RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        Three-Dimensional Porous Collagen/Chitosan Complex Sponge for Tissue Engineering

        Kim, Sung Eun,Cho, Yong Woo,Kang, Eun Jung,Kwon, Ick Chan,Lee, Eunhee Bae,Kim, Jung Hyun,Chung, Hesson,Jeong, Seo Young The Korean Fiber Society 2001 Fibers and polymers Vol.2 No.2

        A three-dimensional, porous collagen/chitosan complex sponge was prepared to closely simulate basic extracellular matrix (ECM) constitutes, collagen and glycosaminoglycan. The complex sponge was prepared by a lyophilization method and had the regular network with highly porous structure, suitable for cell adhesion and growth. The pores were well interconnected, and their distribution was fairly homogeneous. The complex sponge was crosslinked using 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) to increase its boilogical stability and enhance its mechanical properties. The crosslinking medium has a great effect on the inner structure of the sponge. The homogeneous, porous structure of the sponge was remarkably collapsed in an aqueous crosslinking medium. However, the morphology of the sponge remained almost intact in a water/ethanol mixture crosslinking milieu. Mechanical properties of the collagen/chitosan sponge were significantly enhanced by EDC-mediated crosslinking. The potential of the sponge as a scaffold for tissue engineering was investigated using a Chinese hamster ovary cell (CHO-K1) line.

      • KCI등재후보

        2003년 국내 중증급성호흡기증후군 진료 현황 및 문제점 분석

        이진수,김은실,정문현,백제중,정선화,안주희,최영화,이선희,고철우,김성범,김민자,박승철,기현균,송재훈,최상호,김양수,이상오,조용균,박영훈,정숙인,김연숙,이흥범,손창희,장성희,정희진,김우주 대한감염학회 2004 감염과 화학요법 Vol.36 No.3

        목적 : 2002년 말 중국에서 SARS가 발생한 이후 국내에서도 2003년 10월까지 총 3명의 추정환자, 17명의 의심환자가 보고되었다. 향후 추가적인 SARS의 유행이 우려되는 상황에서, 그간의 SARS 환자 진료에 있어서의 실질적인 준비사항, 진료 현황 등에 대한 조사를 통해 문제점을 파악하여, 향후 더 나은 대비가 될 수 있도록 개선점을 제시하고자 하였다. 재료 및 방법 : SARS로 의심되는 환자를 진료 경험이 있는 병원의료진을 대상으로 2003년 10월에 설문조사를 실시하였다. 설문에는 SARS 환자 진료 시의 실질적인 조치, 진료 현황, 병실, 응급실 및 외래에서의 격리 시설과 준비사항, 보건당국의 관리와 지원에 관한 사항을 포함하였다. 결과 : 대상이 되는 22개 병원 중 17개(17/22, 77.2%) 병원이 설문에 응하였다. SARS 환자를 위한 격리실은 응급실, 외래, 일반병실 및 중환자실에서 각각 9개(9/17, 52.9%), 5개(5/17, 29.4%), 15개(15/16, 93.7%), 4개(4/16, 25%) 병원에서 음압처리가 되어있지 않은 일인실 혹은 다인실이 사용되었고, 1개(1/16, 6.3%) 병원에서만 일반병실에서 음압격리실이 운영되었다. 입원환자의 진찰 시 개인보호구의 착용은 거의 모든 의료기관에서 이루어졌다. 보건당국에서 SARS지정병원의 시설 등을 사전에 확인한 곳은 1곳(1/12, 8.3%)이였고, 14개 병원(14/15, 93.3%)에서는 보건당국에 의뢰한 검사결과를 통하 받지 못하였다. 결론 : 의료기관에서 SARS 환자용 격리실뿐만 아니라 기존의 격리실 설비 등이 미흡하였으며, 특히 중환자실 및 외래의 준비가 더욱 부족하였다. 보건당국의 의료기관에 대한 종합적인 지원이 부족하였고, 병원과의 원활한 연계가 잘 이루어지지 않았다. SARS 만이 아닌 격리를 필요로 하는 질환의 적절한 진료를 위해 향후 병원 시설의 정비와 정부차원에서의 보다 구체적이고 실질적인 대책마련이 필요하다. Background : There was an worldwide outbreak of the Severe Acute Respiratory Syndrome (SARS) originated from China in late 2002. During that period three cases of suspected SARS and 17 cases of probable SARS were reported in Korea. With the concerns about the reemergence of SARS-coV transmission, it is important to be prepared for any possibility. So, this study is aimed to analysis the past measures in managing SARS and propose the amendatory plans to improve the preparedness. Materials & Methods : Questionnaires were collected among clinicians with any experience in managing the probable or suspected SARS cases in Oct. 2003. 17 out of 22 hospitals responded to the questionnaire. The contents in the questionnaire were practical activities, personal equipments, response plans, isolation facilities in emergency centers, outpatient clinics, general wards and intensive care units, and relationship with the public health department. Results : The dedicated isolation rooms in emergency centers, outpatient clinics, general wards, and intensive care units were prepared in 9 (9/17, 52.9%), 5 (5/17, 29.4%), 15 (15/16, 93.7%), and 4 (4/16, 25.0%) hospitals, respectively. Except for one hospital that newly made negative pressure room for SARS, single or multi-bed rooms without airborne infection control were used in all the other hospitals. The personal precaution principles were kept quite well in general wards. Before the designation of SARS hospital by the public health department prior evalution to see if the hospital was suitable for managing SARS was conducted in only 1 (1/12, 8.3%) hospital. The results of laboratory diagnosis were reported back in 1 (1/15, 6.6%) hospital. Conclusions : The isolation facilities which can control airborne infection were almost deficient not only for SARS but also for other respiratory transmissible diseases. For the infection control of transmissible diseases including SARS, more investment is needed on medical facilities and comprehensive support from the public health department required.

