RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
          펼치기
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Accuracy of cardiac output measurements during off-pump coronary artery bypass grafting: according to the vessel anastomosis sites

        Sung Yong Park,Dae Hee Kim,Han Bum Joe,Ji Young Yoo,Jin Soo Kim,Min Kang,Yong Woo Hong 대한마취통증의학회 2012 Korean Journal of Anesthesiology Vol.62 No.5

        Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB. Background: During beating heart surgery, the accuracy of cardiac output (CO) measurement techniques may be influenced by several factors. This study was conducted to analyze the clinical agreement among stat CO mode (SCO), continuous CO mode (CCO), arterial pressure waveform-based CO estimation (APCO), and transesophageal Doppler ultrasound technique (UCCO) according to the vessel anastomosis sites. Methods: This study was prospectively performed in 25 patients who would be undergoing elective OPCAB. Hemodynamic variables were recorded at the following time points: during left anterior descending (LAD) anastomosis at 1 min and 5 min; during obtuse marginal (OM) anastomosis at 1 min and 5 min: and during right coronary artery (RCA) anastomosis at 1 min and 5 min. The variables measured including the SCO, CCO, APCO, and UCCO. Results: CO measurement techniques showed different correlations according to vessel anastomosis site. However, the percent error observed was higher than the value of 30% postulated by the criteria of Critchley and Critchley during all study periods for all CO measurement techniques. Conclusions: In the beating heart procedure, SCO, CCO and APCO showed different correlations according to the vessel anastomosis sites and did not agree with UCCO. CO values from the various measurement techniques should be interpreted with caution during OPCAB.

      • SCIEKCI등재

        Reduction of Bacillus cereus Contamination in Biofilms on Stainless Steel Surfaces by Application of Sanitizers and Commercial Detergent

        Lee, Min-Jeong,Ha, Ji-Hyoung,Kim, Yong-Su,Ryu, Jee-Hoon,Ha, Sang-Do The Korean Society for Applied Biological Chemistr 2010 Applied Biological Chemistry (Appl Biol Chem) Vol.53 No.1

        We established the effectiveness of a washing, detergent and sanitizer treatments for reducing Bacillus cereus (B. cereus) contamination in biofilms on stainless steel surfaces. A water treatment did not affect biofilms and chlorine treatments at 200 ppm for 10 min and 300 ppm for 5 min, iodophor at 200 ppm for 10 min, and QAC at 400 ppm for 10 min were used to eliminate all B. cereus cells. B. cereus cells after detergent treatment were eliminated by chlorine at 100 ppm for 10 min, 200 ppm for 5 min, and 300 ppm for 3 min, and with iodophor at 100 ppm for 10 min and 200 ppm for 10 min, and QAC at 400 ppm for 10 min.

      • KCI등재

        Corrosion Behavior of Hastelloy C-276 for Carbon-anode-based Oxide Reduction Applications

        Jeon, Min Ku,Kim, Sung-Wook,Choi, Eun-Young Korean Radioactive Waste Society 2020 방사성폐기물학회지 Vol.18 No.3

