RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 서울의 Penicillinase Producing Neisseria gonorrhoeae 발생빈도(1998)

        김재홍,김준호,반재용,이정우,황성주,정준규,정성태,강진문,조흔정,홍창의,정혜신,이한승,김이선,이봉길,이종호,선영우,한기덕,윤성필,이성훈,안종성,박석범,문승현,조항래,김형섭,류지호,황재영,박준홍,손상욱 한양대학교 의과대학 2001 한양의대 학술지 Vol.21 No.1

        In recent years, gonorrhea has been pandemic and remains one of the most common STDs in the world, especially in developing countries. For the detection of a more effective therapeutic regimen and assessing the prevalence of Penicillinase Producing Neisseria gonorrhoeae(PPNG), we have been trying to study the patients who have visited the Venereal Disease Clinic of Choong-Ku Public Health Center in Seoul since 1980 by menas of the chromogenic cephalosporin method. In 1998, 93 strians of N. genorrhoeae were isolated, among which 60(64.5%) were PPNG. The prevalence of PPNG in Seoul, which had been decreased to 39% in 1996 after a peak of 74.3% in 1993, is increased to 64.5% in 1998.

      • SD Rats를 이용 1-hexene의 흡입독성 연구

        김현영,임철홍,정용현,이권섭,이성배,이준연,한정희,전윤석,이용묵 한국환경독성학회 2001 환경독성보건학회지 Vol.16 No.4

        The purpose of this study was to investigate the acute (4 hours) and repeated-dose (6 hours a day, 5 days a week, 4 weeks) toxic effects of I -hexene on Sprague- Dawley (SD) rats which were treated by inhalation. The results were as follows; I. The median lethal concentration (LC_(50)) was estimated 52,694 ppm (confidence limit 95%; 49,494~55,447 ppm) in acute inhalation. Abnormal clinical signs related to the l-Hexene were not observed with the acute inhalation dose. Gross findings of necropsy revealed on evidence of specific toxicity related to the 1-hexene, II. By repeated inhalation exposure the body weight of male were more or less reduced by the dose of 2,500 ppm and 5,000 ppm compared with control group. However there were no significant variation hematology and blood biochemistry for the exposed rats compared with the control rats. Abnormal clinical signs and gross findings of necropsy related to the 1-hexene were not shown. In conclusion when we exposed I-hexene to SD rats for 4 weeks, 5 days per week, 6 hours per day, the Lowest observed effect level (LOEL) was over 2,500 ppm and Non observed effect level (NOEL) was below 500 ppm.

      • 자동차용 실리콘 가속도센서의 개발(Ⅱ)

