RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        소형엔진의 배출가스측정방법에 따른 질소산화물 및 매연에 관한 연구

        한영출,나완용,오용석,문병철,박봉규,박귀열 한국공작기계학회 2001 한국생산제조학회지 Vol.10 No.3

        Recently, increasing usage of diesel vehicle, many countries try to reduce the pollutant materials by emission regulation standard. Particularly, in our country, the supplement ratio of diesel vehicle is high, and air pollution by vehicle exhaust gas is very serious. So, in study, we tested exhaust gas by various mode in light duty diesel engine. Therefore, we can know about NOx and smoke seriousness.

      • 외상성 신동맥 색전증 1례

        한병규,김욱현,문기혁,송윤섭,박영호 순천향의학연구소 2004 Journal of Soonchunhyang Medical Science Vol.10 No.2

        Renal artery thrombosis may result from external trauma of a blunt nature. Such injury is induced by rapid deceleration resulting in the stretching of the renal vasculature, disruption of the arterial intima-the least elastic layer of the arterial wall and eventual thrombosis. The treatment of renal artery thrombosis is controversial, with physician's options divided between prompt surgical exploration with vascular repair and clinical observation. We experienced 1 case of traumatic renal artery thrombosis and report that with a brief review of the literature.

      • 새 교육과정의 물리교과 분석 연구

        한덕보,김규용 濟州大學校 師範大學 科學敎育硏究所 1989 科學敎育 Vol.6 No.-

        The new curriculum that is revised will be put into effect in 1990. The pur-pose of this thesis is to find out a desirable direction of physics education by ab-stracting the problem and suggesting the way of improvement through analyzing the contents of the physics curriculum in high school. The conclusion of this thesis is as follows ; 1 . The teacher should be encouraged to present his teaching with 15 percent of a class for experiment, and in this thesis I think that all the subjects, espe-cially technology and society, should be taught in connection with science. 2 . The completion unit of physics has been decreased together with the suc-cessive revision of curriculum. In the fifth curriculum, the time allotment of physics curriculum is also less than that of the 0th- curricula of science. 3 . There is no difference between the new textbook and the old textbook in contents. It is desirable that the contents of the new textbook should be remade up, with a view to closing connection with practical life, in many categories.

      • 3종류 잔골재를 조합 사용한 시멘트 모르터의 특성

        한천구,윤기원,박용규 청주대학교 산업과학연구소 2005 産業科學硏究 Vol.23 No.1

        This paper investigated the engineering properties of cement mortar mixed with more than two kinds of fine aggregate. For fresh mortar properties, unit volume weight is constant regardless of mixing content and type of fine aggregate. An increase in contents of natural fine aggregate and crushed fine aggregate resulted in an increase in flow, whereas an increase in recycled fine aggregate contents reduced flow. Gap between maximum flow in N_(3)C_(0)R_(0) and minimum flow in N_(0)C_(0)R_(3) exhibited about 12%. Compressive strength at 28 days ranged from 32 to 36 MPa in order for crushed fine aggregate, natural fine aggregate and crushed fine aggregate showed compressive strength comparable to that of crushed fine aggregate. An increase of fraction of recycled fine aggregate in mixed fine aggregate resulted in a decrease in compressive strength. For drying shrinkage, N_(0)C_(0)R_(3) had the largest drying shrinkage among various mixture type. The combination of large contents of recycled fine aggregate and small contents of natural and crushed fine aggregate had a large amount of drying shrinkage.

      • KCI등재후보

        점화시기 및 당량비 변화에 따른 CNG기관의 성능 및 배출가스에 관한 연구

        한영출,오용석,박봉규,김대열,김미수 한국공작기계학회 2001 한국생산제조학회지 Vol.10 No.4

        Research on the development of CNG dedicated en dine that has important meaning both as a clean fuel and an alterna-tive energy to reduce the exhaust emission horn diesel engine are actively going on these days. In this study, in order to present the direction and application of CNG engine, we tested the CNG engine performance experimented by changing the parameters such as ignition timing, equivalent ratio. The engine performance and exhaust emission were measured by engine performance mode at maximum load condition with increasing the rpm in the range of 1,000∼2,200rpm. Also, the testing engine was heavy-duty CNG dedicated engines with displacement of 11,050cc.

