http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
강성규,홍정표,김기웅,장재연,정호근,정규철 大韓産業醫學會 1994 대한직업환경의학회지 Vol.6 No.2
Twenty-four factories registered at the Ministry of Labor as factories using or producing cadmium in 1991 were investigated to know the present state of occupational exposure to cadmium in 1992. Nine factories among 24 stopped using or changed to other substances and 1 factory didn't produce any more, but delivered it to other factories through imports. Therefore, only 14 factories were producing or using cadmium. But, alloying materials were supplied to about 20 and more factories, however, they couldn't be investigated because of limited information. Three factories had less than 50 workers were 3,6 had 50-300 and 5 had more than 300. About 167 workers were exposed to cadmium. According to the classification by process, there were 4 alloy processes, 2 refinary, 2 elctroplating, 2 dry cell making, 1 industrial battery making, 1 duplicator drum making, 1 recycling of battery and 1 copper refinary. 8 factories used metal cadmium, 3 cadmium oxide, 2 cadmium sulfide, and 1 cadmium hyroxide. One factory was importing cadmium stearates only and supplying them to the PVC making factories. The amount of metal cadmium producing in 2 refinary factories was about 50-65 ton per month. The other cadmium compounds were imported. According to exposure level of cadmium air of the 10 factories examined, each factory could be divided into high, moderate and low exposure groups. 1 battery recycling factory and 3 alloy factories were in the high exposure group and their mean air concentrations were 0.06679, 0.05481, 0.02492, and 0.003㎎/㎥, respectively. Refinary and industrial battery making factories were in the middle exposure group and their mean air concentrations were 0.00773 and 0.00613 ㎎/㎥, respectively. Finally, low exposure group were copper smelting, dry cell case making, duplicator drum making and electroplating factory and their mean air concentrations were 0.00096, 0.00071, 0.00057 and 0.00054 ㎎/㎥ respectively.
대퇴동맥을 통한 경피적 관동맥 중재시술 환자의 천자부위 지혈을 위한 Angioseal^(�) 사용과 고식적 용수 압박법의 비교 : 전향적 연구
김용훈,권현철,김필호,안석진,유철웅,최진호,이상철,김준수,김덕경,전은석,이상훈,홍경표,박정의,서정돈 대한내과학회 2004 대한내과학회지 Vol.66 No.5
목적 : 경피적 관동맥 중재술은 최근 양적 및 질적으로 급격한 발전을 보였지만 시술 시 천자부위의 혈관 합병증은 아직 해결해야 할 문제점이다. 저자들은 대퇴동맥을 통한 경피적 관동맥 중재술을 환자에게 천자부위 지혈을 위한 혈관폐쇄기구인 안지오실의 안전성과 유용성을 고식적인 용수 압박법과 비교 연구하고자 하였다. 방법 : 2002년 4월부터 2003년 5월 사이에 삼성서울병원 심장혈관센터에서 대퇴동맥을 통한 경피적 관동맥 중재술을 성공적으로 시행한 200명의 환자(안지오실 사용군: A군, 100명, 고식적 용수압박법 사용군 B군, 100명)를 대상으로 시술 후 주요 합병증 및 경한 합병증, 지혈 후 환자가 자리에 앉기까지의 시간, 보행개시 가능시간, 총 재원 기간과 시술 1주 후의 합병증을 전향적으로 조사하여 비교 연구하였다. 결론 : 두 군에서 연령, 성별, 기저질환, 심혈관 질환의 위험요소, 시술의 종류, 시술 중 사용한 헤파린의 양, clopidogrel의 양, ticlopidine의 양, 지혈 시 수축기와 확장기혈압, ACT (activated clotting time)는 차이가 없었다. A군이 B군에 비해 시술 후 자리에 앉기까지의 시간 (A군: 4.3±0.3시간, B군: 13.7±0.8시간, p=0.004) 및 보행개시까지의 시간(A군: 6.8±0.5시간, B군: 18.8±2.1시간, p=0.013)이 유의하게 짧았다. 