        이종현,신장규,이상룡,천희곤,조찬섭,심준환,류인식,박석홍,허정준,박기열 경북대학교 센서기술연구소 1994 연차보고서 Vol.1994 No.-

        자동차의 air-bag 장치에 실용될 수 있는 압저항형 단결정 실리콘 가속도센서 칩을 개발하기 위하여 결정 실리콘 미세구조의 제조방법을 확립하고, 단위공정의 검증을 통하여 일괄공정에 의한 PROTO-TYPE 칩을 만드는 기술을 연구하였다. 단결정 실리콘 미세구조는 선택확산법을 이용하여 정확히 선택된 영역에만 air-gap을 형성하여 미세구조의 측면식각을 방지하는 선택확산법에 의한 실리콘 마이크로머시닝 기술로 제조하였다. 일괄공정을 위한 단위공정확립을 위하여 PROTY-TYPE 8빔 브릿지형 가속도 센서를 제조하였다. 제조된 칩의 가속도에 따른 출력전압은 선형성을 나타내고 있으며, 감도는 약 50 ㎶/V·g로 나타났다. 이 감도는 50G용 가속도센서의 사양을 만족하지 못했다. 이는 공정에 의한 문제라기 보다는 가속도센서의 시뮬레이션에 의해 설계한 구조가 이미 원하는 감도에 못 미친다는 것으로 생각된다. 따라서 2차 공정으로 제조될 가속도센서의 파라미터를 SuperSAP 유한요소 패키지를 이용하여 실리콘 미세구조부의 파라미터에 따른 특성을 시뮬레이션하였다. 설계된 50G용 가속도센서의 mass Pad의 반경 및 빔 길이, 빔 폭, 빔 두께, 그리고 mass의 각 파라미터 값은 700 ㎛, 120 ㎛, 5 ㎛, 1.0 ㎎ 이었다. 반도체 공정기술, 관성질량 제조법 및 선택확산을 이용한 마이크로머시닝을 사용하여 일괄공정으로 8빔 브린지형 가속도센서를 제조하였다. We researched the establishment of the silicon microstructure fabrication technique to develop a piezoresistive type silicon acceleration sensor chip and the technique to make a proto-type chip by the verification of the unit-process. Silicon microstructure is fabricated silicon micro-machining by selective diffusion method. This method prevent a side-etching of microstructure because selective diffused region is only formed an air-gap. We fabricated a proto-type 8-beam bridge-type acceleration sensor to establish the unit-process for the batch-process. The output voltage of the chip represented linearity with acceleration, and the sensitivity was about 50 ㎶/V·g. But this sensitivity dosen't satisfy the requirements of a practical acceleration sensor. The cause of this result is assumed not process problem, but the structure designed by simulation isn't suitable already. Threfore, the characteristics of parameters of the acceleration sensor that will be fabricated by 2nd-process is simulated by SuperSAP finite-element package. The determined parameter values of beam length, beam width, beam thickness, mass, and mass radius are 120 ㎛, 5 ㎛, 1.0 ㎎, and 700 ㎛, respectively. We fabricated 8-beam bridge-type acceleration sensor by batch-process using a semiconductor process technique, proof-mass fabrication method, and micromachinig using selective diffusion.

      • 마이크로 컴퓨터를 이용한 다종의 전동기 속도제어 장치의 설계

        李俊煥,宋祥燮,咸雲哲 全北大學校 1983 論文集 Vol.25 No.-

        In this paper, we show that synchronous and dc motor speed controllers are designed with PLL based frequency synthesizer method. In addition, microcomputer based stepper motor speed controller is also designed. All these controllers are connected to SRC-80 microcomputer to input the speed command through hex-key button.

      • KCI등재

        흉골 골절의 의의에 관한 임상적 연구

        원형섭,황성연,박정배,이준형,박철완,이근 대한응급의학회 1996 대한응급의학회지 Vol.7 No.2

        It has been known that sternal fracture increases the risk of potentially life-threatening injuries, such as myocardial, pulmonary, and thoracic vascular injuries, and it has 25% to 45% of mortality, primarily resulting from these underlying injuries. The authors reviewed retrospectively the medical records and radiographic findings of the patients who admitted with sternal fracture at Chung Ang Gil Hospital from 1 June 1994 to 31 December 1995 to evaluate the significance and clinical course of sternal fracture. The results were followings: 1. The male to female ratio was 3:2 and the mean age was 43.1 and 45.4 years old in male and female, respectively. 2. Motor vehicle occupant accident was the most common cause of sternal fracture. 3. Of 33 cases, there was no death, but common associated injuries which were rib fracture, hemothorax, lung contusion, vertebral fracture, penumothorax, long bone fracture, myocardial contusion, flail chest, facial chest, facial bone fracture, and pericardial effusion, in order. 4. The clinical course of sternal fracture was determined primarily by associated injuries except for communited sternal fracture. 5. The patients with isolated sternal fracture, who had an otherwise normal chest x-ray, normal electrocardiogram, no other significant associated injuries and are hemodynamically stable, had a benign clinical course.

      • FOPS(Film on Porous Silicon)를 이용한 ZnO 에어브리지의 제작

        허정준,류인식,심준환,조찬섭,이종현 경북대학교 센서기술연구소 1994 센서技術學術大會論文集 Vol.5 No.1

        Micromachining technique by FOPS(Film on Porous Silicon) method using ZnO thin film was studied to fabricate ZnO air-bridge type microstructures. Porous silicon was formed selectively in n^(+)-diffused region of (100) oriented silicon substrate by anodic reaction in 20 wt% HF solution. ZnO thin film was deposited on the porous silicon layer by RF magnetron sputtering and then pattern was defined by standard photolithography. Finally, porous silicon was etched away in 5 wt% NaOH solution. The fabricated ZnO microstructures have 20μm width, 40μm thickness and microstructure was cleanly formed on the cavity. Also, microstructure of arbitrary shape was fabricated.

