RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIEKCI등재

        Temporal trends and in-hospital outcomes of primary percutaneous coronary intervention in nonagenarians with ST-segment elevation myocardial infarction

        ( Joon Young Kim ),( Myung Ho Jeong ),( Yong Woo Choi ),( Yong Keun Ahn ),( Shung Chull Chae ),( Seung Ho Hur ),( Taek Jong Hong ),( Young Jo Kim ),( In Whan Seong ),( In Ho Chae ),( Myeong Chan Cho ) 대한내과학회 2015 The Korean Journal of Internal Medicine Vol.30 No.6

        Background/Aims: Data regarding the outcomes of primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) in nonagenarians are very limited. The aim of the present study was to evaluate the temporal trends and in-hospital outcomes of primary PCI in nonagenarian STEMI patients. Methods: We retrospectively reviewed data from the Korea Acute Myocardial Infarction Registry (KAMIR) from November 2005 to January 2008, and from the Korea Working Group on Myocardial Infarction (KorMI) from February 2008 to May 2010. Results: During this period, the proportion of nonagenarians among STEMI patients more than doubled (0.59% in KAMIR vs. 1.35% in KorMI), and the rate of use of primary PCI also increased (from 62.5% in KAMIR to 81.0% in KorMI). We identified 84 eligible study patients for which the overall in-hospital mortality rate was 21.4% (25.0% in KAMIR vs. 20.3% in KorMI, p = 0.919). Multivariate analysis identified two independent predictors of in-hospital mortality, namely a final Thrombolysis in Myocardial Infarction (TIMI) flow < 3 (odds ratio [OR], 13.7; 95% confidence interval [CI], 3.2 to 59.0; p < 0.001) and cardiogenic shock during hospitalization (OR, 6.7; 95% CI, 1.5 to 30.3; p = 0.013). Conclusions: The number of nonagenarian STEMI patients who have undergone primary PCI has increased. Although a final TIMI flow < 3 and cardiogenic shock are independent predictors of in-hospital mortality, primary PCI can be performed with a high success rate and an acceptable in-hospital mortality rate.

      • 가막만에 출현하는 동물플랑크톤의 종조성과 계절별 출현 양상

        서호영,이인태,윤양호,최상덕,이삼노,한명일,김병섭,강윤호,이우범 한국환경생물학회 2002 환경생물 : 환경생물학회지 Vol.20 No.2

        가막만에 출현하는 동물플랑크톤을 계절별(2001년 4월, 7월, 9월, 12월)로 Norpac네트를 이용하여 수직 채집하였다. 우점적으로 출현한 분류군은 4월과 12월에 요각류, 7월에 요각류와 지각류,9월에 야광충이었다. 출현 개체수는 22~17,197indiv. m^-3으로 시·공간적으로 변동폭이 매우 컸다. 요각류의 우점종은 4월에 Euryte-mora pacifica, Acartio omorii, Cenfropages abdominalis, Colanus sinicus, 7월에 Lobidocera rofunda와 A. erythraea, 9월에 A. eryfhraea와 Paracalanus parvus s. l., 12월에 A. omorii와 E. pacifca로 주로 내만종으로 변하였다. 그러나, 9월에 외양종인 Eucalanus sp.와 Neo-calnus sp. 또한 다수 출현하였다. 이와 같은 출현 경향은 가막만이 폐쇄성 내만임에도 불구하고 동물플랑크톤의 분포 특성은 내만수 이외에 계절적으로 외만수의 영향을 강하게 받고 있음을 암시하고 있다. Zooplankton was sampled vertically with a Norpac net from Gamag Bay in April, July, September and December, 2001. Copepods were predominant in April and December, and cladocerans in July and Noctiluca scintillans in September, respectively. There are high spatio-temporal fluctuations in the abundance of zooplankton with a range of 22∼17,197 indiv./㎥. In the copepod community, neritic species, Eurytemora pacifica, Acartia omorii, Centropages abdominalis and Calanus sinicus were predominant in April; Labidocera rotunda and A. erythraea in July; A. erythraea and Paracalanus parvus s. l. in September; A. omorii and E. pacifica in December. However, oceanic species Eucalanus sp. and Neocalanus sp. were abundant in September. It indicates that although Gamag Bay is semi-closed, the distribution pattern of zooplankton is seasonally strongly affected by oceanic waters in addition to neritic ones.

