RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        흡수성 고정판이 가토의 악골골절 치유에 미치는 영향

        박현욱,류동목,이한주,허원실,Park, Hyun-Wook,Ryu, Dong-Mok,Lee, Han-Joo,Huh, Won-Shil 대한악안면성형재건외과학회 1999 Maxillofacial Plastic Reconstructive Surgery Vol.21 No.2

        The purpose of this study is to evaluate the effects of resorbable plate in the healing process of mandibular fracture. Reduction and rigid fixation was carried out on the artificial mandibular fracture site of the rabbits, using a resorbable screw, 1.5mm in diameter and 4.0mm in length, and an absorbable plate 1.5mm in thickness(Lactosorb$^{(R)}$). En block tissue specimens with plate were taken from the rabbits at 4, 6, 8, and 10 weeks intervals and specimen were observed with light microscope under the hematoxylin-eosin staining, to observe the inflammatory reaction and tissue healing process. The following conclusions were drawn: 1. The subject displayed good healing with no signs of detachment of the fixation plate. 2. At 4 weeks, the plate was covered by the connective tissue. Then at 6 weeks, bone regeneration was discovered around the plate. 3. During the period of healing, no inflammatory reaction or foreign body reaction, as a result of using resorbable plate, were observed. 4. At 8 weeks, the initial phase of the absorption of the plate was observed. Then at 10 weeks, macrophage were observed around the plate, indicating the absorption phase was in process. From the above results, it can be determined that when the resorbable plate is applied to rabbit, full recuperation occurs naturally in the absence of inflammatory reaction and foreign body reaction. The selected study is clinically valuable in proving this procedure.

      • KCI등재

        흡수성 고정판이 가토의 악골골절 치유에 미치는 영향

        류동목(Dong Mok Ryu),박현욱(Hyun Wook Park),이한주(Han Joo Lee),허원실(Won Shil Huh) 대한악안면성형재건외과학회 1999 Maxillofacial Plastic Reconstructive Surgery Vol.21 No.2

        The purpose of this study is to evaluate the effects of resorbable plate in the healing process of mandibular fracture. Reduction and rigid fixation was carried out on the artificial mandibular fracture site of the rabbits, using a resorbable screw, 1.5mm in diameter and 4.0mm in length, and an absorbable plate 1.5mm in thickness (LactosorbR). En block tissue specimens with plate were taken from the rabbits at 4, 6, 8, and 10 weeks intervals and specimen were observed with light microscope under the hematoxylin-eosin staining, to observe the inflammatory reaction and tissue healing process. The following conclusions were drawn: 1. The subject displayed good healing with no signs of detachment of the fixation plate. 2. At 4 weeks, the plate was covered by the connective tissue. Then at 6 weeks, bone regeneration was discovered around the plate. 3. During the period of healing, no inflammatory reaction or foreign body reaction, as a result of using resorbable plate, were observed. 4. At 8 weeks, the initial phase of the absorption of the plate was observed. Then at 10 weeks, macrophage were observed around the plate, indicating the absorption phase was in process. From the above results, it can be determined that when the resorbable plate is applied to rabbit, full recuperation occurs naturally in the absence of inflammatory reaction and foreign body reaction. The selected study is clinically valuable in proving this procedure.

      • KCI등재

        구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구

        김일규,박승훈,장금수,양정은,장재원,사시카라 바라라만,Kim, Il-Kyu,Park, Seung-Hoon,Jang, Keum-Soo,Yang, Jung-Eun,Jang, Jae-Won,Sasikala, Balaraman 대한구강악안면외과학회 2009 대한구강악안면외과학회지 Vol.35 No.6

        Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

      • KCI등재

        컨테이너 검색기 이송대차 추진용 선형 유도전동기의 2차측 리액션플레이트 재질에 따른 특성 연구

        정재훈(Jae-Hoon Jeong),최장영(Jang-Young Choi),성소영(So-Young Sung),박종원(Jong-Won Park),임재원(Jaewon Lim) 대한전기학회 2016 전기학회논문지 Vol.65 No.1

        This paper presents the analysis of the analysis of thrust characteristics of linear induction motors(LIMs) according to secondary reaction plate. LIMs are well known as high speed transport systems, which can obtain thrust directly without gears and links, or auxiliary mechanisms. A simple structure, easy maintenance, and less environmental pollution are advantages of LIMs. In transport systems using LIMs, the secondary reaction plate is an important design factor, because it has considerable impact on the cost of the railway as well as the performance of the LIMs. This paper deals analyzed the characteristics of linear induction motor used for moving the vehicle of container scanner. Thrust, efficiency and load characteristic were interpreted with FEM regarding two models whose material of secondary reaction plate was copper and aluminum. It suggested the interpretation of thrust, efficiency and power factor characteristic along slip and compared the operation ability of linear induction motor through characteristics analysis along the load.