      • Flow 센서응용을 위한 SOI bridge resistor의 제조

        심준환,조찬섭,이종현 경북대학교 센서기술연구소 1991 센서技術學術大會論文集 Vol.2 No.1

        Porous silicon layer (PSL) was fabricated by anodic reaction of n^(+) layer of n^(+)/n silicon structures, The dependence of HF concentration, applied bias and reaction time on the porosity of PSL were investigated. FIPOS-SOI bridge resistors were achieved for the application to flow sensors using n/n^(+)/n silicon structures, Those resistors are thermally isolated by oxidized porous silicon. The SOI bridge was 50μm wide, 900 μm long, and 5μm thick, Measured TCR(temperature coefficient of resistance) was 1.1x10^(-3)/℃.

      • 흰쥐에서 음경발기 평가의 척도로서 음경해면체내압측정술 확립

        송윤섭,김용준,이광우,김준모,문기혁,박영호,민영기,유형균,김형건 순천향의학연구소 2001 Journal of Soonchunhyang Medical Science Vol.7 No.1

        Purpose: Because studies about the control of penile erection at the entral nervous system was dependent on the animal experiments, establishment of measuring penile erection is important to evaluate the effects changes at the central nervous system on the penile erection. Intracavernous pressure measurement in rats has been introduced as a suitable index for the evaluation of penile erection but this method is invasive and technically difficult. So, we established the intracavernous pressure measurement in rats as the experimental index for penile erection. Materials and Methods: 42 male adult Sprague-Dawley rats (250-300gm) were divided to saline or papaverine treated group. Rats were placed on a heating table to maintain their body temparature and anesthetized with 50mg/kg of pentobarbital sodium by intraperitoneal injection. A cannula was inserted to the left carotid artery to measure systemic blood pressure. Saline (0.05, 0.1ml), papaverine(0.05, 0.1, 0.25, 0.5, 1.0, 2.0mg) were injected intracavernously via 26 guage needle filled with saline or papaverine which connected to pressure transducer and polygraph was inserted into the corpus cavernosum on one side to inject the drug and to measure intracavernous presure. Results: Properly executed insertion and intracavernous administration produced a instantaneous but transient rise in intracavernous pressure that substantially stabilized and maintained at 5.4±0.4mmHg. Intracavernous pressure and duration of penile blood flow following intracavernous injection of papaverine are increased comared to those of saline. Conclusions: Monitoring intracavernous pressure in rats represents a suitable index for the evaluation of penile erection in small laboratory animals.

      • 암모니아 공정에서 CO₂ 고정의 최적화

        서성규,이정섭,송준석 國立麗水大學校 環境問題硏究所 2004 環境硏究論文集 Vol.6 No.-

        This study was investigated the effects of various system parameters on the absorption of carbon dioxide into absorption solution. An aqueous potassium carbonate solution was used as a chemical absorbent in order to figure out the effect of chemical reaction. For this purpose, the chemical analysis of potassium carbonate solution was performed. The changes of pressure, temperature, K₂CO₃solution flow/feed gas ratio and solution concentration in the absorber and the changes of pressure and temperature in the stripper were also analyzed. The analysis result shows that K₂CO₃ concentration in potassium carbonate solution was 99.6%. The optimum pressure was found to be 27.0㎏/㎠ and the optimum temperature was to be 68℃, the optimum concentration of potassium carbonate solution was to be 26.0wt% in the absorber. The CO₂ leakage decreased with the increment of the K₂CO₃ solution flow/feed gas ratio. But the H₂ leakage in the CO₂ product increased at or above the K₂CO₃ solution flow/feed gas ratio of 1.10. This H₂ leakage induced by the loss of ammonia production. The effects of the changes of the operation condition of the CO₂ stripper to the K₂CO₃ conversion are as follows. The K₂CO₃ conversion decreased as the pressure decreased. The K₂CO₃ conversion increased as the temperature increased. However, increasing the temperature without decreasing the pressure did not bring positive effect. The optimum pressure was found to be 0.45㎏/㎠.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