      • KCI등재

        터보 차져와 인터쿨러를 장착한 디젤기관의 시뮬레이션 연구

        한영출,백두성,류규현,오용석,박만재 韓國工作機械學會 2000 한국생산제조학회지 Vol.9 No.4

        Studies on the turbocharger itself or various aspects generated from turbocharged engine have been made. However, only a few researches have been made on the performance for the natural aspirated engine equipped with the turbocharger and the intercooler. In this study, the performance prediction program based on turbocharger theory is developed for simu-lation which may reduce the cost and the trial-and-error time. The program is verified with the experimental results for 11,000cc diesel engine with the turbocharger and the intercooler. Also, various factors which are invisible in experiment are predicted using this program.

      • 주택성능등급제에 따른 레미콘 산업의 대응방안

        한천구,이건철,오상백,박용규 청주대학교 산업과학연구소 2006 産業科學硏究 Vol.24 No.1

        This study investigates the regulations on concrete grade evaluation, in response to operation of housing performance grade system(HGS). It also studies countermeasure- of ready mixed concrete industry. Because the HGS provide people who have to invest in housing once during their whole life, with objective information of housing performance, housing consumers would easily understand and purchase better house. In addition housing construction companies will try to supply the high quality housing, in response to people's various housing performance needs. It is expected that housing quality improvement and housing components technology development will be nationally activated, due to the competition on housing quality between the construction companies. After this, HGS is now on design process but will be on construction process connecting specification, which is perfoiniance based design and on the process after completion. It is assumed that those regulations will be possibly continued to develope for housing performance guarantee system.

      • KCI등재
      • 직업적 연폭로에서 혈중 연량 수준에 따른 선별검사로서의 혈중 ZPP 검사의 타당도

        한구석,안현철,김용배,리갑수,김화성,황규윤,장봉기,이성수,안규동,이병국 순천향대학교 산업의학연구소 1999 순천향산업의학 Vol.5 No.1

        In order to evaluate the validity of current screening criteria of lead exposure and to provide effective information for the better health management of lead workers, author investigated the interrelationship between blood lead and blood zinc protoporphyrin(ZPP) and evaluate the validity of blood zinc protoporphyrin as the screening test and blood lead as gold standard of diagnostic test. The total of 2245 lead workers (male workers: 1982, female workers : 263) from 12 lead using industries were studied. Blood lead, ZPP, hemoglobin and hematocrit were selected as lead exposure variables. Personal information on sex, age and work duration were also checked. Blood lead was measured with flameless atomic absorption spectrometry (model: Hitachi 8100) using standard addition method. Blood ZPP was measured with portable hematoflurometer (model: Aviv 206). The results obtained were as follows: 1. The mean blood lead of all lead workers were 0.7±14.3㎍/㎗(Male: 31.0±14.4㎍/㎗, Female: 28.2±12.9㎍/㎗), whereas the mean blood ZPP of those were 68.1±47.5㎍/㎗(Male: 63.9±43.7㎍/㎗, Female: 100.1±61.0㎍/㎗). The mean value of hemoglobin and hematocrit of all lead workers were 14.5±1.5g/㎗(Male: 14.7±1.3g/㎗, Female: 12.3±1.2g/㎗) and 45.4±3.6(Male: 46.2±2.8, Female: 39.5±3.1) respectively. 2. Validity of test using blood zinc protoporphyrin as screening test for blood lead levels of 30㎍/㎗ as gold standard of diagnostic test revealed that the highest validity value for male and female lead workers were 50 and 90 ㎍/㎗ of ZPP respectively, showing 50 and 60 ㎍/㎗ of ZPP for all lead workers. While those test for blood lead levels of 40㎍/㎗ as gold standard of diagnostic test revealed that the highest validity value for male and female lead workers were 60 and 90 ㎍/㎗ of ZPP respectively, showing 60 ㎍/㎗ of ZPP for all lead workers, those test for blood lead levels of 50 and 60㎍/㎗ as gold standard of diagnostic test revealed that the highest validity value for male and female lead workers were 60 or 70 and 100 ㎍/㎗ ZPP respectively, showing 60and 70 or 80 ㎍/㎗ of ZPP for all lead workers. 3. Predictive value of test using blood zinc protoporphyrin as the screening test for different blood lead levels of 30, 40, 50 and 60㎍/㎗ as gold standard of diagnostic test revealed that positive predictive value of screening test were decreased by the increase of blood lead level regardless of csreening criteria value ZPP and negative predictive value of screening test were increased accordingly regardless of screening criteria value of ZPP. On the other hand, within same blood lead level as a gold standard positive predictive values were inceased by the increase of screening criteria value of ZPP, whereas the negative predictive value were decreased accordingly by the the increase of screening criteria value of ZPP. 4. The correlation analysis of all lead workers among study variables revealed that CPbB and natural log transformation ZPP(LZPP) were better correlated with other variables and found to be better estimate than PbB and ZPP themselves. The age was correlated with all other variables, but the work duration was not. The correlation analysis of male and female workers among study variables revealed the same results with all lead workers. 5. The slope of simple linear regression of CPbB (independent variable) with ZPP in female workers(3.223)was steeper than in male workers(2.144). That of lead workers with work duration of less than 1 year was steeper than that of lead workers whose work duration was more than 1 year. But there was no slope difference between two groups divided by their work duration of 2 years less and more. The slope of simple linear regression of CPbB lead (independent variable)with ZPP in lead workers whose blood lead were higher than 30㎍/㎗and 40㎍/㎗ were steeper than those whose blood lead were less than 30㎍/㎗ and 40㎍/㎗. 6. The slope of simple linear regression of CPbB (independent variable) with ZPP in lead industries with low mean blood lead were less steeper than those with high mean blood lead. 7. The slope of simple linear regression of CPbB (independent variable) with LZPP in female workers(0.0308was steeper than in male workers(0.0253). That of lead workers with work duration of less than 1 year was steeper than that of lead workers whose work duration was more than 1 year. But where was no slope difference between two groups divided by their work duration of 2 years less and more. While the slope of simple linear regression of CPbB lead (independent variable) with LZPP in lead workers whose blood lead were hogher than 30㎍/㎗ was not steeper than those whose blood lead were less than 30㎍/㎗, there was no slope difference between two groups whose blood lead were less than 40㎍/㎗ and more than 40㎍/㎗. 8. The slope of simple linear regression of CPbB (independent variable) with LZPP in lead industries with low mean blood lead were less steeper than those with high mean blood lead, but the difference was not significant then that of CPbB and ZPP. With above results, it is recommended that the screening criteria value of ZPP should be down to 60-70㎍/㎗ from 100㎍/㎗ for male lead workers and screening criteria of ZPP for female lead workers was all right with current value of 100㎍/㎗. So it is recommended to make different screening criteria of ZPP for male and female workers like the hemoglobin and hematocrit screening criteria. It is also preferable to use CPbB and LZPP rather than uncorrected PbB and ZPP in the evaluation of lead exposure for lead workers.

