RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Ultrasonic Degradation of Endocrine Disrupting Compounds in Seawater and Brackish Water

        So Young Park,Jong Sung Park,Ha Yoon Lee,Ji Yong Heo,Yeo Min Yoon,Kyung Ho Choi,Nam Guk Her 대한환경공학회 2011 Environmental Engineering Research Vol.16 No.3

        In this study, a series of experiments was conducted on the relative degradation of commonly known endocrine-disrupting compounds such as bisphenol A (BPA) and 17α-ethinyl estradiol (Ee₂) in a single-component aqueous solution using 28 and 580 kHz ultrasonic reactors. The experiments were conducted with three different types of model water: deionized water (DI), synthetic brackish water (SBW), and synthetic seawater (SSW) at pH 4, 7.5, and 11 in the presence of inert glass beads and humic acids. Significantly higher sonochemical degradation (93-97% for BPA) occurred at 580 kHz than at 28 kHz (43-61% for BPA), regardless of water type. A slightly higher degradation was observed for Ee₂ compared to that of BPA. The degradation rate of BPA and Ee₂ in DI water, SBW, and SSW after 30 min of ultrasound irradiation at 580 kHz increased slightly with the increase in pH from 4 (0.073-0.091 min-1 for BPA and 0.081-0.094 min-1 for Ee₂) to 7.5 (0.087-0.114 min-1 for BPA and 0.092?0.124 min-1 for Ee₂). In contrast, significant degradation was observed at pH 11 (0.149-0.221 min-1 for BPA and 0.147-0.228 min-1 for Ee₂). For the given frequencies of 28 and 580 kHz, the degradation rate increased in the presence of glass beads (0.1 mm and 25 g) for both BPA and Ee₂: 0.018-0.107 min-1 without beads and 0.052-0.142 min-1 with beads for BPA; 0.021-0.111 min-1 without beads and 0.054-0.136 min-1 with beads for Ee₂. A slight increase in degradation of both BPA and Ee₂ was found as the concentration of dissolved organic carbon (DOC, humic acids) increased in both SBW and SSW: 0.107-0.115 min-1 in SBW and 0.087-0.101 min-1 in SSW for BPA; 0.111-0.111 min-1 in SWB and 0.092-0.105 min-1 in SSW for Ee₂. After 30 min of sonicating the humic acid solution, DOC removal varied depending on the water type: 27% (3 mg L-1) and 7% (10 mg L-1) in SBW and 7% (3 mg L-1) and 4% (10 mg L-1) in SSW.

      • KCI등재

        Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

        Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

        Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

      • 18–30세 사이에 발생하는 뇌경색의 특징, 다기관 레지스트리 연구

        장윤경,송태진,김용재,허지회,이경열,김영은,장민욱,조수진,강석윤 이화여자대학교 의과학연구소 2017 EMJ (Ewha medical journal) Vol.40 No.3

        Objectives: Although there have been several reports that described characteristics for young age stroke, information regarding very young age (18–30 years old) has been limited. We aimed to analyze demographic factors, stroke subtype, and 3-month outcome in acute ischemic stroke patient who have relatively very young age in multicenter stroke registry. Methods: We evaluated all 122 (7.1%) consecutive acute ischemic stroke (within 7 days after symptom onset) patients aged 18 to 30 from 17,144 patients who registered in multicenter prospective stroke registry, 1997 to 2012. Etiology was classified by Trial of Org 10172 in Acute Stroke Treatment criteria. Stroke severity was defined as National Institutes of Health Stroke Scale (NIHSS) and stroke outcome was defined by modified Rankin scale (mRS) at 3 months after index stroke. Results: The mean age of all included patients was 25.1±3.7 years and 76 patients (62.2%) were male. The median NIHSS at admission was 4. Considering stroke subtype, 37 patients (30.3%) had stroke of other determined etiology (SOD), 37 (30.3%) had undetermined negative evaluation (UN) and 31 (25.4%) had cardioembolism (CE) were frequently noted. After adjusting age, sex and variables which had P<0.1 in univariable analysis (NIHSS and stroke subtype), CE stroke subtype (odds ratio, 4.68; 95% confidence interval, 1.42–15.48; P=0.011) were significantly associated with poor functional outcome (mRS≥3). Conclusion: In very young age ischemic stroke patients, SOD and UN stroke subtype were most common and CE stroke subtype was independently associated with poor discharge outcome.

