        초음파를 이용한 다양한 골절 진단

        류정규,진욱 대한초음파의학회 2008 ULTRASONOGRAPHY Vol.27 No.1

        The diagnosis of a bony fracture by the use of ultrasound is not common. However, with the advantage of the use of a realtime examination and recent technical advances, the use of ultrasound has gradually been on the increase. In this pictorial review, we demonstrate the sonographic findings of various kinds of bony fractures where an ultrasound examination was effective in the diagnosis of a fracture. The use of ultrasound is compared with the use of other imaging modalities. 초음파검사를 이용한 골절 진단은 보편화되어 있지 않으나 기기의 발달과 실시간 검사라는 장점으로 점차 적용이 확대되고 있다. 본 종설에서는 골절 진단에 초음파 검사가 유용하게 사용될 수 있는 여러 가지 골절들의 초음파 영상소견을 서술하고 다른 영상기법과 비교하고자 한다.

      • KCI등재

        Estimation of T2* Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System

        류정규,오장훈,김형기,Sun Jung Rhee,서미리내,장건호 대한자기공명의과학회 2014 Investigative Magnetic Resonance Imaging Vol.18 No.1

        Purpose : T2* relaxation time which includes susceptibility information represents unique feature of tissue. The objectiveof this study was to investigate T2* relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age 49 ± 12 years; range, 25to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 mssteps. Voxel-based T2* relaxation times and R2* relaxation rate maps were calculated by using the linear curve fitting foreach subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-timeimage to obtain T2* and R2* values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were 4818 ± 4679 voxels and 1455 ± 785 voxels for the normal glandular tissue and fat,respectively. The mean T2* values were 22.40 ± 5.61 ms and 36.36 ± 8.77 ms for normal glandular tissue and fat,respectively. The mean R2* values were 0.0524 ± 0.0134/ms and 0.0297 ± 0.0069/ms for the normal glandular tissueand fat, respectively. Conclusion: T2* and R2* values were measured from human breast tissues. T2* of the normal glandular tissue was shorterthan that of fat. Measurement of T2* relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

      • KCI등재

        유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구

        류정규,이선정,장건호 대한자기공명의과학회 2014 Investigative Magnetic Resonance Imaging Vol.18 No.1

        목적 : 유방암의 이중반전회복 자기공명영상 (double inversion recovery, DIR) 신호와 자기공명분광영상기법 (MR spectroscopy, MRS)에서 얻은 단일 화적소 콜린 양과 상관관계가 있는가를 알아보고자 하였다. 대상 및 방법 : 2008년 8월부터 2009년 12월까지 유방암으로 진단된 환자 중 이중반전회복 자기공명영상과 자기공명분광영상기법 모두를 시행한 28명의 환자를 대상으로 하였다. 이중반전회복영상과 조영증강 T1강조영상 (CE-T1WI)에서 종양에 해당하는 관심영역에서의 신호강도를 삼차원으로 얻었으며 병변 (L)과 동측 정상 섬유선 조직 (N)에 대한 용적을 같은 레벨에서 병변 대 정상조직의 신호강도 비 (LNR)를 구하였다. 자기공명분광영상 데이터는 단일복셀분광방법인 중점분해분광학을 이용하였다. 자기공명분광영상기법에서 총 콜린 공명의 높이, 폭, 면적과 조영증강 T1강조영상에서 병변 대 정상 조직의 신호강도 비 값, 그리고 이중반전회복 자기공명영상의 병변 대 정상조직의 신호강도비 값 간의 상관 관계에 대해 Pearson 상관분석을 시행하였고 유의수준은 p=0.05이었다. 결과 : 조영증강 T1강조영상의 병변 대 정상 조직의 신호강도 비 값과 자기공명분광영상기법에서 콜린의 높이 (r=-0.322, p= 0.094), 폭 (r=-0.233, p=0.232), 면적 (r=-0.309 p=0.109)값과, 또한 이중반전회복 자기공명영상의 병변 대정상 조직의 신호강도 비 값과 자기공명분광영상기법 콜린의 높이 (r=0.067, p=0.735), 폭 (r=-0.287, p=0.139), 면 적 (r=0.012 p=0.953) 값 사이에 상관성은 통계적으로 유의하지 않았다. 조영증강 T1강조영상의 병변 대 정상조직의신호강도 비 값과 이중반전회복 자기공명영상의 병변 대 정상조직의 신호강도 비 값 사이에서도 Pearson상관계수 0.186 으로 두 군간에 관련성은 없었다 (p=0.344). 결론 : 이중반전회복 자기공명영상에서 유방암의 병변 대 정상조직간 신호강도 비와 자기공명분광영상에서의 콜린 공명의 상대적인 양은 서로 상관관계를 보이지 않았다.

