RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Inhibition of p38 pathway-dependent MPTP-induced dopminergic neurodegeneration in estrogen receptor alpha knockout mice

        ( Chul Ju Hwang ),( Dong Young Choi ),( Yu Yeon Jung ),( Young Jung Lee ),( Jae Suk Yun ),( Ki Wan Oh ),( Sang Bae Han ),( Seikwan Oh ),( Mi Hee Park ),( Jin Tae Hong ) 영남대학교 약품개발연구소 2016 영남대학교 약품개발연구소 연구업적집 Vol.26 No.-

        Approximately, 7-10 million people in the world suffer from Parkinson``s disease (PO), Recently, increasing evi-dence has suggested the protective effect of estrogens against nigrostriatal dopaminergic damage in PD. In this study, we investigated whether estrogen affects l-methyl-4-phenyl-l,2,3,6-tetrahydropyridine (MPTP)-induced behavioral impairment in estrogen receptor alpha (ERa)-deficient mice. MPTP (15 mg/kg, four times with l.5-h interval)-induced dopaminergic neurodegeneration was evaluated in ERα wild-type (WT) and knockout (KO) mice. Larger dopamine depletion, behavioral impairments (Rotarod test, Pole test, and Gait test), activation of mi-croglia and astrocytes, and neurointlammation after MPTP injection were observed in ERα KO mice compared to those in WT mice.Immunostaining for tyrosine hydroxylase (TH) after MPTP injection showed fewerTH-positive neurons in ERα KO mice than WT mice. Levels of dopamine and 3,4-<lihydroxyphenylacetic acid (OOPAC, metab-olite of dopamine) were also lowered in ERα KO mice after MPTP injection. Interestingly, a higher immunoreac-tivity for monoamine oxidase (MAO) B was found in the substantia nigra and striatum of ERα KO mice after MPTP injection. We also found an increased activation of p38 kinase (which positively regulates MAO B expression) in ERα KO mice. In vitro estrogen treatment inhibited neuroinflammation in l-methyl-4-phenyl pyridium (MPP +)-treated cultured astrocyte cells; however, these inhibitory effects were removed by p38 inhibitor. These results indicate that ERα might be important for dopaminergic neuronal survival through inhibition of p38 pathway.

      • SCOPUSSCIEKCI등재

        수종 교정용 접착제의 전단 접착강도 비교

        유미희,황충주 대한치과교정학회 1994 대한치과교정학회지 Vol.24 No.2

        Bonding of brackets is one of the essential factors for successful orthodontic treatment, so bond strength of orthodontic adhesives are very important. The purposes of this research were to compare shear bond strength of various orthodontic adhesives and to evaluate failure sites. One-hundred twenty extracted human first premolars were prepared for bonding and premolar brackets were bonded to prepared enamel surfaces with super C Ortho, Mono-Lok², Transbond, and Super C Ortho after applying Fluorobond. After bonding of brackets, teeth specimens were divided into 3 groups. In group I specimens were stored at humidor 37℃ in 1 hours, in group 2 specimens were stored at humidor 37℃ in 24 times, thermocycled 10 times and in group 3 specimens were stored at humidor 37℃ in 24 hours, thermocycled 1800 times. Then the universal testing machine Instron 6022, Instron Co., U.S.A. was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites. The results were as follows: 1. Shear bond strength was significantly highest of using Super C Ortho after applying Fluorobond and Super C Ortho In group 1, was highest of using super C Ortho in group 2, and was highest of using Mono-Lok²in group 3. 2. According to time and temperature change, in using Super C Ortho the group 2 had significantly highest strength and group 3 had lowest strength, than group 1 and in using Super C Ortho after applying Fluorobond shear bond strength decreased constantly. 3. The failure sites were tooth-resin interface in Super C Ortho after applying Fluorobond, Mono Lok²and Transbond and were at almost same ratio bracket base-resin interface and tooth-resin interface in Super C Orth.

