http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
염산티트라싸이클린의 적용시간에 따른 다공성 임프란트 표면 미세구조의 변화
정재욱,허익,권영혁,박준봉,정종혁,Jeong, Jae-Wook,Herr, Yeek,Kwon, Young-Hyuk,Park, Joon-Bong,Chung, Jong-Hyuk 대한치주과학회 2006 Journal of Periodontal & Implant Science Vol.36 No.2
Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline-hydrochloride(TC-HCI) on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and porous surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml TC-HCI solution for $\frac{1}{2}$ min., 1 min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}$ min. respectively in the test group and with no treatment in the control group. Then, specimens were processed for scanning electron microscopic observation. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml TC-HCI solution, in general, test specimens were similar to control. 3. In the porous surfaces, the control specimen showed spherical particles of titanium alloy and its surface have a few shallow ridges. The roughness of surfaces conditioned with tetracycline-HCI was lessened and seen crater-like irregular surfaces relative to the application time. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCI solution. But the porous surfaces conditioned with tetracycline-HCI solution began to be slightly changed from 2 min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.
정재욱,김종혁,김형남,김태우,Jeong, Jae-Wook,Kim, Jong-Hyuck,Kim, Hyeong-Nam,Kim, Tai-Woo 한국사물인터넷학회 2016 한국사물인터넷학회 논문지 Vol.2 No.3
These days, a lot of research has been in progress for a home automation system. In this study, the intelligent home automation system is developed for automatically controlling the temperature and illumination of the house. The difference with other research can be adjusted individually according to your taste and lifestyle of each individual, it is that it provides a more comfortable living environment through the accumulated lifestyle database. In addition, proposed system can use the mobile app to easily control the lighting devices, a electric fans, and heaters. Moreover the mobile app of proposed system offers function that allows you to search for residential environments statistics on their lifestyle. 요즘 홈오토메이션 시스템에 대한 연구가 많이 진행되고 있다. 본 연구에서는 지능형 홈오토메이션 시스템을 설계하여 집안의 온도와 조도를 자동적으로 조절하는 시스템을 개발한다. 다른 연구와의 다른 점은 각 개인의 생활 습관과 취향에 따라 개별적으로 조절할 수 있으며, 축적된 생활 습관 데이터베이스를 통해 보다 더 안락한 주거 환경을 제공한다는 점이다. 또한, 모바일 앱을 통해 가정 내의 조명과 선풍기, 히터 등을 손쉽게 제어할 수 있으며, 자신의 생활 습관에 대한 주거 환경 통계 자료를 검색할 수 있도록 하는 지능형 홈오토메이션 시스템을 제안한다.
비외상성 대퇴골두 무혈성 괴사에서 다발성 천공술 후 속발된 대퇴 전자하 골절 -1례 보고-
김종원 ( Jong Won Kim ),박현수 ( Hyun Soo Park ),라종득 ( Jong Deuk Rha ),장영수 ( Young Soo Jang ),정재욱 ( Jae Wook Jung ),양진필 ( Jin Phil Yang ),최재혁 ( Jae Hyuk Choi ) 대한고관절학회 2011 Hip and Pelvis Vol.23 No.2
대퇴골두 무혈성 괴사증의 치료에 있어서 다발성 천공술은 현재 널리 이용되고 있는 대퇴골두 구제 수술 중 하나이다. 다발성 천공술은 대퇴골두에 직경이 작은 Steinmann pin을 이용하여 피질골에 여러 개의 구멍을 뚫어 골수강 내를 감압하는 술식이다. 이는 대퇴골두 핵심 감압술의 일종으로 괴사골 내부로의 혈관 재형성을 도모함과 동시에 조직의 재생을 촉진하게 된다. 알려진 수술 후 합병증으로 천공 부위 근처에서의 이소성 골 형성과 더불어 드물게 대퇴골 전자하 골절의 발생가능성이 알려져왔다. 저자들은 다발성 천공술 후 6주가 경과한 후 발생한 대퇴골 전자하 골절을 경험하였기에 보고하고자 한다. Multiple drilling of the femoral head is a commonly-used surgical technique for the treatment of osteonecrosis. Several holes are drilled into the femoral head using a small-diameter Steinmann pin. This decompression technique promotes revascularization and regeneration of necrotic tissue in the femoral head. Known complications are heterotopic ossification and femoral subtrochanteric fractures, although these have only been rarely reported. Our case study focuses on a subtrochanteric fracture 6 weeks after a multiple drilling operation.
김종수 ( Jong Soo Kim ),정재욱 ( Jae Wook Jung ),송현주 ( Hyun Ju Song ),김정은 ( Jung Eun Kim ),이종우 ( Jong Woo Lee ),최정희 ( Jeong Hee Choi ),이영목 ( Young Mok Lee ),서유진 ( Yoo Jin Suh ),남동호 ( Dong Ho Nahm ),박해심 ( Ha 대한류마티스학회 2003 대한류마티스학회지 Vol.10 No.1
Dermatomyositis is a disease of non-pyogenic inflammation of skin and muscles in which tissues and cells are damaged by pathogenic autoantibodies and immune complexes. Diffuse subcutaneous and interstitial muscular calcinosis is well recognised and common in childhood dermatomyositis. However, soft tissue calcification in a patient with adult onset dermatomyositis has been rarely reported. We have experienced a patient with adult onset dermatomyositis who had diffuse subcutaneous tissue calcification on hands, arms, chest, abdomen and buttocks.
