RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Immersion Ultrasonography of Excised Nonpalpable Breast Lesion Specimens after Ultrasound-Guided Needle Localization

        이기열,서보경,이안,제보경,조규란,우옥희,김미영,차상훈,김영식,손길수,김영수 대한영상의학회 2008 Korean Journal of Radiology Vol.9 No.4

        Objective: Ultrasound-guided needle localization has been used prior to the surgical excision of nonpalpable breast lesions. The aim of the study was to assess the feasibility of the use of a saline immersion specimen ultrasound technique (immersion-US) to confirm the successful removal of breast lesions. Materials and Methods: The devised immersion-US technique was used to examine the excised tissues of 72 ultrasound-guided needle localized breast lesions of 58 patients (34 benign lesions, 30 high-risk lesions and 8 malignant lesions). Freshly excised specimens were placed in a container filled with saline and one radiologist scanned the surgically excised specimens using a high-frequency linear transducer. We evaluated successful lesion removal and the qualities of the immersion-US images. Miss rates were determined by the use of postoperative ultrasound during follow-up. Results: All 72 lesions were identified by the use of immersion-US and satisfactory or excellent quality images were obtained for most lesions (70/72, 97%). Five (7%) lesions were initially identified as incompletely excised, based on the immersion-US findings, and prompt re-excision was undertaken. Follow-up ultrasound examinations showed no residual mass in the surgical field in any patient. Conclusion: The immersion-US technique was found straightforward and efficient to perform. Immersion-US was able to determine whether nonpalpable breast lesions had been successfully excised after ultrasound-guided needle localization. Objective: Ultrasound-guided needle localization has been used prior to the surgical excision of nonpalpable breast lesions. The aim of the study was to assess the feasibility of the use of a saline immersion specimen ultrasound technique (immersion-US) to confirm the successful removal of breast lesions. Materials and Methods: The devised immersion-US technique was used to examine the excised tissues of 72 ultrasound-guided needle localized breast lesions of 58 patients (34 benign lesions, 30 high-risk lesions and 8 malignant lesions). Freshly excised specimens were placed in a container filled with saline and one radiologist scanned the surgically excised specimens using a high-frequency linear transducer. We evaluated successful lesion removal and the qualities of the immersion-US images. Miss rates were determined by the use of postoperative ultrasound during follow-up. Results: All 72 lesions were identified by the use of immersion-US and satisfactory or excellent quality images were obtained for most lesions (70/72, 97%). Five (7%) lesions were initially identified as incompletely excised, based on the immersion-US findings, and prompt re-excision was undertaken. Follow-up ultrasound examinations showed no residual mass in the surgical field in any patient. Conclusion: The immersion-US technique was found straightforward and efficient to perform. Immersion-US was able to determine whether nonpalpable breast lesions had been successfully excised after ultrasound-guided needle localization.

      • KCI등재

        Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

        김동욱,김기남,노명호 대한영상의학회 2009 Korean Journal of Radiology Vol.10 No.5

        Objective: This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. Materials and Methods: A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). Results: The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was administered. Four patients had an equivalent pain score for both treatments. This finding was also statistically significant (p = 0.001). Conclusion: In our study, patient pain scales were significantly lower when no local anesthesia was used prior to US-FNABs of thyroid nodules as compared to when local anesthesia was administered. Therefore, we believe that when one needle puncture is used, US-FNAB should be performed without administering local anesthesia. Objective: This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. Materials and Methods: A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). Results: The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was administered. Four patients had an equivalent pain score for both treatments. This finding was also statistically significant (p = 0.001). Conclusion: In our study, patient pain scales were significantly lower when no local anesthesia was used prior to US-FNABs of thyroid nodules as compared to when local anesthesia was administered. Therefore, we believe that when one needle puncture is used, US-FNAB should be performed without administering local anesthesia.