      • KCI등재

        한국인 직무 스트레스 측정도구의 개발 및 표준화

        장세진,고상백,강동묵,김성아,강명근,이철갑,정진주,조정진,손미아,채창호,김정원,김정일,김형수,노상철,박재범,우종민,김수영,김정연,하미나,박정선,이경용,김형렬,공정옥,김인아,김정수,박준호,현숙정,손동국 大韓産業醫學會 2005 대한직업환경의학회지 Vol.17 No.4

        Background and Purposes: Over the past three decades, numerous studies performed in Korea have reported that job stress is a determinant risk factor for chronic diseases and work disability. Every society has its own culture and occupational climate particular to their organizations, and hence experiences different occupational stress. An occupational stress measurement tool therefore needs to be developed to estimate it objectively. The purpose of this study is to develop and standardize the Korean Occupational Stress Scale (KOSS) which is considered to be unique and specific occupational stressors in Korean employees. Subjects and Methods: Data were obtained from the National Study for Development and Standardization of Occupational Stress (NSDSOS Project: 2002-2004). A total of 12,631 employees from a nationwide sample proportional to the Korean Standard Industrial Classification and the Korean Standard Occupational Classification were administered. The KOSS was developed for 2 years (2002-2004). In the first year, we collected 255 items from the most popular job stress measurement tools such as JCQ, ERI, NIOSH and OSI, and 44 items derived from the a qualitative study (depth interview). Forty-three items of KOSS, in the second year, were retained for use in the final version of the KOSS by using Delphi and factor analysis. Items were scored using conventional 1-2-3-4 Likert scores for the response categories. Results: We developed eight subscales by using factor analysis and validation process: physical environment (3 items), job demand (8 items), insufficient job control (5 items), interpersonal conflict (4 items), job insecurity (6 items), organizational system (7 items), lack of reward (6 items), and occupational climate (4 items). Together they explained 50.0% of total variance. Internal consistency alpha scores were ranged from 0.51 to 0.82. Twenty-four items of the short form of the KOSS (KOSS-SF) were also developed to estimate job stress in the work setting. Because the levels of the subscales of occupational stress were gender dependent, gender-specific standard norms for both the 43-item full version and the 24-item short form using a quartile for the subscales of KOSS were presented. Conclusion: The results of this study suggest that KOSS might be an appropriate measurement scale to estimate occupational stress of Korean employees. Further and more detailed study needs to be conducted to improve the validity of this scale.

      • 고등어 및 정어리 선어의 휘발성성분

        조우진,김훈,정연정,이영미,정은정,차용준 창원대학교 생활과학연구소 2002 생활과학연구 Vol.- No.6

        This study was conducted to identify volatile compounds, associating with quality deterioration, which may play roles as indicators for quality assessment in fresh mackerel and sardine. Volatile compounds were analyzed by liquid liquid continuous extraction(LLCE)/GC/MSD methods. A total of 83 and 81 volatile compounds were detected in fresh mackerel and sardine, respectively, and these compounds were mainly composed of aldehydes(12 in raw mackerel, 11 in raw sardine), ketones(7, 4), alcohols(15, 14), esters(1, 3), aromatic compounds(13, 15), terpenes(5, 7), S-containing compounds(2, 2), hydrocarbons(13, 11) and miscellaneous compounds(2, 1). Most of compounds including carbonyls, alcohols, aromatic compounds and hydrocarbons were derived from lipid oxidation, and some compounds were detected from microbial degradation. It was supposed that LLCE method was proper to seek indicators for quality assessment in fresh mackerel and sardine, because of various volatile compounds derived from nonthermal lipid oxidation.