시술 후 주요 합병증은 두군 모두에서 관찰되지 않았으며, 경한 합병증의 전체발생은 A군에서 유의하게 적었다(A군: 28명, B군: 19명, p=0.003). 반상출혈의 경우는 A군에서 유의하게 낮았지만(A군: 3명, B군: 12명, p=0.01), 혈종, 출혈의 발생은 두군간에 차이가 없었다. 총 재원기간에는 두 군간에 차이가 없었다(p=0.239). 시술 1주 후 경과관찰에서 주요합병증은 역시 두 군 모두에서 관찰되지 않았으며, 경한 합병증의 전체발생은 두 군에서 차이가 없었다(A군: 15명, B군: 13명 p=0.418), 반상출혈의 빈도는 차이가 없었지만 혈종의 발생은 A군에서 더 낮았다(A군: 2명, B군:6명, p=0.004). 두 군 모두에서 출혈은 발생하지 않았다. 결론 : 대퇴동맥을 통한 경피적 관동맥 중재술을 시행한 환자에서 안지오실의 사용은 고식적 용수 압박법에 비해 환자의 침상 안정시간을 줄여 조기 활동개시가 가능하게 하였으며 국소합병증의 위험도를 일부 낮추어, 시술에 따른 환자의 불편을 현저하게 감소시킬 수 있다고 할 수 있을 것으로 기대된다. Background : Although the number and the quality of percutaneous coronary intervention have been recently increased dramatically, the vascular complication at puncture site is still the major cause of patients' morbidity. We evaluated the safety and efficacy of newly of newly-developed collagen-based arterial closure device, Angioseal after transfemoral percuatenous coronary intervention. Methods : This study was designed as a prospective single center non-randomized comparative study. A total 200 patients undergoing transfemoral percutaneous coronary intervention were enrolled between April 2002 and May 2003. They were divided into two groups; Angioseal group (group A, n=100) and manual compression group (group B, n=100). The baseline clinical and angiographic characteristics were reviewed. The time to sit up, the time to ambulation, the duration of hospital stay, major and minor vascular puncture site complications were monitored. The patients were followed-up for 1 week after procedure by telephone. Results : The baseline clinical characteriwtics, clinical diagnosis, cardiocascular risk factors, typesof procedure, doses and numbers of anticoagulants were similar between two groups. The blood pressure and activated clotting time were also similar. The time to sit up (group A: 4.3±0.3 hours, group B: 13.7±0.8 hours, p=0.004) and the time to ambulation (group A: 6.8±0.5 hours, group B: 18.8±2.1 hours, p=0.013) were shorter in group A. No major vascular complications were noted. The incidence of hematoma and bleeding were not significantly different between two groups. The incidence of ecchymosis, however, was significantly lower in group A (group A:12%, group B: 3%, p=0.001) The duration of gospital stay was similar between groups. During 7 days of follow-up period incidence of hematoma was significantly lower in group A (p=0.004). Although the incidence of ecchymosis was not significantly different between two groups. Conclusion : The angioseal may be associated with earlier ambulation and less patients' morbidity with low incidence of local complication rate compared to manual compression after transfemoral percutaneous coronary intervention.