        The corrosion behavior of Hastelloy C-276 was investigated to identify its applicability for carbon-anode-based oxide reduction (OR), in which Cl<sub>2</sub> and O<sub>2</sub> are simultaneously evolved at the anode. Under a 30 mL·min<sup>-1</sup> Cl<sub>2</sub> + 170 mL·min<sup>-1</sup> Ar flow, the corrosion rate was less than 1 g·m<sup>-2</sup>·h<sup>-1</sup> up to 500℃, whereas the rate increased exponentially from 500 to 700℃. The effects of the Cl<sub>2</sub>-O<sub>2</sub> composition on the corrosion rate at flow rates of 30 mL·min<sup>-1</sup> Cl<sub>2</sub>, 20 mL·min<sup>-1</sup> Cl<sub>2</sub> + 10 mL·min<sup>-1</sup> O<sub>2</sub>, and 10 mL·min<sup>-1</sup> Cl<sub>2</sub> + 20 mL·min<sup>-1</sup> O<sub>2</sub> with a constant 170 mL·min<sup>-1</sup> Ar flow rate at 600℃ was analyzed. Based on the data from an 8 h reaction, the fastest corrosion rate was observed for the 20 mL·min<sup>-1</sup> Cl<sub>2</sub> + 10 mL·min<sup>-1</sup> O<sub>2</sub> case, followed by 30 mL·min<sup>-1</sup> Cl<sub>2</sub> and 10 mL·min<sup>-1</sup> Cl<sub>2</sub> + 20 mL·min<sup>-1</sup> O<sub>2</sub>. The effects of the chlorine flow rate on the corrosion rate were negligible within the 5-30 mL·min<sup>-1</sup> range. A surface morphology analysis revealed the formation of vertical scratches in specimens that reacted under the Cl<sub>2</sub>-O<sub>2</sub> mixed gas condition.

      • KCI등재

        Corrosion Behavior of Inconel X-750 for Carbon Anode Oxide Reduction Application

        Jeon, Min Ku,Kim, Sung-Wook,Lee, Sang-Kwon,Choi, Eun-Young Korean Radioactive Waste Society 2020 방사성폐기물학회지 Vol.18 No.3

        The corrosion behavior of the Inconel X-750 alloy was investigated for its potential application under a Cl<sub>2</sub>-O<sub>2</sub> mixed gas flow in an Ar atmosphere. The corrosion rate was found to be negligible at temperatures up to 400℃ under a flow rate of 30 mL·min<sup>-1</sup> Cl<sub>2</sub> + 170 mL·min<sup>-1</sup> Ar, whereas an exponential increase was observed in the corrosion rate at temperatures greater than 500℃. The suppression of the corrosion reaction due to the presence of O<sub>2</sub> was verified experimentally at flow rates of 30 mL·min<sup>-1</sup> Cl<sub>2</sub> (4.96 g·m<sup>-2</sup>·h<sup>-1</sup>), 20 mL·min<sup>-1</sup> Cl<sub>2</sub> + 10 mL·min<sup>-1</sup> O<sub>2</sub> (2.02 g·m<sup>-2</sup> ·h<sup>-1</sup>), and 10 mL·min<sup>-1</sup> Cl<sub>2</sub> + 20 mL·min<sup>-1</sup> O<sub>2</sub> (1.34 g·m<sup>-2</sup>·h<sup>-1</sup>) under a constant Ar flow rate of 170 mL·min<sup>-1</sup> at 600℃ for 8 h. The surface morphology analysis results revealed that porous surfaces with tunnel-type holes were produced under the Cl<sub>2</sub>-O<sub>2</sub> mixed-gas condition. Furthermore, the effects of the Cl<sub>2</sub> flow rate on the corrosion rate were investigated, indicating that its impact was negligible within the range of 5-30 mL·min<sup>-1</sup> Cl<sub>2</sub> at 600℃.

      • SCOPUSKCI등재

        Ultrasonic Degradation of Endocrine Disrupting Compounds in Seawater and Brackish Water

        So Young Park,Jong Sung Park,Ha Yoon Lee,Ji Yong Heo,Yeo Min Yoon,Kyung Ho Choi,Nam Guk Her 대한환경공학회 2011 Environmental Engineering Research Vol.16 No.3

