방전 플라스마에 의한 CFC-12(CCl2F2)의 분해
황명환,우인성,조정국,강현춘,안형환,이한섭,강안수 한국산업안전학회 1999 한국안전학회지 Vol.14 No.3
Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocarbon) were investigated by SPCY(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5∼50㎑). flow rates (100∼1,000mL/min), initial concentrations(100∼1,000ppm), electrode materials(W, Cu. Al), electrode thickness(1, 2, 3mm) and reference gases(N₂, O₂, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W, respectively, and that decomposition efficiency decreased with increasing frequency above 20㎑ and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3mm. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al).
코로나 대전된 복합절연재료의 표면상태가 전위감소에 미치는 영향
황명환,정재희,조한구,송진호,이덕출 한국산업안전학회 1997 한국안전학회지 Vol.12 No.2
Especially, Fiber glass Reinforced Plastics(FRP) is the best composite insulating material which has been so far. Therefore, it's worthy of notice to investigate on the corona electrified composite insulating material by surface condition. And then some other materials will be focussed on. In this study, charge decay were measured with charging-time and grid voltage on FRP composite material surface in order to analyze the mechanism. As a result we have studied that the way of the composite glass fiber(GF) and Polymer and the condition of the contaminated surface was different. In case of the GF is mixed with vertical, charge decay speed is fast because the charge is easily leaked. On the other hand, the surface charge decay speed is depend on conductive or insulated of the contaminant.
진동형 분진 최소착화에너지측정장치에서 분진 응집현상이 미치는 영향
정재희,최충석,목연수,최광석,황명환,우인성,Yamaguma, M.,Kodama, T.,Cheung, W.L. 한국산업안전학회 1999 한국안전학회지 Vol.14 No.3
It is widely recognized that Hartmann tube for measuring the minimum ignition energy(MIE) of powder. But It requires long time and operational skills for measuring. As a variety of new fine powders are being produced day by day in industry, Japen has been developing a measurement system which employs a new method to create a dust/air mixture in a miniature combustion box. In this system, by vibration, the powder is successively fed downward through a hopper made up of metal mesh, and then it is formed into a thin, certain-like, dust/air mixture. With this new apparatus, three types of powder-Lycopodium, Anthraquinone, and Polyacrylonitrile-were tested and the data of MIE were compared with those of a conventional apparatus (the Hartmann tube). Two of them agreed satisfactory, but the other, Anthraquinone, showed quite different values. It is guessed that the agglomerations of the powder particles appear because of particle shapes, static-charge and humidity.
확률론적 안전성평가를 위한 일반 기기 신뢰도 데이타 베이스 구축 절차와 적용
김길유,김태운,정원대,황미정,임태진 한국산업안전학회 1997 한국안전학회지 Vol.12 No.4
건설중이거나 기기 이력이 부족한 원자력 발전소에 대한 확률론적 안전성평가에 사용되는 일반 기기 신뢰도 데이타를 기 개발된 일반 데이타 및 발전소 데이타를 취합하여 구한다. 이를 위해 본 논문에서 사용한 계산 Code는 모수적 선험적 베이지안 방떱에 근거하여 3단계 베이지안 방법으로 한국원자력연구소에서 개발한 MPRDP Code이다. 일반 자교원에서 주로 자료를 취합하였으므로 각 문헌들 사이에 존재할 수 있는 종속성을 고려하여 Code에서 처리하였다. 본 논문에서는 결과로 얻어진 기기 신뢰도 자료표의 일부분을 보여준다. This paper presents the development procedure and application of the generic component reliability data base considering the dependency among dependent generic compendia in NPPs (Nuclear Power Plants) PSA (Probabilistic Safety Assessment) under construction or without operating history. We use MPRDP (Multi-Purpose Reliability Data Processor) code developed in KAERI (Korea Atomic Energy Research Institute) based on a PEB (Parametric Empirical Bayesian) procedure to estimate the reliability. The employed model in this study accounts for the relative credibility as well as the dependency among generic estimates. Numerical examples and the part of summarized reliability data table are provided as the application.
