RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        랫드에서 amitraz의 출생 전후 발생 시험

        김성환,임정현,박나형,문창종,박수현,강성수,배춘식,김성호,신동호,김종춘,Kim, Sung-Hwan,Lim, Jeong-Hyeon,Park, Na-Hyeong,Moon, Changjong,Park, Soo-Hyun,Kang, Seong-Soo,Bae, Chun-Sik,Kim, Sung-Ho,Shin, Dong-Ho,Kim, Jong-Choon 대한수의학회 2010 大韓獸醫學會誌 Vol.50 No.2

        This study investigated the potential effects of amitraz on the pre- and postnatal development, behavior, and reproductive performance of offspring of parent rats given amitraz during pre-mating, gestation, and lactation. The test chemical was administered via the drinking water containing 0, 40, 120, and 360 ppm to male rats from 2 weeks before mating to the end of 14-day mating period and to females from 2 weeks before mating, throughout mating, gestation and lactation up to weaning. Based on fluid consumption, the male rats received an average of $0,\;5.7{\pm}1.33,\;13.2{\pm}2.08,$ and $35.8{\pm}3.42$ mg/kg/day amitraz, and the female rats received an average of $0,8.7{\pm}4.42,\;20.1{\pm}9.60,\;and\;47.6{\pm}22.38$ mg/kg/day amitraz, respectively. At 360 ppm, an increase in the incidence of abnormal clinical signs, a suppression in the body weight gain, a decrease in the food consumption and litter size, an increase in the post-implantation loss, and a decrease in the seminal vesicle weight were observed in the parent animals. In addition, a suppression in the body weight gain, a decrease in the grip strength, a delay in the negative geotaxis, an increase in the pre- and post-implantation loss, and a decrease in the number of live embryos were observed in the offspring. At 120 ppm, suppressed body weight gain and reduced food consumption were observed in the parent rats. Suppressed body weight gain and decreased grip strength were also observed in the offspring. There were no signs of either reproductive or developmental toxicity at 40 ppm. Under these experimental conditions, the no-observed-adverse-effect level of amitraz for parent rats and their offspring was estimated to be 40 ppm in rats.

      • SCOPUSKCI등재

        SrCl<sub>2</sub>:Eu<sup>2+</sup>,Na<sup>+</sup> X-선 영상저장 형광체의 발광특성

        김성환,김완,강희동,도시홍,서효진,김영국,김도성,Kim, Sung-Hwan,Kim, Wan,Kang, Hee-Dong,Doh, Sih-Hong,Seo, Hyo-Jin,Kim, Young-Kook,Kim, Do-Sung 한국재료학회 2003 한국재료학회지 Vol.13 No.6

        Photoluminescence(PL), photostimulated luminescence(PSL) and thermoluminescence(TL) in $SrC1_2$:$Eu^{2+}$ , $Na^{+}$ phosphor powder were measured, and the activation energies(trap depth) of traps associated with TL and PSL were investigated. The PL and PSL in the studied sample is due to the $4f^{6}$ 5d\longrightarrow$4f^{7}$transition of $Eu^{ 2+}$. TL glow curve is single peak, and its peak temperature is about 377.2 K. The PL, PSL and TL emission spectra of the phosphors are located in the range of 380∼440 nm, peaking at 408 nm. The activation energy of the PSL trapping center is 0.78 eV and that of the TL trapping center is 0.79 eV. We, thus, suggest that the trapping centers giving rise to the PSL are identical to those giving rise to the TL.

      • KCI등재

        마이크로웨이브 조사를 이용한 반도체성 단일벽 탄소나노튜브의 선택적 분리

        김성환,송우석,김유석,김수연,박종윤,Kim, Sung-Hwan,Song, Woo-Seok,Kim, Yoo-Seok,Kim, Soo-Youn,Park, Chong-Yun 한국진공학회 2011 Applied Science and Convergence Technology Vol.20 No.4

        본 연구에서는 열화학기상증착법과 나노구조의 Fe/$Al_2O_3$/Si 촉매층을 이용하여 단일벽 탄소나노튜브를 합성하고 마이크로웨이브 조사를 통해 금속성 단일벽 탄소나노튜브를 선택적으로 제거하고 반도체성 단일벽 탄소나노튜브를 분리하였다. 조사시간의 변화에 따른 단일벽 탄소나노튜브의 전기적, 구조적 특성을 분석한 결과, 조사시간이 120초인 경우, 금속성의 단일벽 탄소나노튜브가 선택적으로 제거되어 약 95%의 반도체성 단일벽 탄소나노튜브를 분리할 수 있었으며, 뿐만 아니라 남아있는 반도체성 단일벽 탄소나노튜브가 손상 없이 우수한 결정성을 지니는 것을 확인할 수 있었다. 이러한 방법은 반도체성 단일벽 탄소 나노튜브를 기반으로 한 전계효과 트랜지스터 및 다양한 나노전자소자의 응용에 유용한 정보를 제공하리라 기대한다. In this study, single-walled carbon nanotubes (SWCNTs) were synthesized on a Fe/$Al_2O_3$/Si layer by thermal chemical vapor deposition. Metallic SWCNTs were selectively removed by microwave irradiation. Electrical and structural characterizations of the SWCNTs clearly revealed that the metallic SWCNTs were almost removed by microwave irradiation for 120 sec. The remained semiconducting SWCNTs with a high crystalline structure were obtained over 95%. This method would provide useful information for applications to SWCNTs-based field effect transistors and multifaceted nanoelectronics.