        In this study, a series of experiments was conducted on the relative degradation of commonly known endocrine-disrupting compounds such as bisphenol A (BPA) and 17α-ethinyl estradiol (Ee₂) in a single-component aqueous solution using 28 and 580 kHz ultrasonic reactors. The experiments were conducted with three different types of model water: deionized water (DI), synthetic brackish water (SBW), and synthetic seawater (SSW) at pH 4, 7.5, and 11 in the presence of inert glass beads and humic acids. Significantly higher sonochemical degradation (93-97% for BPA) occurred at 580 kHz than at 28 kHz (43-61% for BPA), regardless of water type. A slightly higher degradation was observed for Ee₂ compared to that of BPA. The degradation rate of BPA and Ee₂ in DI water, SBW, and SSW after 30 min of ultrasound irradiation at 580 kHz increased slightly with the increase in pH from 4 (0.073-0.091 min-1 for BPA and 0.081-0.094 min-1 for Ee₂) to 7.5 (0.087-0.114 min-1 for BPA and 0.092?0.124 min-1 for Ee₂). In contrast, significant degradation was observed at pH 11 (0.149-0.221 min-1 for BPA and 0.147-0.228 min-1 for Ee₂). For the given frequencies of 28 and 580 kHz, the degradation rate increased in the presence of glass beads (0.1 mm and 25 g) for both BPA and Ee₂: 0.018-0.107 min-1 without beads and 0.052-0.142 min-1 with beads for BPA; 0.021-0.111 min-1 without beads and 0.054-0.136 min-1 with beads for Ee₂. A slight increase in degradation of both BPA and Ee₂ was found as the concentration of dissolved organic carbon (DOC, humic acids) increased in both SBW and SSW: 0.107-0.115 min-1 in SBW and 0.087-0.101 min-1 in SSW for BPA; 0.111-0.111 min-1 in SWB and 0.092-0.105 min-1 in SSW for Ee₂. After 30 min of sonicating the humic acid solution, DOC removal varied depending on the water type: 27% (3 mg L-1) and 7% (10 mg L-1) in SBW and 7% (3 mg L-1) and 4% (10 mg L-1) in SSW.

      • KCI등재

        태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-

        이봉효 ( Bong Hyo Lee ),이경민 ( Kyung Min Lee ),박지하 ( Ji Ha Park ),김민서 ( Min Seo Kim ),김산들 ( San Deul Kim ),박병규 ( Byeong Gyu Park ),양현동 ( Hyun Dong Yang ),예성호 ( Sung Ho Yea ),이호정 ( Ho Jung Lee ),최재원 ( Jae 경락경혈학회 2012 Korean Journal of Acupuncture Vol.29 No.2

        Objectives: This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods: The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographi change was evaluated using paired t-test and post hoc Wilcoxon test. Results: The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions: The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.

      • SCIESCOPUSKCI등재

        Determining the Optimal Cooking Time for Cooking Loss, Shear Force, and Off-Odor Reduction of Pork Large Intestines

        Sung-Su Kim,Yee Eun Lee,ho Hyun Kim,Joong-Seok Min,Dong Gyun Yim,Cheorun Jo 한국축산식품학회 2022 한국축산식품학회지 Vol.42 No.1

        The objective of this study was to determine the optimal cooking time by considering the cooking loss, shear force, and off-odor reduction of pork large intestines. Commercial pork large intestines were purchased, quartered perpendicularly, and cooked in boiling water for 40, 120, 180, and 240 min. Cooking loss of the samples increased after 240 min of cooking (10.92, p<0.05) while shear force value was lower at 240 min (4.45) compared to that at other cooking times (p<0.001). The amount of major volatile organic compounds showed a decreasing trend with increasing cooking time. In particular, the amount of methyl pentanoate (17,528.71) and methyl isobutyrate (812.51), compounds with a relatively low odor threshold, decreased significantly after 120 min of cooking and no change was observed thereafter (p<0.05). In addition, the amount of 2-pentanol (3,785.65) and 1-propanol (622.26), possibly produced by lipid oxidation, significantly decreased at the same cooking time (p<0.001). In the principal component analysis, only the 40 min cooking time was significantly different from other cooking time by high amounts of 1-propanol, 2-pentanol, and methyl isobutyrate. In conclusion, in the present study, the optimal cooking time for pork large intestines was 120 min in terms of off-odor reduction, cooking loss, and shear force.