      • KCI등재

        가곡 스카른 광상 월곡-선곡 광체의 광물.지구화학적 특성: 성인적 의미

        최부갑,최선규,서지은,유인걸,강흥석,구민호,Choi, Bu-Kap,Choi, Seou-Gyu,Seo, Ji-Eun,Yoo, In-Kol,Kang, Heung-Suk,Koo, Min-Ho 대한자원환경지질학회 2010 자원환경지질 Vol.43 No.5

        가곡 스카른 광상은 고생대 조선누층군 석회질암을 관입한 백악기 화강암체의 접촉부를 따라 층상으로 교대된 광상으로 구성되어 있다. 관계화성암인 반심성암체는 석영몬조암~화강반암 조성과 함께 I형, 칼크-알카리 계열, 고알루미나질 지화학적 특정을 보이며, 가곡 Zn-Pb 광상에서는 내성스카른과 비하여 외성스카른이 광범위하게 배태되어 있다. 선곡과 월곡 지역의 광체에서 지화학적/광물학적 특성은 관계화성암으로부터 근접성에 의하여 좌우되고 있다. 가곡 광산의 섬아연석에는 Mn, Cd, Cu, In 성분이 미량 함유되어 있고, 정출온도 차이 및 분화과정을 통하여 차별화된 농집 과정이 유도됨으로서 광체에 따라 미량원소의 차이를 보이고 있다. 광석 중 높은 In/Zn비와 Cd/Zn비 그리고 섬아연석 중 낮은 Mn/Zn비는 마그마로부터 공급된 근원물질의 근접성과 밀접한 연관성을 보이고 있다. 따라서, 광석과 섬아연석에 함유된 미량원소의 농집 양상은 정출온도와 광화유체의 근원물질과 관련된 광체의 지화학적/광물학적 차별성을 인지할 수 있는 중요한 지시자로 이용될 수 있다. The Gagok stratabound skarn deposit is the result of the intrusion of the Cretaceous granitic pluton into the Paleozoic calcareous rocks. The subvolcanic intrusion ranges in composition from quartz monzonite to granite porphyry with I-type, calc-alkaline and weakly peraluminous characteristics. Both endoskarn and exoskarn are developed at the Gagok Zn-(Pb) deposit, with more exoskarn than endoskarn. Geochemical and mineralogical characteristics in the Seongok and Wolgok orebodies can be treated in terms of self-organization. Sphalerites in the Gagok ore can also incorporate minor amounts of Mn, Cd, Cu and In. Trace element concentrations in different orebodies vary because fractionation of a given element into sphalerite is influenced by formation temperature and the amount of sphalerite in the ore. A group of high In/Zn and Cd/Zn ratios in ores, and low Mn/Fe ratios in sphalerites are correlated with proximal processes of a magmatic source. The pattern of minor/trace element variations in ores and sphalcrites can be used for petrogenetic interprctation, e.g., orebody zonation related to crystallization temperature and fluid d sources.

      • 한의진단명과 진단요건의 표준화 연구 III : 3차년도 연구결과 보고

        최선미,양기상,최승훈,박경모,박종현,심범상,김성우,노석선,이인선,정진홍,이진용,김달래,임형호,김윤범,박성식,송태원,김종우,이승기,최윤정,신순식 한국한의학연구원 1997 한국한의학연구원논문집 Vol.3 No.1

