RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재
      • KCI등재

        Infusiblization of Iodine Doped Polycarbosilane for Silicon Carbide Fiber Fabrication

        서정민,허서에르딘키싱바야르,조광연,Seo, Jung-Min,Khishigbayar, Khos-Erdene,Cho, Kwang-Youn The Korean Fiber Society 2016 한국섬유공학회지 Vol.53 No.6

        Low molecular polycarbosilane (PCS) is used as raw material in the fabrication of continuous silicon carbide (SiC) fiber at a relatively low temperature using a low pressure stabilization method with iodine vapor. The low stabilization temperature provides a good environment to use the low molecular PCS for the melt-spun process, which has good spinnability, but also has many difficulties with the conventional oxidation curing method due to the low softening point of PCS. However, SiC fibers fabricated from the low molecular PCS have shown poor mechanical properties. In this study, we are aiming to improve those mechanical properties and fabricate high strength SiC fibers from low molecular PCS using the low pressure stabilization method. The ceramic yield of iodine doped PCS was increased in proportion to the iodine content after stabilization according to thermogravimetric analysis, and exhibits more than twice the tensile strength than fibers fabricated from as-received PCS.

      • KCI등재후보

        소아의 한약복용에 관한 임상적 실태 조사

        서정민,이상곤,황순이,김상찬,왕향란,조성언,백정한,Seo, Jung-Min,Lee, Sang-Gon,Hwang, Sun-Yi,Kim, Sang-Chan,Wang, Hyang-Ran,Jo, Sung-Eon,Baek, Jung-Han 대한한방소아과학회 2006 대한한방소아과학회지 Vol.20 No.3

        Objectives : Oriental medicine has set the no herb medicamentous dose for child, on the other hand the western medicine has it standardizing of age, weight or dimension of body. Therefore, we aimed to research the herb medicamentous dose for child being in being used in clinic. Methods : We made up a question of the oriental medical doctors of the master's and doctor's course in ○○ university. Results : 1. Child dose of herb medicine a time likes this. 1 pack is written prescription most at children patients under 1 year. 1 pack and 2 packs are written prescription most at children patients over 1 under 2. 2 packs are written prescription most at children patients over 2 under 3. 4 packs are written prescription most at children patients over 3 under 4. 10 packs are written prescription most at children patients over 8 under 14. Dose of herb medicine written prescription at children patients over 5 under 8 is in decentralization from 2 to 10 packs. 2. 2 or 3 times are most in a number of taking medicine a day. 3. 3 days are common in period of taking medicine under 5, over 10 days are common over 5. 4. It is necessary to regulating child dose of herb medicine.

      • KCI등재

        500W급 발전용 초소형 가스터빈 설계

        서정민,최범석,박준영,박철훈,김유일,Seo, Jeong-Min,Choi, Bum-Seok,Park, Jun-Young,Park, Cheol-Hoon,Kim, You-Il 한국군사과학기술학회 2011 한국군사과학기술학회지 Vol.14 No.6

        Design of 500W class UMGT(Ultra Micro Gas Turbine) for power generation is conducted. Basic design parameters are obtained by cycle analysis. Off-design performances are predicted by 1D aerodynamic design and 1D performance analysis of compressor and turbine. 3D impellers are designed and 3D performance analysis is carried out to predict the performance characteristics of UMGT. 1D and 3D performance analysis show similar results. Structure analysis is conducted to select materials. Titanium Alloy is proposed for structural stability.

      • 인문학의 위기, 어떻게 극복할 것인가

        서정민,Seo, Jeong-Min 한국대학교육협의회 2007 大學敎育 Vol.145 No.-

        현재의 상황을 인문학의 위기라고 전제한다면 상황을 극복하기 위한 고민이 반드시 뒤따라야 한다. 무엇보다도 '위기론'의 장본인인 인문학자들의 '자기반성'이 있어야하며 정부의 인문학 육성책에 대해서도 세밀한 검토와 지적이 필요하다. 아울러 정부와는 별도의 대학 차원, 작게는 학과나 단체 차원에서의 노력도 필요하다. 학문에 대한 자부심이 지나쳐 쓸데없는 우월의식을 갖는 것을 지양해야 하며, 과거를 돌아보는 반성의 자세로 전문성과 함께 대중성을 갖추기 위해 노력해야 한다. 위기를 기회로, 기회를 위기로 여기는 신중한 자세를 견지해야 한다.

