc LY34 genomic DNA, a positive clone carrying the rsmA gene was selected, and the gene was cloned by polymerase chain reaction (PCR) amplification. The gene is 186 bp in size and encodes a protein of 62 amino acids with a predicted molecular mass of 6,839 Da. The calculated pI of the RsmA is 8.16. The phylogenetic tree showed that the RsmA of Pcc LY34 appeared genetically identical to the CsrA of Pectobacterium atrosepticum SCRI1043 (100% identity) and similar to the CsrA of Yersinia pestis KIM10+(98.3%). The gene was disrupted by the $Km^r$ gene, and the cells became mutated (i.e., $RsmA^-$ mutant). The pathogenicity test revealed that the disease rating of the $RsmA^-$ mutant only differed slightly from that of the wild type on a slice of potato tuber and a Chinese cabbage stalk. These results suggest that RsmA is not an essential factor for the pathogenicity of Pcc LY34 and that the rsmA gene of Pcc LY34 is not completely derepressed in the $RsmA^-$ mutant for virulence-related genes, contrary to the results of Erwinia carotovora subsp. carotovora $RsmA^-$ mutant, which proved hypervirulent for celery petioles. These results showed that the microenvironmental conditions of the host and/or strain of pathogen are important for the coordination of virulence gene expression.

      • The effects of secondary task on the control of vehicle under driving simulator: a study among 50s taxi drivers

        Han Soo Kim,Jin Seung Choi,Dong Won Kang,Hong Won Yeon,Mi Hyun Choi,Doo Hwan Ji,Byung Chan Min,Soon Cheol Chung,Gye Rae Tack 대한인간공학회 2011 대한인간공학회 학술대회논문집 Vol.2011 No.5

        Objective: The aim of this study is to quantitatively evaluate the effects of the secondary task during simulated driving using the variable indicating control of vehicle. Background: There are so many researches for simulated driving and performance. For instance, some researches show that the effects of cell phone conversations on simulated driving. Cell phone conversations impaired explicit recognition memory. Method: Participants included 50s taxi drivers; 15 males and 15 females. All subjects were instructed to keep a distance (30m) from the car ahead and a constant speed (80km/hr or 100km/hr). Sending text message (STM) and Searching navigation (SN) were selected as the secondary task. Experiment consisted of rest for 3min., driving alone for 1min. and driving with secondary task for 1 min.. We were analyzed anterior-posterior coefficient of variation (APCV) and medial-lateral coefficient of variation (MLCV). Results: APCV was increased by 175.4% in STM and 223.8% in SN at 80km/hr. MLCV was increased by 242.3% in STM and 323.4% in SN at 100km/hr. There was no significant difference between genders. Conclusion: Consequently, performing secondary task during driving impaired the control of vehicle.

      • KCI등재

        워크스테이션의 조명성능 평가에 관한 연구

        김영민,김한성,김창성,김강수 대한건축학회 2003 대한건축학회논문집 Vol.19 No.10

        The purpose of this study was to provide the visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0×11.6×3m) was used for the actual test. The results of this study were as follows; 1) When the indirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) The results show that the straddled layout has higher light levels (higher light ratio (%)) and the centered layout condition has lower light levels (lower light ratio (%)) in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and centered layouts have lower uniformity.

      • Photovoltaic properties of TiO2-based solar cells with sodium ethanesulfonate-modified photoelectrodes

        Kim, Sun Jie,Kim, Wook Hyun,Lee, Chang-Hyun,Kim, Hwa-Min,Kang, Cheon Su,Han, Yoon Soo Informa UK (TaylorFrancis) 2017 MOLECULAR CRYSTALS AND LIQUID CRYSTALS - Vol.651 No.1

        <P>Effects of sodium ethanesulfonate (SES) adsorbed on photoelectrode surface on the performance of dye-sensitized solar cells (DSSCs) was investigated. SES-modified photoelectrode was prepared by soaking the TiO2 film to an aqueous SES solution for 20 min. The DSSC with SES-modified TiO2 layer showed an increase in open circuit voltage (V-oc), short circuit current (J(sc)) and fill factor (FF), resulting in a power conversion efficiency of 11.20%, compared to that of reference device with bare TiO2 (10.21%). Electrochemical impedance spectroscopy and open circuit voltage decay measurements revealed that the SES modification of TiO2 surface led to a longer electron lifetime by the suppression of the interfacial charge recombination between photo-injected electrons and I-3(-) ions, resulting in an increase in J(sc) and V-oc, compared with those of a reference device without surface modification.</P>