      • The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT

        김성환,남기표,류재광,윤순상,Kim, Sung-Hwan,Nam, Ki-Pyo,Ryu, Jae-Kwang,Yoon, Soon-Sang The Korean Society of Nuclear Medicine Technology 2012 핵의학 기술 Vol.16 No.1

        심근관류 SPECT의 영상획득 방법에는 Body contour와 Circular 방식이 있고, 환자와 검출기 사이의 거리를 줄이기 위해 Body contour 방식을 주로 사용한다. 그러나 이중(Dual) 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우에는 환자와 검출기 사이의 거리가 Body contour 방식이 Circular 방식에 비해 더 증가하는 경향이 있다. 본 연구의 목적은 이중 검출기 장비에서 수직방식으로 검출기를 설정하여 영상을 획득하는 경우, Body contour 방식과 Circular 방식에서 환자와 검출기 사이의 거리를 비교하고, 거리에 따라 영상에 미치는 영향을 파악하여 영상의 질을 높이기 위한 방안을 제시하고자 시행하였다. 실험에 사용된 장비는 GE INFINIA Gamma Camera와 Anthropomorphic torso 모형에 심장 모형을 삽입하여 영상을 획득하였고, 2011년 8월 본원에서 심근관류 SPECT를 시행한 환자 40명을 대상으로 하였다. 모형 제작은 실제 환자조건과 동일하게 하기 위하여 심근에 74 kBq (0.22 mCi)/cc, 폐에 2.59 kBq ($60{\mu}Ci$)/cc, 연부조직에 11.1 kBq (2.2 mCi)/cc의 201-Tl을 주입하여 제작하였고, 영상획득 조건은 회전각 $6^{\circ}$, 50 sec/frame으로 환자와 동일한 조건으로 하였다. 영상획득 방식에 따른 차이를 확인하기 위해 Body contour와 Circular 방식으로 영상을 획득하여 환자와 검출기 사이의 거리를 각각 측정하여 비교하였고, 정상군과 비 정상군의 영상을 육안 분석하였다. 거리에 따라 영상에 미치는 영향을 확인하기 위해, 모형 실험에서 Circular 방식으로 회전반경을 18.8, 21.8, 23.8, 25.8, 28.8 cm 로 다르게 설정하여 영상을 획득하였고, 각 영상에서 심첨(Apex)에 관심영역을 설정하여 반치폭을 비교하였다. 모형 실험 결과, Body contour를 이용한 실험에서 산출된 반치폭은 6.23 mm이고, Circular mode에서 18.8, 21.8, 23.8, 25.8, 28.8 cm의 회전반경으로 산출된 반치폭은 각각 5.41, 6.24, 6.33, 6.42, 6.93 mm이다. 환자 데이터에서 Body contour의 회전반경이 -3.5 cm ~ 9.5 cm으로 차이를 보였고, Circular mode에 비해 평균 2.5 cm 더 큰 차이를 보였다. 본 연구를 통해, INFINIA 장비에서 Circular mode가 Body contour를 사용한 영상 획득 방법보다 낮은 반치폭을 보였다. 비록 INFINIA장비의 두 가지 영상 획득 방식에 대한 비교였지만, INFINIA장비를 이용한 심근관류 검사에서는 Circular mode 의 영상 획득 방식이 더 적합하다고 사료된다. Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