      • 금강의 수질, 어패류, 이끼 및 토양중의 중금속의 함량 조사

        한인전,홍춘표,최용규 공주대학교 사범대학 과학교육연구소 1993 과학교육연구 Vol.24 No.1

        This survey is to study the corresponding degree of water pollution of the Kum river areas, covering the eight places of main stream of the river from the Daechung dam to Kangkyung county, and two trivutary streams of Kap stream, and Miho stream. Besides, the heavy metal content of the fishes, shellfish, moss, and soil in the main stream of Kum river is investigated, whose results are as follows: 1. The water quality The water quality of the area from the Daechung dam to the Sintanjin county is first grade for the standard of drinking water in terms of BOD, COD values, that of both Kap stream and Miho stream is third or fourth grade respectively, and the other areas are turned out to be second grade. The water of the Daechung dam to the Sintanjin has little NO₂-N and ??, which can be said to be possible for the drinking water. The quantity of ?? and ?? in the water of all the areas is below the standard for the available drinking water, but, that of Kap stream and Miho stream is about two or three times higher than other areas. 2. Heavy metal The content of Cd, Cu, Mn, and Zn are shown to be comparatively less than that of Co, Fe, Ni, and Pb. And the content of Cu, Mn, Zn are less than the possible standard value for the drinking water. The relationship of the heavy metal content of the fish and shellfish were in order of Co>Zn>Cu>Cd, for the moss, Zn>Pb>Co>Cu>Cd, and for the soil, Zn>Pb>Cu>Co>Cd. The most of collecting samples in the Kumnam area have lots of heavy metals, and Pb is well contained in shells than fishes. When summarize the above result, the water in the Daechung dam and Sintanjin area is comparatively favorable for the drinking water, and the water quality below the Kumnam areas appears to be wores because of influx of Kap stream and Miho stream. In short, the necessary counter measure is to be required for the good preservation of water of fine quality in Kum River.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