http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
유비쿼터스 정보화사업 평가모형 및 지표 개발에 관한 연구
김기호,김재전,이상준,Kim, Ki-Ho,Kim, Jae-Jon,Lee, Sang-Joon 한국디지털정책학회 2008 디지털융복합연구 Vol.6 No.3
This research aims at developing and distributing models and indexes that can evaluate ubiquitous information projects in order to enhance the objectivity and validity of their evaluation. The research adopts a BSC(Balanced Score Card) concept with four views, economic, policy, social, and technical views. The research induces a model of pre-evaluation and a model of post-evaluation according to each view. In order to secure the validity of the models, they are revised and complemented by obtaining advice through interviews with five experts in related fields, and the validity and application possibility of the indexes are verified by surveying ten people working in those fields. Finally, investigating their weights according to the importance of each view and index, they are evaluated using an AHP (Analytic Hierarchy Process) method.
한국인에서 다발성 내분비선종 증후군의 초기 증상 및 임상 양상
김기호,구민영,허성모,이세경,최준호,이정언,김지수,정재훈<SUP>1<.SUP>,남석진,양정현,김정한,Ki-Ho Kim,M.D.,Min-Young Koo,M.D.,Sung-Mo Hur,M.D.,Se-Kyung Lee,M.D.,Jun-Ho Choe,M.D.,Jeong Eon Lee,M.D.,Jee Soo Kim,M.D.,Jae-Hoon Chung,M.D.<SU 대한갑상선-내분비외과학회 2010 The Koreran journal of Endocrine Surgery Vol.10 No.4
Purpose: Multiple endocrine neoplasia (MEN) syndrome is an inherited, autosomal dominant disease that presents as a combination of several endocrine tumors. Early diagnosis of this syndrome is difficult, because of the nonspecific symptoms and signs. This study analyzed early manifestations and clinical characteristics in patients with MEN syndrome. Methods: Medical records were retrospectively reviewed and telephone interviews were conducted with 35 patients diagnosed as MEN syndrome at Samsung Medical Center from December 1994 to December 2009. Results: The 35 patients had been diagnosed as MEN1 (n=14), MEN2A (n=19) and MEN2B (n=2). The early manifestations of the 14 MEN1 patients were related with hyperparathyroidism (n=5), pituitary tumor (n=3), and pancreatic endocrine tumor (n=2). There were tumors of the parathyroid gland in all 14 patients, anterior pituitary in eight patients, and pancreatic islet cells in seven patients. Four cases were incidentally detected during the screening examination. Six cases harbored a MEN1 gene mutation. The twenty-one patients diagnosed with MEN2 comprised medullary thyroid cancer (n=20), adrenal pheochromocytoma (n=15), and hyperparathyroidism (n=4). The MTC-related symptoms in the 21 MEN2 patients included neck mass or discomfort in 12 patients and pheochromocytoma-related symptoms in seven patients. Two cases were detected through familial genetic screening test. The RET gene mutationwas detected in 19 cases. Conclusion: Early manifestations of MEN syndrome were very different between the types of MEN and the types of its presenting tumor. The early diagnosis and proper management of MEN requires awareness of the clinical characteristics of each expressed tumor and is influenced by genetic screening methods. (Korean J Endocrine Surg 2010; 10:266-275)
글로우 방전을 이용한 고효율 공기 정화용 화학 반응기의 특성관찰에 관한 연구
김기호,부민호,이상천,Kim, Gi-Ho,Bu, Min-Ho,Lee, Sang-Cheon 대한화학회 2006 대한화학회지 Vol.50 No.1
방전을 이용한 화학반응기의 기본 모델은 관통형 속 빈 음극 방전셀을 응용하였다. 최근 글로우 방전은 원자분광학에 있어서 방출원으로서의 역할과 더불어 원자화 장치로서 점차적으로 그 연구의 범위를 넓혀가고 있으며, 미량분석, 철강분석, 표면 분석 등에 널리 사용되고 있으며 타 분석 기기와의 접목 등을 통하여 상당한 기술적 성과가 이루어지고 있다.1 또한 본 연구 이전에 기초적인 글로우방전의 성질과 방출 특성에 대해서도 여러 차례 재검토된 바 있어 본 실험에 활용할 수 있었다.2-3 지난 1993년에는 저온의 플라즈마를 이용하여 대기중의 유독가스의 처리에 대한 연구가 발표되었으며, 이 논문에 의하면 연속적인 공기의 흐름 하에서 직류 글로우 방전을 이용하면 유해성 가스인 SO2와 NO의 제거가 가능하다고 보고되었다.4 이를 바탕으로 본 연구에서는 안정적인 공기 플라즈마의 형성과 관통형 양, 음극관 안으로 모든 흐름공기가 음 글로우(Negative glow)영역을 통과하도록 고효율 반응기를 설계하였다. 현재 본 연구에서 디자인한 속 빈 음극관 형 글로우 방전은 경제성이 우수하며 사용하기 쉽다는 것 외에도 방출원 으로서의 장점도 제공함을 관찰하였다. the basic model of chemical reactor using glow discharge, we used cathode discharge cell with vacant cavity in the middle. Currently glow discharge is widely studied as a radiation source or atomization device in atomic spectroscopy and remarkable technological achievements are made through the graft with other analysis devices such as microanalysis and steel analysis.1 Additionally, as the characteristics of basic glow discharge and radiation have been reviewed many times, those results could be used in this experiment.2-3 In 1993, an article regarding the treatment of poisonous gas in the air using low temperature plasma was published. According to this article, if DC Glow Discharge is used under continuous atmospheric flow, poisonous gases such as SO2 and NO can be removed.4 Based on those findings, we designed highly efficient reactor where stable air plasma is composed and all air flow pass the negative glow area passing through the tube. It was observed that the cathode tube type glow discharge developed in this study would be economical, easy to use and could be used as radiation source as well.