      • KCI등재

        Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules Smaller Than 5 mm in the Maximum Diameter: Assessment of Efficacy and Pathological Findings

        김동욱,박오환,이은주,추혜정,김상효,이상협,엄재욱 대한영상의학회 2009 Korean Journal of Radiology Vol.10 No.5

        Objective: The aim of this study was to determine the efficacy of the use of an ultrasound-guided fine-needle aspiration biopsy (US-FNAB) to diagnose thyroid nodules smaller than 5 mm in the maximum diameter and to evaluate pathological findings of small thyroid malignancies. Materials and Methods: From May 2007 to April 2008, we evaluated the findings of US-FNABs of small thyroid nodules less than 5 mm in the maximum diameter. The cytopathological findings were retrospectively reviewed and the diagnostic performance of the use of an US-FNAB was examined in all patients. Results: Of 201 small thyroid nodules in 180 patients, there were 162 adequate specimens (81%). Among 180 patients, 75 patients underwent thyroid surgery and 50 malignant and 33 benign nodules were identified based on a pathological examination. All small malignant thyroid nodules were identified as papillary thyroid microcarcinomas (PTMCs). There were 34 (55%) true positive, 0 (0%) false positive, 23 (37%) true negative and five (8%) false negative results for malignancy after performing a first US-FNAB in 62 surgically confirmed nodules. The sensitivity (87%), specificity (100%), positive predictive value (100%), negative predictive value (82%), accuracy (92%), false positive rate (0%) and false negative rate (8%) for an US-FNAB were determined. In 23 patients with a primary PTMC, capsular invasion (9%, 2 of 23), a perithyroidal lymph node metastasis (30%, 7 of 23), the rate of multifocality (9%, 2 of 23) and bilaterality (4%, 1 of 23) were also determined. Conclusion: An US-FNAB of thyroid nodules smaller than 5 mm in the maximum diameter is an effective diagnostic procedure. Objective: The aim of this study was to determine the efficacy of the use of an ultrasound-guided fine-needle aspiration biopsy (US-FNAB) to diagnose thyroid nodules smaller than 5 mm in the maximum diameter and to evaluate pathological findings of small thyroid malignancies. Materials and Methods: From May 2007 to April 2008, we evaluated the findings of US-FNABs of small thyroid nodules less than 5 mm in the maximum diameter. The cytopathological findings were retrospectively reviewed and the diagnostic performance of the use of an US-FNAB was examined in all patients. Results: Of 201 small thyroid nodules in 180 patients, there were 162 adequate specimens (81%). Among 180 patients, 75 patients underwent thyroid surgery and 50 malignant and 33 benign nodules were identified based on a pathological examination. All small malignant thyroid nodules were identified as papillary thyroid microcarcinomas (PTMCs). There were 34 (55%) true positive, 0 (0%) false positive, 23 (37%) true negative and five (8%) false negative results for malignancy after performing a first US-FNAB in 62 surgically confirmed nodules. The sensitivity (87%), specificity (100%), positive predictive value (100%), negative predictive value (82%), accuracy (92%), false positive rate (0%) and false negative rate (8%) for an US-FNAB were determined. In 23 patients with a primary PTMC, capsular invasion (9%, 2 of 23), a perithyroidal lymph node metastasis (30%, 7 of 23), the rate of multifocality (9%, 2 of 23) and bilaterality (4%, 1 of 23) were also determined. Conclusion: An US-FNAB of thyroid nodules smaller than 5 mm in the maximum diameter is an effective diagnostic procedure.

      • KCI등재
      • KCI등재

        Correlations between the Various Methods of Estimating Prostate Volume: Transabdominal, Transrectal, and Three-Dimensional US

        Sun Ho Kim,김승협 대한영상의학회 2008 Korean Journal of Radiology Vol.9 No.2

        Objective: To evaluate the correlations between prostate volumes estimated by transabdominal, transrectal, and three-dimensional US and the factors affecting the differences. Materials and Methods: The prostate volumes of 94 consecutive patients were measured by both transabdominal and transrectal US. Next, the prostate volumes of 58 other patients was measured by both transrectal and three-dimensional US. We evaluated the degree of correlation and mean difference in each comparison. We also analyzed possible factors affecting the differences, such as the experiences of examiners in transrectal US, bladder volume, and prostate volume. Results: In the comparison of transabdominal and transrectal US methods, the mean difference was 8.4 10.5 mL and correlation coefficient (r) was 0.775 (p < 0.01). The experienced examiner for the transrectal US method had the highest correlation (r = 0.967) and the significantly smallest difference (5.4 3.9 mL) compared to the other examiners (the beginner and the trained; p < 0.05). Prostate volume measured by transrectal US showed a weak correlation with the difference (r = 0.360, p < 0.05). Bladder volume did not show significant correlation with the difference (r = 0.043, p > 0.05). The comparison between the transrectal and three-dimensional US methods revealed a mean difference of 3.7 3.4 mL and the correlation coefficient was 0.924 for the experienced examiner. Furthermore, no significant difference existed between examiners (p > 0.05). Prostate volume measured by transrectal US showed a positive correlation with the difference for the beginner only (r = 0.405, p < 0.05). Conclusion: In the prostate volume estimation by US, experience in transrectal US is important in the correlation with transabdominal US, but not with threedimensional US. Also, less experienced examiners’ assessment of the prostate volume can be affected by prostate volume itself.