      • SCIESCOPUS

        Analysis of circular plates on two - parameter elastic foundation

        Saygun, Ahmet,Celik, Mecit Techno-Press 2003 Structural Engineering and Mechanics, An Int'l Jou Vol.15 No.2

        In this study, circular plates subjected to general type of loads and supported on a two-parameter elastic foundation are analysed. The stiffness, elastic bedding and soil shear effect matrices of a fully compatible ring sector plate element, developed by Saygun (1974), are obtained numerically assuming variable thickness of the element. Ring sector soil finite element is also defined to determine the deflection of the soil surface outside the domain of the plate in order to establish the interaction between the plate and the soil. According to Vallabhan and Das (1991) the elastic bedding (C) and shear parameters ($C_T$) of the foundation are expressed depending on the elastic constants ($E_s$, $V_s$) and the thickness of compressible soil layer ($H_s$) and they are calculated with a suitable iterative procedure. Using ring sector elements presented in this paper, permits the generalization of the loading and the boundary conditions of the soil outside the plate.

      • 석회판의 강도증가에 관한 연구

        이영석,이건직,박권필 順天大學校 1999 論文集 Vol.18 No.1

        This study focused on the increase of lime plate strength by adding reinforced material into limestone and chemical reaction with carbon dioxide gas. Also we did experiment to find the optimum content of plaster as a binding component. Carbon fiber as reinforced material has disadvantages. It did not mixed well in the forming process and had low cohesion force with limestone. Content of glass fiber showed optimum at 1.0cm, 4.16 wt% in lime plate. The increase of strength in lime plate was ??, after reaction with CO₂at 70℃ for 6hr. When lime plate consists of 40wt% of plaster, 4.16 wt% of 1.0cm glass fiber, its strength was ??

      • KCI등재

        Development of a Plate-Parallel Gridded Ionization Chamber with Gaseous Samples for Fusion Neutronics

        Y. S. Lee,김귀년,고인수,조무현,남궁원,Yu. M. Gledenov 한국물리학회 2008 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.53 No.4

        A plate-paralel gridded ionization chamber (PPGIC) with gaseous samples has been developed for measurement of the (n,α) reaction cross sections to evaluate radiation damage and nuclear heating in fusion and for the selection of fusion structural materials. The PPGIC was designed for its applications in an environment with an intense neutron source, like realistic fusion. However, the application of gaseous samples in the PPGIC essentialy lower the beam background and in comparison with a conventional GIC with a solid sample, the utilization of a gaseous sample has advantages of a very high geometrical efficiency and freedom from the eect of energy loss in sample. We have demonstrated the characteristics of the PPGIC and the possibilities of using the PPGIC with gaseous samples to measure the (n,α) reactions for fusion neutronics and nuclear data.

      • KCI등재

        지반반력계수(K30)와 변형률계수(Ev)에 대한 고찰

        김대상,최찬용,김성중,유진영,양신추 한국철도학회 2007 한국철도학회논문집 Vol.10 No.3

        Two modulus, strain modulus (Ev) and subgrade reaction modulus (K30) are being used as a standard for bearing stiffness in Korea Railroad design. The first is used in Europe and the other is used in Japan. The methodologies to obtain the two modulus are similar in using plate. But testing methods are different in loading to plate. Therefore, according to soil strain range, there should be large gap in not only computations of deformation modulus but also the necessary time to test. At first, this paper focuses on the two kinds of test methods to evaluate bearing stiffness. Secondly, based on elastic theory, the theory to obtain the two coefficients are studied thoroughly. Finally, the correlations between the two coefficients were analyzed and evaluated based on the field test results more than 38 places. The matching values for subgrade and ground between K30 and Ev2 are proposed with the consideration of the proposed strain reduction factor (1.5 for subgrade and 3 for ground) and safety factor, respectively.

      • KCI등재후보

        Effects of Nano-sized Diamond on Wettability and Interfacial Reaction for Immersion Sn Plating

        Yu, A-Mi,Kang, Nam-Hyun,Lee, Kang,Lee, Jong-Hyun The Korean Microelectronics and Packaging Society 2010 마이크로전자 및 패키징학회지 Vol.17 No.3

        Immersion Sn plating was produced on Cu foil by distributing nano-sized diamonds (ND). The ND distributed on the coating surface broke the continuity of Sn-oxide layer, therefore leading to penetrate the molten solder through the oxide and retarding the wettability degradation during a reflow process. Furthermore, the ND in the Sn coating played a role of diffusion barrier for Sn atoms and decreased the growth rate of intermetallic compound ($Cu_6Sn_5$) layer during the solid-state aging. The study confirmed the importance of ND to improve the wettability and reliability of the Sn plating. Complete dispersion of the ND within the immersion Sn plating needs to be further developed for the electronic packaging applications.

      • SCOPUSKCI등재

        반응소결 탄화규소의 접동조건에 따른 마찰계수 및 미세구조

        김호균,김인섭,이병하 한국세라믹학회 1995 한국세라믹학회지 Vol.32 No.7

        Reaction-bonded SiC-Si material was fabricated by infiltration of Si melt into a mixture of $\alpha$-SiC and carbon at 175$0^{\circ}C$ under the vacuum atmosphere. Wear properties were analyzed by ball-on-plate wear tester, changing loading weight, sliding speed, sliding time and atmosphere, Results showed that the friction coefficient was decreased with increasing load and sliding velocity. The lowest friction coefficient of 0.05 was obtained under an oil atmosphere. The analysis of the wear surface indicated that the areas wehre particles were pulled out and where free silicon particles worn out preferentially serve as liquid reservoirs to decrease the wear resistance.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