http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
( Hee Jun Cho ),( Byung Moo Oh ),( Jong-tae Kim ),( Jeewon Lim ),( Sang Yoon Park ),( Yo Sep Hwang ),( Kyoung Eun Baek ),( Bo-yeon Kim ),( Inpyo Choi ),( Hee Gu Lee ) 한국미생물 · 생명공학회 2019 Journal of microbiology and biotechnology Vol.29 No.2
Interleukin-21 is a common γ-chain cytokine that controls the immune responses of B cells, T cells, and natural killer cells. Targeting IL-21 to strengthen the immune system is promising for the development of vaccines as well as anti-infection and anti-tumor therapies. However, the practical application of IL-21 is limited by the high production cost. In this study, we improved IL-21 production by codon optimization and selection of appropriate signal peptide in CHO-K1 cells. Codon-optimized or non-optimized human IL-21 was stably transfected into CHO-K1 cells. IL-21 expression was 10-fold higher for codon-optimized than non-optimized IL-21. We fused five different signal peptides to codon-optimized mature IL-21 and evaluated their effect on IL-21 production. The best result (a 3-fold increase) was obtained using a signal peptide derived from human azurocidin. Furthermore, codon-optimized IL-21 containing the azurocidin signal peptide promoted IFN-γ secretion and STAT3 phosphorylation in NK-92 cells similar to codon-optimized IL-21 containing original signal peptide. Collectively, these results indicate that codon optimization and azurocidin signal peptides provide an efficient approach for the high-level production of IL-21 as a biopharmaceutical.
악성 혈액질환에서 성공적인 동종골수이식 후 숙주 기질 미세환경의 구축
조상희,이제중,남찬은,최경상,정익주,이일권,김진희,박종태,김형준 대한조혈모세포이식학회 2002 대한조혈모세포이식학회지 Vol.7 No.1
인체의 골수는 간엽모세포를 함유하고 있으며 이들은 골수미세환경의 주된 세포들로 분화가 가능하여 조혈기능을 지지한다. 본 연구에서는 성별이 다른 동종조혈모세포이식 환경에서 조혈모세포의 완전 생착을 보이고, 이식 후 1년에서 8년이 지난 11예의 재생불량성 빈혈 및 백혈병 환자들을 대상으로 하여 골수에서 MSC를 분리하고 체외 확장을 통해 배양된 MSC에서 X 염색체 탐식자를 이용한 FISH 및 microsatellite polymorphism PCR 기법으로 그 기원을 확인하였다. 그 결과 조혈모세포는 완전히 공여자 기원으로 대치되었음에도 불구하고 MSC는 모두 수여자 기원임을 알 수 있어, 동종조혈모세포이식에서 미세환경의 구축은 수여자의 자가 생산에 의한 골수 간질세포에 의한 것으로 생각된다. Background: Human bone marrow (BM) contains mesenchymal stem cells (MSC) that can differentiate into various cells of mesenchymal origin. It remains a matter of controversy whether donor-derived stromal cells are capable of engraftment following hematopoietic stem cell transplantation (HSCT) or not. Methods: To determine if donor-derived stromal cells are transferred to the recipients of allogeneic HSCT, we investigated the characterization of MSC in 11 patients 1 to 8 years after sex mis-matched allogeneic HSCT in severe aplastic anemia and leukemia. Results: All patients had complete engraftment with donor- derived stem cells as shown by detection of donor type DNA in peripheral blood mononuclear cells. Following culture, MSC showed the expression of SH2 and SH4, but none of the hematopoietic markers of CD14, CD34, or CD45. MSC which can be differentiated to osteogenic lineage showed the genotype of recipient completely using FISH or PCR analysis. Conclusion: This study confirmed that MSC isolated from recipients of allogeneic HSCT in severe aplastic anemia and leukemia are not of donor genotype despite of full hematopoietic engraftment with donor type. Donor cells did not contribute to reconstitute the marrow microenvironment.
조태희,최경규,박상혁,박상진 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.3
The objectiveness of this study was to evaluate whether low-viscosity composite can bond effectively to dentin surface without bonding resin. The low-viscosity composites being 50wt% filler content were made by the inclusion of bonding resin of two self-etching systems(Clearfil SE Bond, Unifil Bond) varied with contents as 0, 10, 20, 30, 40, 50wt%. Exposed dentin surfaces of extracted 3rd molars are used. Dentin bond strengths were measured. The tests were carried out with a micro-shear device placed testing machine at a CHS of 1mm/min after a low-viscosity composite was filled into an iris cut from micro tygon tubind with internal diameter approximately 0.8mm and height of 1.0mm. 1. Flexural strength and modulus was increased with the addition of bonding resin. 2. Micro-shear bond strength to dentin was improved according to content of bonding resin irrespective of applying or not bonding resin in bonding procedure, and that of Clearfil SE Bond groups was higher than Unifil Bond. 3. There were no significant difference whether use of each bonding resin in bonding procedure for S-40, S-50, U-50(p>0.05). 4. In SEM examination, resin was well infiltrated into dentin after primed with self-etching primer only for S-50 and U-50 in spite of the formation of thinner hybrid layer. Low viscosity composite including some functional monomer may be used as dentin bonding resin without an intermediary bonding agent. It makes a simplified bonding procedure and foresees the possibility of self-adhesive restorative material.