      • KCI등재

        Nonpalpable Breast Masses: Evaluation by US Elastography

        Cho, Nariya,Moon, Woo Kyung,Park, Jeong Seon,Cha, Joo Hee,Jang, Mijung,Seong, Min Hyun The Korean Radiological Society 2008 KOREAN JOURNAL OF RADIOLOGY Vol.9 No.2

        <P><B>Objective</B></P><P>To compare the diagnostic performances of conventional ultrasound (US) and US elastography for the differentiation of nonpalpable breast masses, and to evaluate whether elastography is helpful at reducing the number of benign biopsies, using histological analysis as a reference standard.</P><P><B>Materials and Methods</B></P><P>Conventional US and real-time elastographic images were obtained for 100 women who had been scheduled for a US-guided core biopsy of 100 nonpalpable breast masses (83 benign, 17 malignant). Two experienced radiologists unaware of the biopsy and clinical findings analyzed conventional US and elastographic images by consensus, and classified lesions based on degree of suspicion regarding the probability of malignancy. Results were evaluated by receiver operating characteristic curve analysis. In addition, the authors investigated whether a subset of lesions was categorized as suspicious by conventional US, but as benign by elastography.</P><P><B>Results</B></P><P>Areas under the ROC curves (Az values) were 0.901 for conventional US and 0.916 for elastography (<I>p</I> = 0.808). For BI-RADS category 4a lesions, 44% (22 of 50) had an elasticity score of 1 and all were found to be benign.</P><P><B>Conclusion</B></P><P>Elastography was found to have a diagnostic performance comparable to that of conventional US for the differentiation of nonpalpable breast masses. The authors conclude that BI-RADS category 4a lesions with an elasticity score of 1 probably do not require biopsy.</P>

      • KCI등재

        Nonpalpable Breast Masses: Evaluation by US Elastography

        조나리야,문우경,박정선,Joo Hee Cha,Mijung Jang,Min Hyun Seong 대한영상의학회 2008 Korean Journal of Radiology Vol.9 No.2

        Objective: To compare the diagnostic performances of conventional ultrasound (US) and US elastography for the differentiation of nonpalpable breast masses, and to evaluate whether elastography is helpful at reducing the number of benign biopsies, using histological analysis as a reference standard. Materials and Methods: Conventional US and real-time elastographic images were obtained for 100 women who had been scheduled for a US-guided core biopsy of 100 nonpalpable breast masses (83 benign, 17 malignant). Two experienced radiologists unaware of the biopsy and clinical findings analyzed conventional US and elastographic images by consensus, and classified lesions based on degree of suspicion regarding the probability of malignancy. Results were evaluated by receiver operating characteristic curve analysis. In addition, the authors investigated whether a subset of lesions was categorized as suspicious by conventional US, but as benign by elastography. Results: Areas under the ROC curves (Az values) were 0.901 for conventional US and 0.916 for elastography (p = 0.808). For BI-RADS category 4a lesions, 44% (22 of 50) had an elasticity score of 1 and all were found to be benign. Conclusion: Elastography was found to have a diagnostic performance comparable to that of conventional US for the differentiation of nonpalpable breast masses. The authors conclude that BI-RADS category 4a lesions with an elasticity score of 1 probably do not require biopsy.

      • KCI등재

        Usefulness of Ultrasound and Ultrasound-guided Fine-Needle Aspiration Biopsy for Axillary Staging in Breast Cancer: Analysis of 327 patients at a single institution

        장미정,김선미,류채연,문우경,조나리야,강은영,김성원,박소연,김지현,김유정 대한초음파의학회 2010 ULTRASONOGRAPHY Vol.29 No.4