      • Comparisons of obstetrical outcomes among vaginal, intramuscular progesterone treatment and conservative management for the prevention of preterm birth in twin pregnancies with a short cervix

        ( Young Li Kim ),( Young Jae Lee ),( Hee Young Cho ),( Eun Ah Kim ),( Min Jung Baek ),( Young Ran Kim ),( Sukho Kang ),( Ji Yeon Lee ) 대한산부인과학회 2016 대한산부인과학회 학술대회 Vol.102 No.-

        목적: To determine the differences in pregnancy outcomes among cases treated by vaginal progesterone, intramuscular(IM) progesterone and conservative management in twin pregnancies with a short cervix. 방법: This is a retrospective study of 273 twin pregnancies complicated by a short cervix(<2.5cm) who delivered from 2007 to 2016 in CHA Bundang Medical Center. Women who received cervical cerclage were excluded. Treatment groups included 1) group I; conservative management group without progesterone treatment(n=174), 2) group II; vaginal progesterone suppository group(n=30), 3) group III; IM progesterone injection group(n=69). Primary outcomes were spontaneous birth at <28, 32, 34, or 36 weeks of gestational age(GA). The secondary outcomes included hospitalized for tocolytics or antenatal corticosteroids, small for gestational age and low APGAR score(<7) at 5 min. 결과: Preterm birth before 36 weeks of GA was different among 3 groups(29.3%[51/174] vs.20.0%[6/30] vs.43.5%[30/69], p=0.034). Low APGAR score(<7) at 5min was significantly different among 3 groups(7.8%[27/348] vs.5.0%[3/60] vs.15.2%[21/138], p=0.018). After multivariate analysis, preterm birth(<36 weeks) occurred more frequently in group III than group I(aOR 6.90 95%CI:1.06-45.04, p=0.044). However, there was no significant difference between group II and III. Meanwhile, there were more cases with low APGAR score(<7) at 5 min in group III than group I(aOR 6.58 95%CI:1.43-30.21, p=0.015) and group II(aOR 17.04 95%CI:1.56-185.74, p=0.020) after multivariate analysis. 결론: In twin pregnancies complicated by short cervical length, IM progesterone group showed significantly greater occurrence of preterm birth before 36 weeks of GA in comparison with vaginal progesterone group and conservative management group.

      • 디지털 음악 및 아날로그 음악이 악력에 미치는 영향 평가

        최민지 ( Min Ji Choi ),홍지혜 ( Ji Hye Hong ),송영웅 ( Young Woong Song ) 대구가톨릭대학교 자연과학연구소 2011 자연과학연구논문집 Vol.9 No.1

        This study evaluated the effect of the music type (analog and digital) on the grip strength. Five male and five female healthy college students participated in the experiment. The independent variables were music type (analog, digital, no music) and listening time (5 min., 10 min., and 15 min.). The classic LP disc was used as the analog music and the LP was converted to mp3 to make the digital music source. Grip forces were measured every 5 minutes until 15 minutes using Jamar strain guqge. Mean forces and peak forces were used as dependent variables. The analysis of variance showed that there was no difference between analog and digital music (p>0.05). Only, the gender effect was statistically significant (p<0.05). These results should be verified using different types of music (not only classical music) or preferred music, during different listening time duration (>15 minutes).

      • Comparative evaluation of the algorithms for parametric mapping of the novel myocardial PET imaging agent <sup>18</sup> F-FPTP

        Kim, Ji Who,Seo, Seongho,Kim, Hyeon Sik,Kim, Dong-Yeon,Lee, Ho-Young,Kang, Keon Wook,Lee, Dong Soo,Bom, Hee-Seung,Min, Jung-Joon,Lee, Jae Sung Springer Japan 2017 Annals of nuclear medicine Vol.31 No.6

