http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
외측연결형 임플란트 고정체의 경부 디자인이 임플란트 주위조직에 미치는 영향에 대한 전향적 예비 임상연구
배은빈(Eun-Bin Bae),이소현(So-Hyoun Lee),전영찬(Young-Chan Jeon),강은숙(Eun-Sook Kang),박상례(Sang-Rye Park),이진주(Jin-Ju Lee),허중보(Jung-Bo Huh) 대한치과의사협회 2017 대한치과의사협회지 Vol.55 No.11
This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with ‘s’ shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant survival rate, marginal bone resorption, bleeding, plaque, and complications were evaluated. The survival rate of NBS and BS group was 94.74% and 90.48%, respectively. There was no significant difference on marginal bone resorption, bleeding and plaque between the two groups (P>.05). Within the limits of the present study, implants with a concave neck design showed similar clinical results to implants with a straight neck design on the peri-implant tissue responses. Longitudinal clinical studies are necessary to confirm more effective clinical results.
배은빈(Eun-Bin BAE),나세웅(Se-Woong NA),한인우(In-Woo HAN),편용범(Yong-Beom PYEON),이경훈(Kyounghoon LEE) 전남대학교 어업기술연구소 2020 어업기술연구소보고지 Vol.13 No.1
Seaweed fulvescens (Capsosiphon fulvescens) is a High-Value-Added food that is highly likely to develop into various forms, such as drying and simple foods. However, the damage to fish farms caused by migratory birds that winter has increased, making it difficult to produce and supply stable. Therefore, in order to solve this problem, this study is to find the most effective sound source and distance to combat migratory birds by connecting sound reproducing device to stationary directional speaker and mobile directional speaker. The elimination effect of the difference in the output size of the two speakers in the same location is compared, analyzed, and a maritime experiment is conducted to suggest the most effective method for eradicating migratory birds.
나사풀림과 나사파절이 동반된 실패한 임플란트 고정성 보철물의 회복증례
배은빈(Eun-Bin Bae),신영근(Young-Gun Shin),전영찬(Young-Chan Jeon),정창모(Chang-Mo Jeong),윤미정(Mi-Jung Yun),이소현(So-Hyoun Lee),허중보(Jung-Bo Huh) 대한치과의사협회 2017 대한치과의사협회지 Vol.55 No.7
In the case of failed fixed implant prosthesis accompanied by abutment screw fracture, fractured screw fragment must be removed to use the existing implant fixtures. A 61-year-old male patient, who had a failed maxillary fixed implant prosthesis accompanied by three abutment screw fracture, hoped to reconstruct the maxillary implant prosthesis, while maintaining the existing implant fixtures. To use the existing implant fixtures, fractured screw fragments were removed. A maxillary implant overdenture using available existing implants was planned. Bar-attachment with Locator was used for implant splinting, denture stability, and retention. Final impression was taken after treatment of peri-implantitis. Jaw relation registration was taken to evaluate available interarch space for bar-attachment. After fabricating bar-attachment, centric relation was taken. Implant overdenture using bar-attachment with Locator was delivered after wax-denture evaluation. This case report showed that a satisfactory clinical result was achieved by implant overdenture using existing implant fixtures in a maxillary edentulous patient.
이유진,배은빈,정창모,이진주,김지영,허중보 대한치의학회 2017 Journal of korean dental science Vol.10 No.2
This case study was to report the possible increase in the denture retention and psychological relief using the implant-supported fixed prostheses in a completely edentulous patient. The implants were placed in the anterior portion of the mandible in a patient who had completely edentulous state following the extraction of residual abutment teeth, and consequently a distal extension removable partial denture was fabricated. The patient’s adaptation and satisfaction to the new prosthesis was monitored and confirmed in terms of masticatory function and esthetics, by restoring the oral condition similar to initial status before the residual teeth extraction. After 6 months, radiographic examination confirmed that both the abutment teeth and the implants were stable and well maintained. Considering the relatively short clinical follow-up period, however, continuous long-term monitoring was required.