        The diagnostic requirements were suggested and explained regarding the systems of differentiation of symptoms and signs in the third year study of standardization and unification of the terms and conditions used for diagnosis in oriental medicine. The systems were as follows : - analyzing and differentiating of epidemic febrile disease - analyzing and differentiating in accordance with the Sasang constitution medicine based on four-type recognition - differentiation of disease according to pathological changes of Chong and Ren channels - standards for diagnosis of women's disease - standards for diagnosis of children's disease - standards for diagnosis of motor and sensor disturbance (-muscle. born, joint, etc.) - standards for diagnosis of neuropsychiatric disease - standards for diagnosis of five sense organ disease - standards for diagnosis of external disease The indivisual diagnosis pattern was arranged by the diagnostic requirements in the following order : another name, notion of diagnosis pattern, index of differentiation of symptoms and signs, the main point of diagnosis, analysis of diagnosis pattern, discrimination of diagnosis pattern, prognosis, a way of curing a disease, prescription, herbs in common use, disease appearing the diagnosis pattern, documents. The standards for diagnosis of each disease was arranged by the diagnostic requirements in the following order : another name, notion of disease, the main point of diagnosis, analyzing and differentiating of disease, analysis of disease, discrimination of disease, prognosis, a way of curing and prescription of disease, disease in western medicine appearing the disease in oriental medicine, documents.

      • KCI등재

        Incidence of Adult In-Hospital Cardiac Arrest Using National Representative Patient Sample in Korea

        Yuri Choi,In Ho Kwon,정진우,정준영,노영훈 대한의료정보학회 2016 Healthcare Informatics Research Vol.22 No.4

        Objectives: This study analyzed the incidence and characteristics of in-hospital cardiac arrest (IHCA) in Korea based on a sample group of patients that is representative of the population. Methods: The incidence of IHCA in adults was extracted from HIRA-NIS-2009, a sample of all patients using medical services in Korea. IHCA patients were analyzed according to gender, age, type of medical institute, and classification under the 6th revision of the Korean Standard Classification of Diseases (KCD-6). In addition, to assess the differences arising from the size of medical institutes, the IHCA incidence was analyzed in relation to the number of inpatient beds. Results: Based on the sample data, the total incidence of IHCA in Korea was found to be 2.46 per 1,000 admissions (95% confidence interval [CI], 2.37–2.55). A higher incidence was found among men at 3.18 (95% CI, 3.03–3.33), compared to women at 1.84 (95% CI, 1.74–1.94). The incidence of IHCA was also higher in hospitals that had more than 600 inpatients beds at 5.40 (95% CI, 5.16–5.66) in comparison to those that had less than 600 inpatients beds at 4.09 (95% CI, 3.76–4.36) (p < 0.001). By primary disease, the incidence was the highest for infectious diseases. Conclusions: We demonstrated that the IHCA incidence based on gender, age, diagnostic group, and number of beds could be analyzed using the insurance claim data from a national representative sample.

      • KCI등재

        Enhanced Antitumor Effect of the Combination of Bacille Calmette-Guérin and an Immune Checkpoint Inhibitor in Bladder Cancer-On-a-Chip

        Choi Se Young,Kim Mirinae,Kang Su Jeong,Choi Young Wook,맹세정,Kim Sung-Hwan,Chang In Ho 한국바이오칩학회 2023 BioChip Journal Vol.17 No.4

        We upgraded preexisting bladder cancer-on-a-chip (BCOC) by adding T cells and evaluated the antitumor eff ect of a combina- tion of intravesical Bacille Calmette-Guérin (BCG) and pembrolizumab. We fabricated bioprinted BCOC with microfl uids, incorporating HT1376, MRC-5, HUVEC, THP-1 and Jurkat cells. We evaluated the eff ector-to-target cytotoxicity, cytokine, and cell viability in 2D culture, live/dead assay, migration assay, and cytokine assay in BCOC. Additionally, we evaluated the antitumor effi cacy of the combination of BCG and pembrolizumab in an orthotopic mouse model. The combination group showed the most eff ective reduction compared to the control in 2D culture (100.0 ± 0.8% vs. 36.4 ± 0.8%, p < 0.001). In BCOC, cancer cell viabilities were decreased at 3 days in the BCG group (70.1 ± 9.8%, p = 0.013) and combination group (49.3 ± 8.1%, p < 0.001). The combination group showed the highest immune reaction in the cytokine assay (interferon-γ, p = 0.045; interleukin-6, p = 0.037) and migration assay (fold change 1.3 ± 0.1, p < 0.001), whereas in the in vivo model, it showed lower signal intensities from days 10 to 14 compared to that in the control group ( p = 0.031 and p = 0.014, respec- tively). No signifi cant weight changes were observed among the groups. We developed a 3D bioprinted BCOC via use of the monocytic THP-1 cells and Jurkat T cells to assess the effi cacy of immunotherapy. The combination of BCG and pem- brolizumab showed the best antitumor effi cacy in BCOC and animal models.