      • KCI등재

        전방 관절순 파열: 견관절 자기공명 관절조영술의 진단적 가치

        류정규,윤영철,경남,이용걸 대한영상의학회 2001 대한영상의학회지 Vol.45 No.1

        목적: 견관절 전방 관절순 파열 진단에 있어서 자기공명 관절조영술의 진단적 정확도를 알아보고자 하였다대상과 방법: 1996년 9월부터 2000년 2월가지 본원에서 견관절 동통과 불안정성의 병력이 있었던 환자 281명을 대상으로 견관절 자기공명 관절조영술을 시행하였고 이중, 관절경 및 수술을 시행한 154명의 환자. 157개의 견관절에서 자기공명 관절조영술에서의 전방 관절순 파열여부를 관절경 및 수술소견과 비교하였다(남녀의 비는 150:4, 평균 23.3세였다).자기공명 관절조영술을 얻은 후부터 수술가지의 기간은 0에서 230일가지 평균 20.9일이었다. 관절경 및 수술에서는 전방관절 순 파열을 그 위치에 따라 4가지로 분류하였고(A:4시-6시 전하방부 B: 2시-4시.중앙부, C: 1 2시-2시 전상방부 D 전후방향성 상관절순손상)자기공명 관절조영술 소견에서와 일치하지 않은 전방 관절순 파열의 위양성 및 위음성 병변에 대해 그 위치와 원인을 후향적으로 분석하였다. 결과: 자기공명 관절조영술은 전방 관절순 파열의 진단에 있어서 94%의 민감도와 90%의 특이도, 그리고 91%의 정확도를 보였다 관절경 및 수술소견에서 전방 관절순 파열은 157개의 견관절 중에서 62예 (39.5%)에서 진단되었고 62개의 병변중에서 A+B, A+B+C, A+B+C+D 위치에 각각 32예 (52%) ,9예 (15%) .13예 (21%)를 보였으며 A+B+D, B + C. B+D 위치에 각각 1예(2%) 2예(3%) 1예(2%)에 해당하였고 A와 C에 2예(3%)씩 있었다. 자기공명 관절조영술에서 10개의 위양성 병변중에서 7개는 국소병변(전방관절순의 1/3이하) 이었고(2예는 A위치, 3예는 B위치, 그리고 2예는 C위치) 나머지 3예는 A+B위치에 해당하였는데 이들은 자기공명 관절조영술에서 두꺼워지거나 변형된 부위에 일치하였다. 4예의 모든 위음성 병변은 국소 병변이었다(2예는 A 2예는 C) 결론: 자기공명 관절조영술은 전방관절순 파열의 진단에 있어서 높은 민감도, 특이도 및 정확도를 보였다. 하지만 국소병변에 있어서는 진단적 정확도가 비교적 낮게 나타났다. Purpose: To assess the accuracy of magnetic resonance(MRI arthrography in the diagnosis of anterior labral tear of the shoulder Materials and Methods: Between Semptember 1996 and February 2000, MR arthrography of the shoulder was performed in 281 patients with a history of shoulder pain or instability. Among this total, only 157 shoulders in 154 patients who underwent arthroscopy or open surgery 0 to 230 (average,20.9) days after MR arthrography were included in this study; the subjects comprised of 150 males and 4 females with an average age of 23.3 years. MR arthrographs of these 154 patients were analysed for the presence of anterior labral tears, and the findings were correlated with the arthroscopic and surgical findings. Anterior labral tear was classified as A to D according to its location, as determined by arthroscopy and surgery. (A=4 to 6 o'clock direction, anteroinferior; B =2 to 4 o'clock direction, central; C= 12 to 2 o'clock direction, anterosuperior; D = SLAP lesions). The retrospective analysis of MR arthrographs showing false-positive and negative findings was also undertaken.. Results: In the diagnosis of anterior labral tear, MR arthrography showed a sensitivity of 94%), a specificity of 90%) and an accuracy of 91%). Anterior labral tears were confirmed by arthroscopy or surgery in 62 of the 157 shoulders (39%). Among 62 lesions, two (3%) were observed in area A, 32(52%) in area A+ B, nine (15%) in area A+B+C, one(2%) in area A+B+D, 13(21%) in area A+B+C+D, two (3%) in area B+C, one(2%)1 in area B + D, and two(3%) in area C. Among ten false-positive cases, seven were focal lesions (two, three and two lesions in area A, B and C, respectivelyl, and in the remaining three cases, located in area A+ B, MR arthrography revealed thickening and deformation. All four false negatives were focal lesions (two in area A and two in area C). Conclusion: Other than in focal lesions, in which accuracy was relatively low, MR arthrography showed high sensitivity, specificity and accuracy in the diagnosis of anterior labial tear of the shoulder.