      • 자동설계 프로그램을 이용한 비구면 렌즈의 가공 및 검증에 관한 연구

        김수용,한민식,김세민,김태호,전언찬 한국공작기계학회 2005 한국공작기계학회 춘계학술대회논문집 Vol.2005 No.-

        An aspheric lens is one of a key point optical element in the optical industry. The feature of an aspheric lens is not to have the spherical aberration. An aspheric lens is also essential element for high-precision and light-weight in the optical machine. Generally it have been used in a tailor progression an aspheric lens modelling much. In this study we applied a lay back-tracer using a index of refraction to draw a creative aspheric lens. Also we developed the automatic design program for aspheric lens. We manufactured the aspheric lens and executed a comparison experiment for refraction situation of shape and straightness experiment to inspect the drawn aspheric lens in this study.

      • KCI등재

        하지 분절 각도에 따른 수의 등척성 수축(MVIC)시 근전도 비교

        김정자,이민형,김연정,채원식,한윤수,권선옥 한국운동역학회 2005 한국운동역학회지 Vol.15 No.1

        J. J. KIM, M. H. LEE, Y. J. KIM, W. S. CHAE, Y. S. HAN, O. KWON. Comparison of the maximum EMG levels recorded in maximum effort isometric contractions at five different knee flexion angles. Korean Journal of Sport Biomechanics, Vol. 15, No. 1, pp. 197-206, 2005. The purpose of this study was to quantify the maximum EMG levels and determine if there are differences in these EMG levels with respect to different knee flexion angles. Eight university students with no known musculoskeletal disorders were recruited as the participants. The maximum voluntary isometric knee extensions and flexions were taken from each participant sat on the isokinetic exercise machine (Cybex 340) at five different knee flexion angles (10?30?50?70? 90?. After surface electrodes were attached to rectus femoris, vastus medialis, vastus laterlis, biceps femoris, and semitendinosus, maximum EMG levels at five different knee flexion angles were measured. The results showed that there was no significant difference in maximum EMG levels among five different knee flexion angles. Although there was no significant difference in EMG levels and were some variations among different knee flexion angles, the EMG signals of quadriceps in extension and biceps femoris in flexion were the greatest at 30? It seems that different joint angles or relative locations of body segments might affect the magnitude of EMG levels. Because the maximum EMG levels could change with a different knee flexion angle, an attempt should be made to more accurately measure these values. If then, %MVIC measure provides more reliable data and is most appropriate for EMG normalization.

      • A chemically regenerative redox fuel cell using (2,2,6,6-tetramethylpiperidin-1-yl)oxyl redox reaction in acid medium

        Han, Sang-Beom,Kwak, Da-Hee,Park, Hyun Suk,Park, Jin-Young,Ma, Kyeng-Bae,Won, Ji-Eun,Kim, Do-Hyoung,Kim, Min-Cheol,Park, Kyung-Won Elsevier 2018 Journal of Power Sources Vol.393 No.-

        <P><B>Abstract</B></P> <P>(2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO) with no free radical and non-volatile characteristic can be utilized as a liquid catalyst instead of O<SUB>2</SUB> at the cathode in a chemical regenerative redox fuel cell with H<SUB>2</SUB> as a fuel at the anode. In this study, the electrochemical properties and performance of TEMPO dissolved in sulfuric acid solution are investigated using half and unit cells. In the half-cell, TEMPO shows an activation energy of 1.27 kcal mol<SUP>−1</SUP> K<SUP>−1</SUP> for the reduction. A chemical regenerative redox fuel cell (CRRFC) using TEMPO as the liquid catalyst exhibits an open circuit voltage of 0.7 V and a maximum power density of 90 mW cm<SUP>−2</SUP> at 30 °C with a low activation loss. The regeneration cycling test of the CRRFC is performed at a constant voltage of 0.4 V under a flow rate of the oxygen-bubbled TEMPO solution. The performance of the CRRFC deteriorates, i.e., a power density of zero measured at >200 min. Thus, a highly efficient regeneration system needs to be developed for a high-performance CRRFC using TEMPO used as a liquid-type oxidant. Furthermore, stable liquid oxidants with relatively high standard reduction potentials can be proposed through various organic compounds.</P> <P><B>Highlights</B></P> <P> <UL> <LI> CRRFC was proposed using TEMPO instead of O<SUB>2</SUB> at the cathode. </LI> <LI> TEMPO showed fairly fast transport and low activation energy for the reduction. </LI> <LI> CRRFC exhibited an open circuit voltage of ∼0.7 V at 30 °C. </LI> <LI> CRRFC exhibited a maximum power density of ∼90 mW cm<SUP>−2</SUP> at 30 °C. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