      • SCIESCOPUSKCI등재
      • KCI등재후보

        적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석

        최성아,김선호,황윤찬,윤창,오병주,최보영,정우남,정선와,황인남,오원만 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.4

        This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The heat carrier system 'System B' (Model 1005. Analytic Technologies, USA) and the Buchanan's pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infraed thermography (Radiation Thermometer-IR temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it(p<0.001). 2. When the pluggers were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3±10.5℃ to 192.1±3.3℃ in a touch for 1 sec, from 218.6±5.0℃ to 179.5±4.2℃ in a touch for 2 sec, from 197.5±3.0℃ to 167.6±3.7℃ in a touch for 3 sec, from 183.7±2.5℃ to 159.8±3.6℃ in a touch for 4 sec and from 164.9±2.0℃ to 158.4±1.8℃ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temerature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature dose not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommended, and finally a quick touch of heat control spring for 1 sec reveals the highest temperature rise.

      • KCI등재후보

        수리된 복합레진 수복물의 전달결합강도 연구

        최수영,정선와,황윤찬,김선호,윤창,오원만,황인남 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.6

        This study was performed to evaluate the interfacial shear bond strength of base (direct and indirect) and repair composites with aging and surface treatment methods. Direct composites resin specimens (Charisma®, Heraeus Kulzer, Germany) were aged for 5 min, 1 hour, 24 hours, and 1 week in 37℃ distilled water before surface treatment, and then divided into five groups: Group 1, grinding; Group 2, grinding and application of bonding agent; Group 3, grinding, etching with 37% phosphoric acid for 30sec, and application of bonding agent; Group 4, grinding, etching with 37% phosphoric acid for 30sec, silane treatment, and application of bonding agent; Group 5, grinding, etching with 4% hydrofluoric acid for 30sec, silane treatment, and application of bonding agent. Indirect composite resin specimens (Artglass®, Heraeus Kulzer, Germany) were aged for 1 week in 37℃ distilled water and divided into seven groups: Group 1 - Group 5, equal to Charisma specimens; Group 6, grinding, etching 37% phosphoric acid for 60sec, silane treatment, and application of bonding agent; Group 7, grinding, etching with 4% hydrofluoric acid for 60 sec, silane treatment, and application of bonding agent. The repair material(Charisma®) was then added on the center of the surface (5mm in diameter, 5mm in height). The shear bond strength was tested and the data was analyzed using one-way ANOVA and the Student-Newman-Keuls test. The following conclusions were drawn. 1. The shear bond strength of Charisma® specimens aged for 1 hour was significantly higher in Group 2 and Group 5 than in Group 1 (p<0.05), and that of Charisma® specimens aged for 1 week was significantly higher in Group 3 and Group 5 than in Group 1 (p<0.05). No significant difference was found in the bond strength of specimens aged for 5 min and 24 hours. 2. In Group 2 of the Charisma® specimens, there was significant difference between the bond strength of 24 hours and that of 1 week (p<0.05). 3. In Group 4 of the Charisma® specimens, the shear bond strength of specimens aged for 24 hours was significantly higher than the others(p<0.05). 4. There was no significant diiference between the shear bond strength of the Artglass® specimens. 5. Most of the Charisma® specimens showed cohesive fractures. Artglass® specimens that were etched with acid(phosphoric or hydrofluoric) for 30 sec showed more cohesive fractures.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