        <P><B>Objective</B></P><P>(<SUP>18</SUP>F-fluoropentyl)triphenylphosphonium salt (<SUP>18</SUP>F-FPTP) is a new promising myocardial PET imaging tracer. It shows high accumulation in cardiomyocytes and rapid clearance from liver. We performed compartmental analysis of <SUP>18</SUP>F-FPTP PET images in rat and evaluated two linear analyses: linear least-squares (LLS) and a basis function method (BFM) for generating parametric images. The minimum dynamic scan duration for kinetic analysis was also investigated and computer simulation undertaken.</P><P><B>Methods</B></P><P><SUP>18</SUP>F-FPTP dynamic PET (18 min) and CT images were acquired from rats with myocardial infarction (MI) (<I>n</I> = 12). Regions of interest (ROIs) were on the left ventricle, normal myocardium, and MI region. Two-compartment (<I>K</I><SUB>1</SUB> and <I>k</I><SUB>2</SUB>; 2C2P) and three-compartment (<I>K</I><SUB>1</SUB>–<I>k</I><SUB>3</SUB>; 3C3P) models with irreversible uptake were compared for goodness-of-fit. Partial volume and spillover correction terms (<I>V</I><SUB><I>a</I></SUB> and <I>α</I> = 1 − <I>V</I><SUB><I>a</I></SUB>) were also incorporated. LLS and BFM were applied to ROI- and voxel-based kinetic parameter estimations. Results were compared with the standard ROI-based nonlinear least-squares (NLS) results of the corresponding compartment model. A simulation explored statistical properties of the estimation methods.</P><P><B>Results</B></P><P>The 2C2P model was most suitable for describing <SUP>18</SUP>F-FPTP kinetics. Average <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, and <I>V</I><SUB><I>a</I></SUB> values were, respectively, 6.8 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.44 in normal myocardium and 1.4 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.32, in MI tissue. Ten minutes of data was sufficient for the estimation. LLS and BFM estimations correlated well with NLS values for the ROI level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.06<I>x</I> + 0.13, <I>r</I><SUP><I>2</I></SUP> = 0.96 and <I>y</I> = 1.13<I>x</I> + 0.08, <I>r</I><SUP><I>2</I></SUP> = 0.97) and voxel level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.22<I>x</I> − 0.30, <I>r</I><SUP><I>2</I></SUP> = 0.90 and <I>y</I> = 1.26<I>x</I> + 0.00, <I>r</I><SUP><I>2</I></SUP> = 0.92). Regional distribution of kinetic parametric images (<I>αK</I><SUB>1</SUB>, <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, <I>V</I><SUB>a</SUB>) was physiologically relevant. LLS and BFM showed more robust characteristics than NLS in the simulation.</P><P><B>Conclusions</B></P><P>Fast kinetics and highly specific uptake of <SUP>18</SUP>F-FPTP by myocardium enabled quantitative analysis with the 2C2P model using only the initial 10 min of data. LLS and BFM were feasible for estimating voxel-wise parameters. These two methods will be useful for quantitative evaluation of <SUP>18</SUP>F-FPTP distribution in myocardium and in further studies with different conditions, disease models, and species.</P><P><B>Electronic supplementary material</B></P><P>The online version of this article (doi:10.1007/s12149-017-1171-6) contains supplementary material, which is available to authorized users.</P>

      • KCI등재

        열처리에 의한 Morganella morganii와 Photobacterium phosphoreum 유래 Histidine Decarboxylase의 불활성화

        박원민(Won-Min Pak),김꽃봉우리(Koth-Bong-Woo-Ri Kim),김민지(Min-Ji Kim),박지혜(Ji-Hye Park),배난영(Nan-Young Bae),박선희(Sun-Hee Park),안동현(Dong-Hyun Ahn) 한국식품영양과학회 2016 한국식품영양과학회지 Vol.45 No.3

        Histamine을 생성하는 Morganella morganii와 Photobacterium phosphoreum으로부터 crude histidine decarboxylase(HDC)를 추출하여 65~121°C로 열처리한 다음 균의 생육 및 효소 활성 변화에 대해 살펴보았다. 그 결과 M. morganii와 P. phosphoreum은 모든 열처리 조건에서 비 가열 처리구와 비교 시 균의 생육이 저해됨을 확인하였다. M. morganii와 P. phosphoreum 유래 HDC의 효소 활성은 65°C에서 90% 이상의 효소 활성이 저해됨을 확인하였고, 온도가 증가함에 따라 유의적으로 활성이 억제되는 것으로 나타났다. SDS-PAGE 결과에서는 65~100°C 범위에서 비가열 처리구와 비교 시 조효소액의 단백질 패턴의 변화가 크지 않았으나, 121°C에서 단백질 band의 강도가 크게 약해졌다. Native-PAGE에서는 65°C 처리 조건에서부터 단백질 패턴의 변화가 크게 나타났다. 따라서 가열처리(65~121°C)는 histamine 생성균인 M. morganii와 P. phosphoreum의 생육을 억제할 뿐만 아니라 HDC의 효소 활성도가 저해됨을 확인하여, 식품산업에서 적용되고 있는 열처리 조건에서 histamine 생성 억제에 큰 효과가 있는 것으로 생각한다. This study was performed to investigate the effects of various thermal treatments on the growth of Morganella morganii and Photobacterium phosphoreum and activity of crude histidine decarboxylase (HDC) obtained from M. morganii and P. phosphoreum. Crude HDC and the two strains were treated at 65°C/30 min, 80°C/10 min, 100°C/10 min, and 121°C/10 min. Activity of crude HDC decreased with increasing temperature. Viable cells counts of M. morganii and P. phosphoreum were not detected in any heated samples. SDS-PAGE patterns of heated HDC did not show significant differences up to 100°C. However, at 121°C, protein band intensity was weakened. In native-PAGE, there was a major change in the pattern of HDC at 65°C. These results suggest that thermal treatment can help to reduce histamine production by reducing HDC activity and growth of M. morganii and P. phosphoreum.