        Purpose: To evaluate the accuracy of ultrasound (US) and US-guided fine needle aspiration biopsy (FNAB) for the diagnosis of metastasis in the axillary lymph node (LN) of patients with breast cancer. Materials and Methods: A retrospective review of the data was performed on 327breast cancer patients that underwent axillary US from Jun 2006 to July 2008. USguided FNAB was performed when a LN indicated suspicious findings. Results of FNAB were compared with those of subsequent surgery. Results: Of the 327 patients, 111 showed suspicious findings on US and underwent FNAB. Among the 111 cases, 73 (66%) were positive for cancer, while 38 (34%)were negative results. A Total of 254 patients who had normal findings on US (n=216) and negative results on FNAB (n=38) underwent SNB, of which 56 (22%)were proven to have metastasis. Sensitivity and specificity of US were 61.9% and 81.8%, respectively, with a positive predictive value (PPV) of 65.8% and negative predictive value (NPV) of 79.2%. Sensitivity and specificity of US-guided FNAB were 86.9% and 100%, respectively, with a PPV of 100% and a NPV of 71.7%. Conclusion: US and US-guided FNAB performed for axillary staging are useful methods with a high specificity and positive predictive value in invasive breast cancer patients.

      • KCI등재

        장경 1 cm 이하 갑상선 결절의 초음파 유도하 세침흡인생검

        김상수,인현신,은충기 대한초음파의학회 2010 ULTRASONOGRAPHY Vol.29 No.1

        Purpose: The aim of this study is to determine the efficacy of ultrasound-guided fine-needle aspiration biopsy (US-FNAB) of thyroid nodules that are equal to or less than 1 cm at the maximum diameter. Materials and Methods: The US-FNABs performed on thyroid nodules from March to August 2009 were included in this study. We retrospectively evaluated the cytopathologic results as well as any complications associated with the procedure. Results: Of the 241 thyroid nodules (range: 0.1 - 1.0 cm, mean size: 5.8 mm) in 184 patients (female: male = 164:20, mean age: 49.0 years, age range: 18 - 77 years old), the incidence of an inadequate sample was 14.1% (34/241) for the US-FNABs. Eighty six nodules were surgically removed in 62 patients, of which 15 were confirmed to be benign nodules and 71 were confirmed to be malignant nodules. The number of true positive, false positive, true negative and false negative results for US-FNAB were 59, 0, 10 and 3%, respectively, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 95.2%, 100%, 100%, 76.9% and 95.8%, respectively. All the false negative cases were less than 3 mm at the maximal diameter. There were no serious complications in all the patients. Conclusion: US-FNAB was effective for the cases of thyroid nodule under 1 cm at the maximal diameter. However, a false negative result of US-FNAB should be considered for the cases of very small nodules that are less than 3 mm at the maximal diameter. 목적: 장경 1 cm 이하인 갑상선 결절에 대한 초음파 유도하 세침흡인생검의 효율성을 알아 보고자 하였다. 대상 및 방법: 2009년 3월부터 8월까지 갑상선 결절의세침흡인생검을 받은 환자 중 결절의 장경이 1 cm 이하인결절을 대상으로 세포진단결과와 수술 후 확진된 병리결과를 비교 분석하고 세침흡인생검에 따른 합병증 발생을조사하였다. 결과: 총 184명의 환자에서 (여자 : 남자 = 164 : 20,평균 연령 : 49세, 범위 : 18-77세) 장경 1 cm 이하인 갑상선 결절 241개 중에서 (평균 : 0.58 cm, 범위 : 0.1 -1.0 cm) 첫 번째 세침흡인생검에서 불충분한 검체로 확인된 경우가 14.1% (34개) 였다. 62명의 환자가 수술을 받았고 86개의 결절이 조직학적으로 확진되었는데, 71개의결절은 갑상선 유두암이었고 15개는 양성이었다. 86개의결절에 대한 첫 번째 세침흡인생검은 진양성 59, 위양성0, 진음성 10, 위음성 3을 보였으며, 민감도 95.2%, 특이도 100%, 양성예측도 100%, 음성예측도 76.9% 및 정확성 95.8% 이었다. 3건의 위음성의 경우 모두 장경 3 mm 미만의 결절이었고 모든 환자에서 중대한 합병증은 관찰되지 않았다. 결론: 장경 1 cm 이하 갑상선 결절에 대한 세침흡인생검은 효율적이다. 하지만 장경이 3 mm 이하인 미세 갑상선유두암에 있어서는 위음성의 결과가 초래될 수도 있으므로 첫 번째 세침흡인생검에서 음성의 결과를 보이더라도추가적인 세침흡인생검을 시행하는 등의 주의가 필요하다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