      • 슬라이딩 관측기를 이용한 유도전동기의 센서리스 제어

        우정인,조용길,신동률,박지호 東亞大學校 附設 情報通信硏究所 1999 情報通信硏究所論文誌 Vol.7 No.1

        In this paper, the robust vector control method of Induction Motor for the purpose of improving the system performance deterioration caused by parameter variations is proposed. The full order state observer estimates the stator surrent and the rotor flux by using the state prediction of state variables. And, the motor speed is estimated without without speed using the full order state observer. Also, the parameter variation is compensate by the Sliding Observer. By using this method, speed sinsorless control and current contol with no affection of the parameter variation can be obtained simultaneously.

      • DSP 인버터에 의한 편측식 선형 유도전동기의 비간섭제어

        우정인,신동률,조용길,노인배,정영일 東亞大學校 附設 情報通信硏究所 1998 情報通信硏究所論文誌 Vol.6 No.1

        We proposed the speed control of the inverter-fed SLIM(Single-sided Linear Induction Motor) for conveyance system by the decoupled thrust control with DSP board. The voltage equations of SLIM are expressed on the suitable α-β axis by the proposed equivalent circuits, which can analyze the characteristics of the thrust and the normal force and so on. These control methods, which are the slip angular frequency control and the decoupling control for the thrust and normal force by analyzing these parameters can be successfully driven without interfering of each axis. These results exemplified the linear drive of SLIM with the reference value.

      • KCI등재

        생체내 심근허혈-재관류 모델에서 멜라토닌의 재관류 부정맥에 대한 심근보호작용에 관한 연구

        조규종,김원,홍정석,이미우,장성은,오세현,임경수 대한응급의학회 2001 대한응급의학회지 Vol.12 No.4

        Background: Recently, a few studies demonstrated that melatonin reduced the severity of myocardial reperfusion injuries, such as reperfusion arrhythmias. However, it is uncertain whether the melatonin reduces reperfusion arrhythmias in thus anesthetized animals because results were obtained using isolated hearts. Thus, to see whether melatonin reduces reperfusion arrhythmias in anesthetized animals, we examined the effect of melatonin on the incidence of reperfusion arrhythmias in an anesthetized-cat model of regional ischemia. Method: Adult mongrel male cats(n=30, 2.9∼4.2 kg) were anesthetized under positive-pressure artificial ventilation with room air. The animals of the control group(n=15) were subjected to 20-minute left anterior descending coronary artery(LAD) occlusion followed by abrupt reperfusion. The animals in experimental group(n=15) were divided into two. Group I(n=6) was pretreated with melatonin, 1 mg/kg, before occluding the LAD. Group II(n=9) was pretreated with melatonin, 10 mg/kg. The animals in experimental group were subjected to ischemia/reperfusion insult following drug treatment: melatonin was applied intra-peritoneally for 3 minutes just before LAD coronary artery ligation. The Fisher's exact test was used to compare the data from different animal groups. p<0.05 was considered significant. Results: The incidence of ventricular fibrillation(VF) during the reperfusion phase in group II(pretreated with melatonin, 10 mg) was significantly smaller than that in the control group(p-value = 0.0029). However, no statistically significant difference of VF incidence was found between group I(pretreated with melatonin, 1 mg) and the control group. Conclusion: Employing an anesthetized-cat model of regional cardiac ischemia, we investigated the dose-dependant effects of melatonin on reperfusion-induced arrhythmia. The cats pretreated with 10 mg/kg of melatonin before ischemia had a significantly reduced incidence of lethal reperfusion-induced arrhythmia, but there was no difference between the cats pretreated with 1 mg/kg of melatonin before ischemia and the control group.

      • 반송용 선형 유도 전동기의 급속 제동특성에 관한 연구

        우정인,조윤현,노태균,신동률,이채동 東亞大學校 1996 東亞論叢 Vol.33 No.-

        The SLIM used in the conveyance system has been generally developed the controller based on the slip frequency control and the VVVF method to obtain the quirk response for the position control signal. This paper deals with the trust control of the SLIM by vector control with Bang-Bang condition. Also, the control system is composed of the Pl controller for soft start of the SLIM and the q-axis current controller for correction in phase with Space Vector for reducing the harmonic pulsation in low speed. The processing for vector control and robust dynamic breaking control is carried out by MC80196KC micro processor and IGBT module. The proposed scheme is verified through the computer simulation and experiments for the 10KW SLIM.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