이영희,YAMAGUMA,M .,목연수,황명환,우인성,조정국 한국산업안전학회 1999 한국안전학회지 Vol.14 No.3
In this paper, characteristics of ozone generation by using coil and SPCP+DC corona reactor was studied. The ceramic-based surface discharge electrode, which was first invented as a high-efficiency ozonizer, has been used as an experimental plasma chemical reactor.(Surface Induced Plasma Chemical Processing, SPCP.) The electrode, however, has a structural disadvantage that a highly energetic plasma region is localized near the electrode surface, which may make it impossible for higher efficiency to realize. In an attempt to overcome this advantage, we have developed a hybrid reactor which employs a corona discharge unit together with the surface discharge unit. Experimental results suggest that the efficiency of the ozone production rate is improved when positive corona discharge is added.
김완식,박동호,황영희,김흥대,안기량,석민호,김지영,장경덕,서병태 대한마취과학회 1982 Korean Journal of Anesthesiology Vol.15 No.1
Midazolam maleate, a water soluble banzodiazepine unlike diazepam, was synthetized by Walser and Fryer in 1975. In order to ealuate the effectiveness as an induction agent for general anesthesia, 22 elective surgical patients belonging to ASA classification 1 and 2 were selected. And ten patients (male 7, female 3, average 33.5 years old) were induced with midazolam maleate 0.2mg/kg and twelve patients (mdale 7, female 5, average 32.5 years old) with diazepam 0.3mg/kg. The results were summarized as follows. 1) Anesthesia was induced in all of midazolam group by one intravenous injection, but only 6 patients of diazepam group could induced by one injection and the other 6 patients needed 2 or more injections. 2) The changes of blood pressure and pulse rate after induction and intubation were almost similar in the two groups, but greater individual variation was seen in diazepam group. 3) A buring sensation following intravenous injection was noted in 11 cases of diazepam group, but none in midazolam group and no phlebitis in either group. From the above results, diazepam and midazolam are almost similar in nature but midazolam is definitely effective as an induction agent and has less side effects. Therefore midazolam maleate is regarded as a more effective agent than diazepam as an induction for general anesthesia.
박경규,박형근,김연수,이문성,김진오,조영덕,이영홍,봉형근,조주영,이준성,심찬섭,황성규,함정식,장재영,권귀향 대한내과학회 1997 대한내과학회지 Vol.53 No.2
Duodenal obstruction is the third leading cause of intrinsic obstruction of the alimentary tract in the newborn, the other causes are imperforate anus and esophageal atresia. If the obstruction is incomplete, as with a fenestrated duodenal membrane, the presentation of the symptoms may be delayed and the diagnosis overlooked. And so they are rarely diagnosed in the adult. Diagnosis can be made by contrast duodenography but is more definitive with endoscopy. This is the first case report of a 21-year-old female with duodenal membrane, associated with incomplete rotation of intestine and uterus bicornis, diagnosed by hypotonic duodenography and endoscopy, preoperatively, and successfully treated with duodenoduodenostomy.
브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구
황농문,방건웅,탁내형 한국열처리공학회 2000 熱處理工學會誌 Vol.13 No.1
Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is 30㎛/s of load application speed and 25 seconds of load application time.
이진명,허보경,황규석 한국산업안전학회 1998 한국안전학회지 Vol.13 No.1
Hazard and operability (HAZOP) analysis is one of the safety analysis method that is used in the chemical complex, because it can systematically identify causes and consequences of all the deviation that could occur. Since this method needs to hire specialized experts, it is costly and time-consuming. Therefore HAZOP Expert System has been developed to automate this analysis. This approach introduced object-oriented method and knowledge representation which is hierarchical tree of units to supply flexibility in the system, functional semantic network, propagation equation and rule-chaining method to set up the expert system for automating HAZOP analysis.