      • 특집:에너지플랜트 및 핵심기자재 기술 - 플랜트용 가스터빈 기술

        서정민,박준영,최범석,Seo, Jeong-Min,Park, Jun-Yeong,Choe, Beom-Seok 재료연구소 2012 機械와 材料 Vol.24 No.1

        국내 플랜트산업의 낮은 외화가득률의 원인인 낮은 국산화율의 플랜트 기자재 중 하나인 가스터빈은 선진국대비 기술격차가 크고 해외의존도가 높다. 가스터빈은 플랜트 산업에 활용도가 높은 기자재며 특히 오일&가스 플랜트의 경우 upstream에서 downstream에 이르기까지 활용도가 매우 높다. 가스터빈 시장은 연 7.5%의 성장을 보이고 있으며 2015년에는 560억불에 달할 것으로 예상된다. 선진국에서는 ATS, NGST, ETN 등 범국가 단위로 가스터빈 기술을 개발해 왔으며, 최근에는 고효율, 저비용, 친환경 가스터빈 기술향상에 집중하고 있다. 가스터빈 기술은 이제 발전기를 지나 성숙기에 이르고 있지만 국내의 가스터빈 기술은 단위 부품 제작이나 면허 생산 등의 생산 기술에 치우친 초보적인 수준에 머물고 있다.

      • 예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석

        서정민,이창열,허현도,김완선,Seo, jung min,Lee, chang yeol,Huh, hyun do,Kim, wan sun 대한방사선치료학회 2015 대한방사선치료학회지 Vol.27 No.2

        Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatm 목 적 : 사이버나이프 종양 추적 시스템(Cyber-knife tumor tracking system)은 환자 외부에 부착한 LED marker에서 얻어진 실시간 호흡 주기 신호와 호흡에 따라 움직이는 종양의 위치와의 상관관계를 바탕으로 종양의 위치를 미리 예측하고 종양의 움직임을 치료기와 동기화 (Synchronize) 시켜 실시간으로 종양을 추적하며 치료하는 시스템이다. 본 연구의 목적은 사이버나이프 종양 추적 방사선 치료 중 기침이나 수면 등으로 인해 예측 불가능한 갑작스러운 호흡 형태 변화에 따른 종양 추적 방사선 치료 시스템의 정확도를 평가하고자 한다. 대상 및 방법 : 연구에 사용된 호흡 Log 파일은 본원에서 호흡 동조 방사선치료(Respiratory gating radiotherapy)나 사이버나이프 호흡 추적 방사선수술(Cyber-knife tracking radiosurgery)을 받았던 환자의 호흡 Log 파일을 바탕으로, 정현곡선 형태(Sinusoidal pattern)와 갑작스런 변화 형태(Sudden change pattern)의 Log 파일을 이용하여 측정이 가능하도록 재구성하였다. 재구성 된 호흡 Log 파일을 사이버나이프 동적 흉부 팬텀에 입력하여 호흡에 따른 움직임을 구현할 수 있도록 기존 동적 흉부 팬텀의 구동장치를 추가 제작하였고, 호흡의 형태를 팬텀에 적용 시킬 수 있는 프로그램을 개발하였다. 팬텀 내부 표적(Ball cube target)의 움직임은 호흡의 크기에 따라 상하(Superior-Inferior)방향으로 5 mm, 10 mm, 20 mm 3가지 크기의 변위로 구동하게 하였다. 팬텀 내부 표적에 EBT3 필름 2장을 교차 삽입하여 표적 움직임의 변화에 따라 사이버나이프 제조사에서 제공된 End-to-End(E2E) test를 호흡의 형태에 따라 각각 5회씩 실시하고 측정하였다. 종양 추적 시스템의 정확도는 삽입된 필름을 분석하여 표적 오차(Targeting error)로 나타내었고, 추가로 E2E test가 진행되는 동안 상관관계 오차(Correlation error)를 측정하여 분석하였다. 결 과 : 표적 오차는 정현곡선 호흡 형태일 경우 표적 움직임의 크기가 5 mm, 10 mm, 20 mm 에 따라 각각 평균 $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, $2.37{\pm}0.17mm$이고, 갑작스런 호흡 변화 형태일 경우 각각 평균 $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, $2.44{\pm}0.26mm$으로 분석되었다. 표적 추적에 있어 변위 벡터의 길이로 정의할 수 있는 상관관계 오차는 정현곡선 호흡 형태일 경우 표적 움직임의 크기가 5 mm, 10 mm, 20 mm 에 따라 각각 평균 $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, $1.63{\pm}0.10mm$이고, 갑작스런 호흡 변화 형태일 경우 각각 평균 $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, $1.98{\pm}0.10mm$으로 분석되었다. 두 호흡 형태에서 모두 상관관계 오차 값이 클수록 표적 오차 값이 크게 나타났다. 정현곡선 호흡 형태의 표적 움직임 크기가 20 mm 이상일 경우, 두 오차 값 모두 사이버나이프 제조사의 권고치인 1.5 mm 이상으로 측정되었다. 결 론 : 표적 움직임의 크기가 클수록 표적 오차 값과 상관관계 오차 값이 증가하는 경향이 있었으며, 정현곡선 호흡 형태보다 갑작스런 호흡 변화 형태에서 오차 값이 크게 나타났다. 호흡의 형태가 규칙적인 정현 곡선 형태더라도 표적의 움직임이 클수록 종양 추적 시스템의 정확도가 감소하는 것으로 판단할 수 있다. 사이버나이프 종양 추적 시스템의 알고리즘을 이용하여 치료 시행 시 환자의 기침 등으로 인하여 갑작스럽게 예측 불가능한 호흡 변화가 있는 경우 치료를 멈추고 내부 표적 확인 과정을 재실시 하여야 하며 호

      • 신생아의 항문직장내압검사

        서정민,최윤미,이은희,전용훈,안승익,홍기천,신석환,Seo, Jeong-Meen,Choi, Yun-Mee,Lee, Eun-Hee,Jun, Yong-Hoon,Ahn, Seung-Ik,Hong, Kee-Chun,Shin, Seok-Hwan 대한소아외과학회 1999 소아외과 Vol.5 No.2

        To estimate the normal anal canal pressure in neonates, anal manometry was performed in 46 normal babies less than 6 days of age. Twenty-eight of the subjects were boys and 18 girls. All the subjects passed meconium within 24 hours after birth. Birth weights were above 2.4 kg. There were no sexual differences in birth weight, birth height, gestational age, postnatal age, or Apgar score (p<0.05). The mean manometry values were; anal sphincter length $18.6{\pm}3.9$ mm, high pressure zone (HPZ) $9.2{\pm}3.6$ mm, vector volume $2027.2{\pm}2440.7$ mmHg2cm, maximum pressure $42.3{\pm}17.4$ mmHg, and position of the maximum pressure $6.0{\pm}22.4$ mm. Only the HPZ of boys was longer than those of girls (p=0.005). In squeezing state, HPZ and the position of maximun pressure were not changed from resting state. HPZ, vector volume, and maximum pressure in boys were higher than those in girls. As the birth weight increased, the anal sphincter length (p=0.001) and the HPZ increased (p=0.047). The resting pressures of the anal canal were evaluated in three portions; /23 upper portion, $12.8{\pm}8.6$ mmHg, middle portion, $20.3{\pm}10.8$ mmHg, and lower portion, $26.1{\pm}12.9$ mmHg. These normal values may serve as guidelines for the evaluation, diagnosis and treatment of neonatal anal diseases.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