      • KCI등재

        유방초음파검사 및 환자용 모니터 설치에 대한 만족도 조사

        류정규,김현철,양달모 대한초음파의학회 2010 ULTRASONOGRAPHY Vol.29 No.1

        Purpose: The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. Materials and Methods: 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. Results: For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required,suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Conclusion: Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system. 목적: 유방초음파검사를 받는 환자들을 대상으로 유방초음파검사에 대한 기본적인 사항과 새로이 도입된 환자용 모니터에 대한 만족도를 설문 조사를 통해 알아보고 문제점 및 개선방향을 파악하고자 하였다. 대상과 방법: 새로운 환자용 모니터가 설치된 이후 3개월 동안 유방초음파실 에서 유방초음파검사를 받은 349명의 환자를 대상으로 설문을 하였다. 총 8문항으로 이루어져 있었으며 환자의 기본적인 사항에 대한 질문 (나이, 유방초음파검사를 받는 이유, 검사자의 성별에 대한 선호도,적절한 검사 소요시간)과 모니터에 대한 만족도에 대한 질문으로 나누어 답하도록 하였다. 전체 환자를, 증상이 없이선별검사를 위한 경우 (screening group) 와 다양한 증상과 목적을 위한 진단적 검사인 경우 (diagnostic group)로 나누어 설문조사 결과를 서로 비교하여 보았다. 환자용모니터 시청에 대한 만족도는 5점 척도를 사용하여 답하도록 하였다. 결과: 전체 환자 중 screening group이 124명이었고diagnostic group은 225명이었다. 유방초음파를 시행하는검사자에 대한 선호도를 묻는 질문에서, screening group 에서는 81.5%가, diagnostic group에서는 79.1%가 여자의사를 선호하는 결과를 보였다. 적절하다고 판단되는 유방초음파 소요시간에 대하여는 전체 응답자의 약70%가 5분에서 15분 정도를 선호하는 것으로 나타났다. 모니터 시청에 대한 만족도는, 평균 3.97점을 나타내어 비교적 높은만족도를 나타냈는데, group별로 3점 이상의 만족도를 보인 정도를 보면 screening group과 diagnostic group에서각각 88.7%와 94.2%를 보여 높은 만족도를 나타냈다. 결론: 유방초음파 검사를 받는 환자들은 약 5분에서 15분 정도의 검사시간과 여자 검사자를 선호하였다. 또한, 새로 도입된 환자용 모니터 시스템에 대한 높은 만족도를 보였다.

      • 홍수경보시스템을 위한 위성링크 설계

        류정규,김정호 한밭대학교 2009 한밭대학교 논문집 Vol.7 No.1

        VSAT 시스템은 중심지구국, 무궁화위성 그리고 다수의 단말지구국을 포함하는 성형망으로 구성 되고, 광범위한 데이터서비스를 제공할 수 있으며, 사용자의 사용목적과 용도에 따라서 여러 가지 형태의 위성전송망 구성이 가능하다 홍수경보망을 구성 시 최적의 전송품질을 구현하기 위한 위성링크설계는 한 국의 환경특성, 무궁화위성의 특성 그리고 VSAT 시스템의 특성을 고려하여 설계한다. VSAT 시스템은 디지털 데이터 전송용으로 인바운드(Inbound) 는 TDMA 아웃바운드 (Outbound) 는 TDM 전송방식을 이용 하였으며 중심국과 단말국의 크기는 각각 3.7m. 1.2m로 설계되었다. VSAT망에서 링크설계는 VSAT 망 에 할당된 위성 중계기 (Satellite Transponder) 의 출력전력 및 대역폭 범위 내에서 중심지구국(Hub Station) 과 단말지구국(Remote Station) 이 주어진 전송규격에 따라 정보를 효율적으로 전송할 수 있도록 설계하여, VSAT 망으로 홍수관리의 효율적 운영을 제안한다.