그람양성구균에 대한 Teicoplanin과 Vancomycin의 시험관내 항균력
최태열,김경숙,전용관,서일혜,김정욱,이웅수,안정열,김홍석,정재용,최효선,김덕언,유진우 대한감염학회 1994 감염 Vol.26 No.1
An increasing frequency of methicillin resistant S. aureus(MRSA), methicillin resistant coagulase negative staphylococci(MRCNS) and Enterococcal infection have been observed in recent years. Teicoplanin is a new glycopeptide antibiotic obstained from the Actinoplanes teicomycetius. The molecular structure and spectrum of antimicrobial activity of teicoplanin is simillar to those of vancomycin, and has been reported to have an excellent in vitro and in vivo effect against various gram-positive infections. Therefore, we evaluated the in vitor susceptibility of gram positive cocci, such as, S. aureus, coagulase negative Staphylococci(CNS), and Enterococci to teicoplanin and vancomycin. The total 253 strains consisted of MSSA(40), MRSA(53), MSCNS(47), MRCNS(48), and Enterococci(65). They were assayed by disc diffusion and agar dilution. During the study, 57% of S. aureus and 49% of CNS showed resistance to methicillin. The inhibitory diameter of teicoplanin was 15-20mm in MSSA, 12-19mm in MRSA, 13-24mm in MSCNS, 11-23mm in MRCNS, and 15-22mm in Enterococci respectively, and showed sensitivity in all but 8 strains(3.2%). The range of the minimum inhibitory concentration (MIC) of teicoplanin to MSSA, MRSA, MSCNS, MRCNS and Enterococci were 9.12-2.0㎍/ml, 0.25-2.0㎍/ml, & 0.25-32㎍/ml, 0.12-1.0㎍/ml respectively. One case of S. haemolyticus was resistant to teicoplanin (32㎍/ml) by the agar dilution method. Eight minor (3.2%) and one major(0.4%) error was observed when the MIC and disk diffusion data were correlated with teicoplanin. As for vancomycin the inhibitory diameter was 17-21mm in MSSA, 15-21mm in MRSA, 18-26mm in MSCNS, 18-25mm in MRCNS, and 16-22mm in Enterococci respectively. The range of the MIC of vancomycin to MSSA, MRSA, MSCNS, MRCNS, and Enterococci were 0.25-1.0㎍/ml, 0.25-4.0㎍/ml, 0.5-2.0㎍/ml and 0.5-2.0㎍/ml respectively. One minor error (0.4%) was seen with the vancomycin disk. The MIC90 of MSSA and MRSA exhibited the same results in teicoplanin (1.0㎍/ml, 1.0㎍/ml), and vancomycin(2.0㎍/ml, 2.0㎍/ml). MSCNS and MRCNS exhibited greater MIC90 with teicoplanin(4.0㎍/ml, 8.0㎍/ml) than vancomycin(2.0㎍/ml, 2.0㎍/ml). Incontrase Enterococci were more susceptible to teicoplanin(0.5㎍/ml) than to vancomucin (2.0㎍/ml). Results from this analysis indicated that both teicoplanin and vancomycin were very excellent for gram positive infections, especially those resistant to methicillin.
Jeong-Woong Hong,김영민,윤성환,전민규 대한기계학회 2023 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.37 No.10
Combustion diagnosis is crucial for quantifying exhaust gas and calculating combustion efficiency. Temperature, concentration, and velocity measurements allow for the accurate identification of combustion conditions. However, the current diagnostic equipment used to assess the combustion state has various issues, such as flow disturbance caused by probes and measurement delays caused by sampling. Furthermore, using multiple measurement devices can be particularly inconvenient. This study confirmed the potential application of an exhaust gas emission and engine operation monitoring system by simultaneously measuring temperature, concentration, and velocity using tunable diode laser absorption spectroscopy (TDLAS) technology. To determine the combustion chamber of methane combustion, multiple laser beams that are separated using a beam splitter were arranged in various forms to measure temperature, concentration, and velocity. The reconstructed temperature and concentration distribution results for each position of the measurement cell case showed similar trends at identical measurement positions. Additionally, experiments confirmed that the velocity measured by laser crossing at a 45-degree angle from the center increased as the supply gas flow rate increased.
Various surgical strategies for hepatocellular carcinoma located in caudate lobe
Jeong-Moo LEE,Kyung-Suk SUH,Kwangpyo HONG,Eui Soo HAN,Sanggyun SUH,Su young HONG,Suk Kyun HONG,YoungRok CHOI,Nam-Joon YI,Kwang-Woong LEE,Jae-Hyung CHO 한국간담췌외과학회 2021 Annals of hepato-biliary-pancreatic surgery Vol.25 No.-