      • KCI등재

        염화알칼리토금속 화합물에 도핑된 $Eu^{2+}$ 이온의 광발광 및 광자극발광특성

        김성환,김선칠,Kim, Sung-Hwan,Kim, Sun-Chil 대한방사선기술학회 2006 방사선기술과학 Vol.29 No.3

        염화알칼리토금속화합물에 Eu 이온을 첨가하여 $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba) 형광체를 제조하고, 제조된 형광체의 광발광(photoluminescene) 및 광자극발광(photostimulated luminescence ; PSL) 특성을 조사하였다. $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba)형광체의 광발광 및 광자극발광 파장은 주 모체의 양이온의 종류에 따라 조금씩 이동하였다. $CaCl_2:Eu^{2+}$ 형광체의 최적 제조조건은 $Eu^{2+}$ 이온의 농도가 0.5 mol%, 소결온도와 시간은 각각 $745^{\circ}C$, 45분이었으며, 이때 발광파장범위는 $365{\sim}388\;nm$, 피이크파장은 370 및 380 nm이었다. $BaCl_2:Eu^{2+}$ 형광체의 최적 제조조건은 $Eu^{2+}$ 이온의 농도가 0.5 mol%, 소결온도와 시간은 각각 $905^{\circ}C$, 45분이었으며, 이때 발광파장범위는 $370{\sim}460\;nm$, 피이크파장은 398 nm이었다. $SrCl_2:Eu^{2+}$ 형광체의 최적조건은 $Eu^{2+}$ 이온의 농도가 0.5 mol%, 소결온도와 시간은 각각 $840^{\circ}C$, 45분이었으며, 발광파장영역은 $380{\sim}440\;nm$, 피이크파장은 407 nm이었다. $MCl_2:Eu^{2+}$(0.5 mol%)(M = Ba, Sr) 형광체는 약 $0.25{\sim}200\;mGy$까지 선량 범위에서 선형성을 나타내었으며, 상온에서 $SrCl_2:Eu^{2+}$ (0.5 mol%) 및 $BaCl_2:Eu^{2+}$ (0.5mol%) 형광체의 광자극발광 강도는 상온에서 120분간 각각 60%, 40% 감쇠하였다. In this study, $Eu^{2+}$ ion was used as an activator in order to enhance the PL(photoluminescene) and PSL(photostimulated luminescence) intensity of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba)phosphors and the chracteristics of PL and PSL of the phosphors were investigated. The emission of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba) phosphors shows a shift wavelength when the host caution changes. The optimal preparing conditions of $CaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $745^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $CaCl_2:Eu^{2+}$ locate in the range of $365{\sim}388\;nm$, peaking at 370 and 380 nm. The optimal preparing conditions of $BaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $905^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $BaCl_2:Eu^{2+}$ locate in the range of $370{\sim}460\;nm$, peaking at 398 nm. The optimal preparing conditions of $SrCl_2:Eu^{2+}$ phosphor were 0.5mol% of $EuCl_2$ and the sintering temperature were $840^{\circ}C$, 45min. in $H_2$ atmosphere. The PL and PSL spectra of $SrCl_2:Eu^{2+}$ locate in the range of $380{\sim}440\;nm$, peaking at 407 nm. The dose response of the $MCl_2:Eu^{2+}$(0.5 mol%)(M = Ba, Sr) phosphors were linear within $0.25{\sim}200\;mGy$ of 100 kV X-ray and the PSL intensity of the $SrCl_2:Eu^{2+}$ and $BaCl_2:Eu^{2+}$ phosphors faded to approximately 60 and 40% respectively after 120 min at room temperature.

      • 초대석-한원곤 강북삼성병원장

        김성환,Kim, Seong-Hwan 대한병원협회 2007 대한병원협회지 Vol.36 No.4

        "제가 의사가 된것은 아버님이 원해서가 아니라 바로 제자신이 하고 싶었기 때문이지요. 바로 아버님처럼 외과의사가 되고 싶어서 의과대학에 갔고 의사가 된 것입니다" 한원곤 원장에게 있어서 비인기과로 전락했다는 것은 아무런 문제가 되지 못한다. 본인이 그렇게 원해서 된 외과의사이기 때문이다

      • KCI등재

        모델기준적응제어 및 직접토크제어 시스템을 이용한 유도전동기의 센서리스 속도제어

        김성환,정범동,윤두오,이성근,오세진,Kim, Sung-Hwan,Jeong, Bum-Dong,Yoon, Doo-O,Lee, Sung-Gun,Oh, Sae-Gin 한국정보통신학회 2012 한국정보통신학회논문지 Vol.16 No.12

        본 논문은 모델기준적응제어 및 직접토크제어 방식을 이용한 새로운 유도전동기의 센서리스 속도제어 방법을 제안한다. 모델기준적응제어는 기준모델과 조정모델을 설정하고 이들의 출력을 비교하여 조정모델 및 제어를 위한 속도 추정값을 얻는 제어법이다. 그리고 직접토크제어는 토크와 자속을 독립적으로 제어하는 방법으로 토크, 자속 지령치와 전동기 고정자 전압, 전류 값을 이용해 추정한 토크, 자속을 비교하여 히스테리시스 밴드를 거쳐 그 오차를 가장 최소화하기 위한 전압벡터를 선정하여 출력하는 방법이다. 본 논문에서는 제안한 방식의 이론적인 배경 및 타당성에 대해 기술하였으며 모의실험을 통해 제안된 방식의 우수성을 검증하였다. This paper proposes a new sensorless speed control scheme of induction motor using Model Reference Adaptive Control and Direct Torque Control System. The Model Reference Adaptive Control System is based on the comparison between the outputs of Reference Model and Adjustable Model. The error between the estimated quantities obtained by the two models is used to drive a suitable adaptation mechanism which generates the estimated rotor speed for the Adjustable Model. And the Direct Torque Control scheme controls torque and flux by restricting the flux and torque errors within respective hysteresis bands, and motor torque and flux are controlled by the stator voltage space vector using optimum inverter switching table. The simulation results of proposed method indicate good speed responses from the low speed range to the high, and also show favorable characteristics of load operation.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