폴리에스테르 섬유 감량시스템용 프로세서 타이트레이터 개발
조진호,이흥락,이종현,김명남,구성모,김무영,진경찬,유병희,강민수,김국진 경북대학교 센서기술연구소 1993 연차보고서 Vol.1993 No.-
폴리에스테르 섬유 감량시스템의 제어를 위해서는 처리조 내에서 감량되는 섬유가 목표 감량치에 도달했는지를 판단해 주는 장치가 필요하다. 본 연구에서는 가성소다용액의 초농도 및 섬유 감량 정도의 정확한 측정과 감량 종료시간의 산출 및 이에 따른 종료신호를 발생할 수 있는 폴리에스테르 섬유 감량기 전용의 자동적정장치를 개발하였다. To control caustic soda treatment system for the polyester fabric reduction, we need the device to determine that the fabric has been arrived target reduction value. In this study, we develope an automatic process titrator for the caustic soda treatment system. Major functions of the target titrating system are accurate measurements of the caustic soda concentration and then producing the end point signal for caustic soda treatment system.
광섬유 방사선 센서와 EBT 필름을 이용한 심부선량 백분율 측정 및 비교
조동현,장경원,유욱재,신상훈,이봉수,문주현,박병기 제주대학교 방사선응용과학연구소 2008 방사선응용과학연구소논문집 Vol.22 No.-
In this study, fiber-optic sensor is fabricated to measure PDD of CLINAC. As a scintillating light generated by a high energy X-ray from the medical LINAC is measured using photo diode amp system, It is expected that a high-resolution, real-time fiber-optic dosimeter for medical LINAC can be developed.
事務所建物의 리모델링活性化를 위한 諸般事項 定立에 관한 硏究
조균형,최두성,이경수 대한건축학회 2003 대한건축학회논문집 Vol.19 No.9
Nowadays, remodeling has been understood as a countermeasure to improve indiscriminate construction behavior in the aspect of environment and economy. Remodeling is able to retrench the resources and costs consumed in construction and the wastes from demolition of building. On the other hand, remodeling makes negative impacts from misunderstanding for the concept of remodeling. For reasons mentioned above, this study took the two-pronged approach consisting of the examination of the existing remodeling construction data of office buildings from the five domestic remodeling companies and the survey of the concerned departments and the employees at the architect's offices. The research content mainly included the demand cycle of remodeling, the type and scope of remodeling construction, analysis of construction costs, and problems in construction. Further, the environmental impacts from construction were quantified by Life Cycle Assesment.
이중에너지 방사선 흡수계측법을 이용한 성인 남녀의 장골 및 경골의 골밀도에 관한 연구
조용석,김경원,이경호,박현진,서상수,오상엽 대한악안면성형재건외과학회 2000 Maxillofacial Plastic Reconstructive Surgery Vol.22 No.3
Purpose : The aim of this study was to evaluate the bone mineral density of iliac and tibial bone which are frequently selected as autogenic bone graft donor sites, and to evaluate the efficiency of this method as a guideline for the selection of bone graft donor site. Materials and Methods : In this study 61 male and 70 female volunteers at Chungbuk National University Hospital were involved between Jan. 1998 to Sept. 1999. We measured bone mineral density of the iliac and the tibial bone using dual energy X-ray absorptiometry. We evaluated the data using the SAS system for Windows and bone mineral density of the lumbar was used for control. Results : Age showed the highest correlation in correlation matrix between physical and bone variables. Height and weight showed lower correlation of linear increment. In man, the change of bone density according to age demonstrated linear decrease irrespective of the lumbar, ilium, and tibia. In woman, the change of bone density according to age showed cubic form, which increased in the third and forth decade. So it had a peak bone mass on about 35 year-old, thereafter, the change of bone density slowly decreased until 50 year-old, but it rapidly decreased after 50 year-old and it slowly decreased again after 65 year-old. Both in all subjects and subject with osteoporosis, the change of bone mineral density according to age showed statistically significant decrease in lumbar and tibia, but ilium was irrespective. Conclusion : In patients of aged or with osteoporosis, ilium demonstrated less tendency of decrease in bone mineral density than tibla. So this preliminary study suggested that ilium seemed better donor site for autogenic bone graft than tibia.
조영호,유벙전,서영환,조경상,김상도,정춘해 朝鮮大學校 附設 醫學硏究所 1992 The Medical Journal of Chosun University Vol.17 No.2
Polycythemia vera is one of the myeloproliferative diseases, and as such, is an example of clonal hematopoiesis. The progeny of a single, abnormal, hematopoietic stem cell gain a grwoth advantage over their normal counterparts resulting in overproduction of red cells generally accompanied by overproduction of granulocytes and platelets as well. There are a variety of nonspecific symptoms at onset related to the increased red cell mass and hematocrit accompanied by the more specific manifestations of pruhtis, erythromelalgia, and hepatic, portal, and mesenteric vein thrombosis. Splenomegaly and hypertension are common. Thrombosis and leukemia are frequent complication in polycythemia vera and are associated with severa organ damage and a high mortality. We report here the case of occurrence of myocardial and cerebral infarction in a patient with polycythemia vera.