문종호(Jong-Ho Mun),남윤호(Yoon-Ho Nam),정재욱(Jae-Wook Jung),원동호(Dong-Ho Won) 한국컴퓨터정보학회 2012 한국컴퓨터정보학회 학술발표논문집 Vol.20 No.2
최근 다양하고 전문적인 웹 서비스와 어플리케이션들이 사용자를 위해 제공되고 있다. 이러한 서비스들은 보통 사용자의 인증을 거친 뒤 검증된 사용자에 한해 서비스를 제공하기 때문에 사용자는 매번 서비스별로 회원가입을 해야 하는 불편함을 겪고 있다. 이러한 불편함을 해결하기 위해 제 3의 서비스가 사용자의 보호된 데이터에 접근할 수 있도록 허가하는 OAuth 프로토콜이 등장하게 되었다. 본 논문에서는 OAuth 프로토콜의 동작과정과 문제점을 분석하고 피싱 공격 방어를 위한 확장된 프로토콜을 제안한다. 본 논문에서 제안하는 프로토콜은 기존의 OAuth 프로토콜에 인증 절차를 추가한 것이다.
김종면(Jong Myon Kim),정재욱(Jae Wook Jung),김철홍(Cheol Hong Kim) 한국정보과학회 2007 정보과학회 컴퓨팅의 실제 논문지 Vol.13 No.5
최근의 내장형 프로세서를 설계하는데 있어서는 성능 못지 않게 에너지 효율성이 중요하게 고려되어야 한다. 내장형 프로세서에서 소모되는 에너지의 상당 부분은 캐쉬 메모리에서 소모되는 것으로 알려지고 있다. 특히 1차 명령어 캐쉬는 거의 매 사이클마다 접근이 이루어지므로 상당히 많은 양의 동적에너지를 소모하게 된다. 그러므로, 내장형 프로세서를 설계하는데 있어서 1차 명령어 캐쉬의 에너지 효율성을 높이는 기법은 프로세서의 총 에너지 소모를 줄여주는 결과로 이어질 것으로 기대된다. 본 논문에서는 내장형 프로세서에 적합한 저전력 1차 명령어 캐쉬를 설계하는 기법을 제안하고자 한다. 제안하는 기법은 명령어 캐쉬를 여러 개의 작은 서브 캐쉬들로 분할하는 기법을 통해 명령어 접근 시 활성화되는 캐쉬의 크기를 줄임으로써 1차 명령어 캐쉬에서 소모되는 동적 에너지를 감소시켜 준다. 또한, 하나의 서브캐쉬 크기를 페이지 크기와 동일하게 함으로써 캐쉬 내에서 태그가 차지하는 칩 공간을 없애고, 태그 비교에 소모되는 에너지도 없애는 효과를 얻는다. 제안하는 1차 명령어 캐쉬는 물리적인 접근 시간 감소를 통해 캐쉬 분할로 인한 성능 저하를 최대한 줄이고, 에너지 감소 효과는 최대로 얻고자 한다. 모의 실험결과, 제안하는 구조는 기존의 1차 명령어 캐쉬 구조와 비교하여 명령어 접근에 소모되는 동적 에너지를 평균 37% ~ 60% 감소시키는 결과를 보인다. Energy consumption in the instruction cacheaccounts for a significant portion of the total processor energy consumption. Therefore, reducing energy consumption in the instruction cache is important in designing embedded processors. This paper proposes a method for reducing dynamic energy consumption in the instruction cache by partitioning it to smaller (less energy-consuming) sub-caches. When a request comes into the proposed cache, only one sub-cache is accessed by utilizing the locality of applications. By contrast, the other sub-caches are not accessed, leading todynamic energy reduction. In addition, the proposed cache reduces dynamic energy consumption by eliminating the energy consumed in tag matching. We evaluated the energy efficiency by running cycle accurate simulator, SimpleScalar, with power parameters obtained from CACTI. Simulation results show that the proposed cache reduces dynamic energy consumption by 37%~60% compared to the traditional direct-mapped instruction cache.
급성 외상성 근위 슬괵근 파열에서의 수술적 치료 -증례보고-
장영수,라종득,정재욱,양진필,Jang, Young-Soo,Rha, Jong-Deuk,Jung, Jae-Wook,Yang, Jin-Phil 대한정형외과스포츠의학회 2010 대한정형외과스포츠의학회지 Vol.9 No.2
대퇴부 슬괵근의 외상성 손상은 스포츠 손상에서 흔히 볼 수 있는 손상으로 보존적 치료가 가능한 단순한 근 긴장에서부터 수술적 치료가 반드시 필요한 완전 파열에 이르기까지 넓은 범주를 이룬다. 그 중에서 슬괵근의 기시부에 가까운 부위에서의 파열은 비교적 드문 경우로 수술적 치료가 반드시 필요하고, 만약 적절한 치료가 이루어지지 않으면 여러 가지 합병증을 야기한다고 알려져 있다. 저자들은 근위 슬괵근의 급성 외상성 파열에 대해 수술적 치료를 성공적으로 치험한 바 이를 보고하고, 상기 손상에 대해 고찰하고자 한다. The hamstring muscle injury is a quite common sports injury which has a wide spectrum of treatment option that simple muscle strain can be treated conservatively otherwise total rupture of muscle or musculotendinous junction must be treated surgically. Among them, rupture of proximal hamstring muscle near at its origin site is quite uncommon and it should be treated surgically because it could cause several complications if not treated appropriately. In this case report, the authors report successful surgical treatment of acute rupture of proximal hamstring muscle and also would like to review the clinical presentation of this type of injury.