      • KCI등재
      • KCI등재

        Effect of Jaeumkanghwatang (JEKHT), a Polyherbal Formula on the Pharmacokinetics Profiles of Tamoxifen in Male SD Rats (1) - Single Oral Combination Treatment of Tamoxifen 50 mg/kg with JEKHT 100 mg/kg within 5 min -

        Kwak, Min A,Park, Soo Jin,Park, Sung Hwan,Lee, Young Joon,Ku, Sae Kwang The Society of Korean Medicine 2016 대한한의학회지 Vol.37 No.2

        Objectives: The objective of this study was to elucidate the effect of Jaeumkanghwatang (JEKHT) on the plasma concentration and pharmacokinetics of tamoxifen in combination therapy as a process of the comprehensive and integrative medicine against breast cancer. Methods: After 50 mg/kg of tamoxifen treatment, JEKHT 100 mg/kg was orally administered within 5 min. The plasma were collected at 30 min before administration, 30min, 1, 2, 3, 4, 6, 8 and 24 hrs after end of JEKHT treatment, and plasma concentrations of tamoxifen were analyzed using LC-MS/MS methods. PK parameters of tamoxifen ($T_{max}$, $C_{max}$, AUC, $t_{1/2}$ and $MRT_{inf}$) were analysis as compared with tamoxifen single administered rats. Results: JEKHT did not influenced on the plasma concentrations and pharmacokinetics of tamoxifen after single oral co-administration, within 5min except for some negligible effects on plasma concentration. The $T_{max}$, $C_{max}$, AUC, $t_{1/2}$ and $MRT_{inf}$ of tamoxifen in co-administered rats were quite similar to those of tamoxifen single treated rats. Conclusions: Based on the results of the present study, JEKHT did not influenced on the oral bioavailability of tamoxifen, when they were single co-administered within 5min. However, more detail pharmacokinetic studies should be tested to conclude the possibilities that can be used as comprehensive and integrative therapy with JEKHT and tamoxifen for breast cancers, when they were co-administered, like the effects on the pretreatment of JEKHT and after repeat co-administrations.

      • SCOPUSKCI등재

        COPA(cuffed oropharyngeal airway)를 이용한 마취 유도 시 근이완제 사용 유무에 따른 반응

        김상태,배진호,김상범,임승운,민병상,신영덕 대한마취과학회 2000 Korean Journal of Anesthesiology Vol.38 No.3

        Background : COPA (cuffed oropharyngeal airway) is a convenient device for airway management in patients undergoing general anesthesia for elective surgery in supine position. It causes less pharyngeal trauma than LMA(Laryngeal mask airway). The purpose of this study was to compare the effect of COPA with and without muscle relaxant. Methods : Forty patients with ASA physical status I and II for elective surgery were randomly assigned to two groups. Anaesthesia was induced with propofol (2 mg/kg) and vecuronium (1.5 mg/kg) and was administered intravenously in Group I but not in Group II. Mask ventilation was done for 5 min with 0: 5 L/min. COPA was placed and heart rate, and systolic, mean, diastolic blood pressure and peak inspiratory pressure were measured at 1 min interval for 5 min. Anaesthesia was maintained with pro- pofol 150 ㎍/kg/min, fentanyl 1 ㎍/kg/hr, O_2 2 L/min and N_2O 2 L/min. Results : There were no significant differences between Group I and Group II in heart rate, systolic, mean and dstolic blood pressure. PIP (Peak inspiratory pressure) was increased and hiccups occurred significantly (p $lt; 0.05) in Group II. Complete airway obstruction occurred in one patient of Group I and severe coughing, body movements and gagging occurred during induction and insertion in Group II. conclusions : With the use of appropriate muscle relaxant, we can use COPA without increased inspiratory pressure or significant complication. (Korean J Anesthesiol 2000; 38: 399~403)

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