      • 젊은 성인에서 흡연에 의한 상완동맥 내피기능의 부전에 관한 연구

        이상철,권영주,방덕원,이선해,이보영,김지욱,김영훈,온영근,현민수,김성구 순천향의학연구소 2002 Journal of Soonchunhyang Medical Science Vol.8 No.1

        Background and Objectives : Cigarette smoking is a major factor and the most modifiable risk factor for atherosclerosis. Endothelial dysfunction is an early event in atherosclerosis, before the structural change of the systemic arteries. We hypothesized that endothelial dysfunction might be present in the systemic arteries of young adult smokers and that this might be dose-dependent phenomenon. Therefore, we try to certify that smoking is associated with endothelial dysfunction in healthy young adults without other risk factor of atherosclerosis. Subjects and Methods : we studied noninvasively 29 subjects aged 3 to 4 decades without other risk factor of atherosclerosis, they were composed of the two groups, current smokers(n=15) and nonsmokers(n=14). Smoking history varied from 3 to 20 pack years. Using high-resolution ultrasound, vessel diameter and mean flow rate were measured at rest, during reactive hyperemia(with flow-mediated endothelium-dependent dilation), and after sublingual nitroglycerin(NG-induced endothelium-independent vasodilation). Result : Flow mediated endothelium dependent dilation was observed in the control subjects (9.4±3.44%) but was impaired in the smokers(5.8±2.51%)(p=0.004). NG-induced endothelium independent dilation is no difference in all subjects. Conclusion : Cigarette smoking is associated with endothelial dysfunction in healthy young adults.

      • KCI등재

        플라즈마 및 직접 기상 불소화에 따른 활성탄소섬유의 초산가스 흡착 특성

        이란은 ( Raneun Lee ),임채훈 ( Chaehun Lim ),김민지 ( Min-ji Kim ),이영석 ( Young-seak Lee ) 한국공업화학회 2021 공업화학 Vol.32 No.1

        실내 환경 오염물질인 휘발성 유기화합물(volatile organic compounds)인 초산에 대한 핏치계 활성탄소섬유의 흡착 성능을 향상시키기 위해 불소화를 진행하였다. 불소화에는 플라즈마 불소화와 직접 기상 불소화법을 사용하였으며, 두 가지 방식으로 불소화한 활성탄소섬유의 초산가스 흡착 성능을 고찰하였다. 불소가 도입된 활성탄소섬유의 표면 특성을 알아보기 위하여 X선 광전자 분광법(XPS)을 분석하였고 그 기공특성은 77K 질소 흡착법을 통하여 분석하였다. 초산가스의 흡착 성능은 가스 크로마토그래피를 통하여 측정하였으며, 플라즈마 불소화 된 활성탄소섬유의 파과시간이 790 min으로 650 min인 미처리 활성탄소섬유에 비해 파과시간이 지연되었음을 확인할 수 있으나, 직접 기상 불소화 표면처리한 활성탄소섬유의 파과시간은 390 min으로 오히려 흡착성능이 저해되었다. 이는 플라즈마 불소화 된 활성탄소섬유는 그 비표면적의 변화 없이, 표면에 도입된 불소 관능기가 초산가스(CH<sub>3</sub>COOH)와 정전기적 인력으로 흡착성능이 증가하였다. 반면, 직접 기상 불소화 된 활성탄소섬유는 그 비표면적이 55%까지 크게 감소하여 초산가스에 대한 물리적 흡착 효과가 현저히 감소하였다. Fluorination was carried out to improve the adsorption performance of pitch-based activated carbon fibers (ACFs) onto acetic acid. Both plasma and direct gas fluorination were used for fluorination, and the acetic acid gas adsorption performance of fluorinated ACFs was investigated. X-ray photoelectron spectroscopy (XPS) is analyzed to determine the surface characteristics of ACFs, and the pore characteristics were analyzed by 77 K nitrogen adsorption. An adsorption performance was measured through gas chromatography, and it was confirmed that the breakthrough time of plasma fluorinated sample was 790 min and that the breakthrough time was delayed compared to that of using untreated one of 650 min. However, the breakthrough time of direct gas fluorinated sample was 390 min, indicating that the adsorption performance was inhibited. The plasma fluorinated ACFs showed an increase in the adsorption performance due to an electrostatic attraction between the acetic acid gas (CH<sub>3</sub>COOH) with the fluorine group introduced to the surface without changing its specific surface area. On the other hand, the specific surface area of the direct gas fluorinated ACFs decreased significantly up to 55%, and the physical adsorption effect on the acetic acid gas also reduced.