상하악 전악 발거 환자에서 POP BOW 시스템의 교합평면 디지털 전이법을 이용한 3D 프린팅 임시 즉시의치의 수복 증례
박도현,배은빈,정인환,정창모,윤미정,허중보,이소현 대한턱관절교합학회 2022 구강회복응용과학지 Vol.38 No.3
모든 잔존치의 발거를 계획한 환자의 경우 최종 보철 제작 전 무치악으로 지내는 기간을 최소화하기 위해 미리 임시 즉시의치를 제작하게 된다. CAD/CAM 시스템을 이용하면 전통적 방식에서의 한계점들을 보완하여 진료실과 기공실에서의제작 과정을 간소화 시킬 수 있다는 장점이 있다. 하지만, 환자의 악간관계에 관한 정보를 정확하게 기공실의 디지털 네트워크로 전달하는 과정에서 오차가 발생하여 교합관계가 불안정하거나 비심미적인 보철물이 제작될 빈도가 높다는 단점도 있다. 이러한 문제점을 극복하기 위해 간단하고 정확한 POP BOW 시스템의 교합평면 디지털 전이법을 이용하여,상하악 전치부 잔존치 발거 후 심미적이고 기능적인 3D 프린팅 임시 즉시의치를 장착한 환자의 성공적인 증례를 보고하고자 한다.
서용호,배은빈,김정우,이소현,윤미정,정창모,전영찬,허중보 대한치과보철학회 2016 The Journal of Advanced Prosthodontics Vol.8 No.4
PURPOSE. The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS. Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS. Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION. The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.
부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례
황수현,배은빈,조원탁,허중보 大韓齒科補綴學會 2022 대한치과보철학회지 Vol.60 No.1
Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic detachment. Recently, one-piece type mini-implant with additional retentive structure has been introduced to increase the retention and stability of the mini-implant. The mini-implant is based on spreading the upper retentive structure with a spreader and connected it with the inner surface of the zirconia prosthesis. In two cases, we tried to reduce these complications through the mini-implant on the narrow mandibular anterior region, and it was possible to reduce the overall treatment period through a digital system. In this case report, restoration using the digital mini-implant system showed improvement of patient satisfaction on the aspect of function and esthetic in the narrow mandibular anterior region. 하악 전치부와 같이 골 폭이 좁은 환자에서 미니 임플란트 사용은 기존의 직경 임플란트의 대안으로 보고된다. 그러나, 기존 일체형 미니 임플란트의 사용시 보철물 탈락과 시멘트 사용으로 인한 임플란트 주위염과 같은 합병증의 발생이 보고되고 있다. 최근 미니 임플란트의 유지력 및 안정성을 높이기 위해 상부에 부가적인 유지구조를 가진 일체형 미니 임플란트가 소개되었다. 상부 탄성부를 스프레더로 벌려 줌으로써 지르코니아 보철물 내면의 결합구조와 결합하는 방식을 기반으로 한다. 이에 본 증례는 좁은 폭경의 하악 전치부에서 상부에 결합구조를 가진 일체형 미니 임플란트를 통하여 이러한 합병증을 줄이고자 하였으며 디지털 시스템을 이용하여 전반적인 치료기간을 단축하였다. 두명의 환자에서 유지기능과 심미적인 면에서 만족스러운 임상결과를 얻었기에 본 증례를 보고하고자 한다.
임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구
송은주 ( Eun Ju Song ),배은빈 ( Eun Bin Bae ),최재원 ( Jae Won Choi ),배지현 ( Ji Hyeon Bae ),김지영 ( Ji Young Kim ),이소현 ( So Hyoun Lee ) 한국치위생과학회 2016 치위생과학회지 Vol.16 No.1
The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.
최재원,김소연,배지현,배은빈,허중보 대한치과보철학회 2017 The Journal of Advanced Prosthodontics Vol.9 No.4
PURPOSE. The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS. Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni’s correction (α=0.05/3=0.017). RESULTS. A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION. Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.