      • KCI등재

        물리ㆍ화학적 처리에 의한 멸균 초콜릿 우유 오염균의 생육억제 효과

        최문경(Moon-Kyoung Choi),윤소영(So-Young Yoon),이소영(So-Young Lee),김꽃봉우리(Koth-Bong-Woo-Ri Kim),이청조(Chung-Jo Lee),정지연(Ji-Yeon Jung),곽지희(Ji-Hee Kwak),김민지(Min-Ji Kim),김동현(Dong-Hyun Kim),선우찬(Chan Sunwoo),이주운(Ju-W 한국식품영양과학회 2011 한국식품영양과학회지 Vol.40 No.8

        멸균 초콜릿 우유로부터 분리한 내열성 균주에 대해 열, pH, 전해수, 오존처리, microwave 및 감마선 처리를 하여 균주의 사멸효과에 대해 알아보았다. 균주의 지방산 분석과 API kit를 통하여 균주를 동정한 결과, Bacillus lentus로 동정되었으며, 잠정적으로 Bacillus lentus M1으로 명명하였다. B. lentus M1에 110℃, 15분간 열처리하였을 경우 생육이 억제되었으며, pH 처리 시 pH 5 이하, 10 이상에서 생육이 억제된 것으로 나타났다. B. lentus M1에 대한 전해수의 항균활성을 paper disc법으로 측정한 결과, 높은 생육억제를 보였으며, 오존 처리의 경우 초기 균수가 10² CFU가량의 균을 10분 동안, 10³ CFU가량의 균을 30분 동안 처리 시 균의 생육이 억제되는 것으로 나타났다. Microwave를 1분간 처리 시 B. lentus M1이 모두 사멸한 것으로 나타났다. 감마선 조사의 경우, 1 kGy 조사 시 생균수가 1.61×10³ CFU로 초기 균수에 비해 4 log cycle 가량 균수가 감소하였으며 7 kGy에서 완전히 사멸하였다. 이상의 결과를 통해 열, pH, 전해수, 오존 처리 및 방사선 처리 방법이 멸균 초콜릿 우유의 생존 오염균인 B. lentus M1을 효과적으로 사멸시킬 수 있을 것으로 사료된다. This study was conducted to investigate the cause of microbiological contaminants in aseptic chocolate milk and evaluate the effect of a physicochemical treatment on the growth inhibition of isolated bacterial strains. The bacterium isolated from aseptic chocolate milk was identified as Bacillus lentus and was named B. lentus M1. In the heat and pH treatment, the growth of B. lentus was inhibited at 110℃ for >15 min and at pH’s <5 and >10. An electrolyzed water treatment against B. lentus M1, revealed 5 ㎜ growth past the inhibition zone. The effect of ozone gas on B. lentus M1 growth was evaluated using viable cell counts. When the initial number of B. lentus M1 was 10² and 10³ CFU, the bacteria were completely suppressed by ozone gas treatment for 10 and 30 min, respectively. In a microwave treatment, B. lentus M1 was sterilized following microwave treatment for 1 min. As the result of γ-irradiation against B. lentus M1, numbers decreased as the γ-irradiation dosage increased. These results show the growth inhibition effects against contaminants in aseptic chocolate milk using physicochemical treatments.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