      • 간접부착술식시 치면과 레진 베이스의 간격 및 접착제에 따른 결합강도

        서미영,박병주,경희문,황현식 전남대학교 치의학연구소 2001 구강과학 Vol.13 No.3

        The purpose of this study was to evaluate the feasibility of the combined use of paste resin with sealant as an adhesive of the indirect bonding. The resin bases made of lighcured resin were bonded to the bovine incisors at a distance of 0.0, 0.2 or 0.4mm using the sealant only or the mixture of sealant and paste resin. Bond strength of each group was measured using universal testing machine. The results were as follows: 1. The bond strength was reduced in both groups as the distance between enamel surface and resin base increased. 2. The bond strength showed no statistical difference between two groups in case the distance between enamel surface and resin base was 0.0mm. 3. In case the distance between enamel surface and resin base was 0.2 or 0.4mm, the sealant with paste resin group showed significantly higher bond strength than the sealant only group. The results of the present study indicate that the use of paste resin with sealant may be desirable as an adhesive in indirect bonding, particularly in case a gap is suspected between enamel surface and resin base.

      • ZnO 박막을 TCO로 사용한 염료감응형 태양전지의 제작

        박미주,공대영,황문식,마재평 호남대학교 정보통신연구소 2006 정보통신연구 Vol.16 No.-

        Dye-Sensitized Solar Cell was fabricated at general lab. with common and chief matters: TiO_(2) powder as semiconductor, Eosin-Y as dye, I^(-)/I_(3)^(-) as liquidus electrolyte, and Ag as bottom-electrode. And ZnO thin film as TCO was sputtered on the glass substrate. As a result, open-circuit voltage was generated in these samples. It was found that this cell that is fabricated under common conditions is commercially available.

      • KCI등재
      • KCI등재후보

        지혈제 오염이 콤포머의 전단결합강도에 미치는 영향

        허정무,곽주석,이황,이수종,임미경 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.2

        One of this latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent® (Ultradent product Inc., Utah, U.S.A.). Group 3: Dentin surface was not etched but was contaminated by Bosmin®(Jeil Pharm, Korea).). Group 4: Dentin surface was not etched but was contaminated by Epri-dent®(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin surface was etched had contaminated by Astringedent®. Group 7: Dentin surface was etched and contaminated by Bosmin®. Group 8: Dentin surface was etched and contaminated by Epri-dent®. Group 9: Dentin surface was contaminated by Astringedent®. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin®. The contaminated surface was rinsed by water and dried by compressed air. Group 11: Dentin surface was contaminated by Epri-dent®. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning. F2000® was applicated on the conditoned dentin surface. The teeth thermocycled in distilled water at 5℃ and 55℃ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface paralled to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed of 1.0mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

      • 간호중재분류체계(NIC)를 이용한 중환자실 간호중재 분석

        권경남,장희정,황운순,김은주,이미경 영남이공대학 산업기술연구소 2000 産業技術硏究 Vol.12 No.-

        The purpose of this research was to identify nursing interventions performed by the ICU nurses from 2 university hospital in Taegu. For this research, I used the Nursing Intervention questionnaire developed by the Iowa Intervention Project and translated by korean specialists and professor concerned to the same field. In order to obtain the data, a special group of professor, head nurse, charge nurse, researcher was instituted. The special group work validataed 205 nursing interventions with agreement of more than 50% becuse the NIC(433 nursing intervention) survey process was too time-consuming and not appropriate for all labels. The data were collected from June 1 to 30, 1999 and analysed with SAS program. The obtained results are as follows; (1) 94 interventions were performed at least daily. (2) The most frequently used nursing interventions were Parenteral Medication Administration, Aspiration Precautions, Pressure Ulcer Prevents, Positioning, Airway Management, Cough Enhancement in rank. In conclusion, this research using NIC has helped to figure out the component to the ICU care in korea. The use of this results will contribute to enhance quality assessment and improve standard of ICU nursing.

      • KCI등재후보
      • 어머니가 지각한 영아기질과 어머니 역할수행에 대한 자신감 및 만족도의 관계

        이영은,강양희,박혜선,황은주,문미영 고신대학교 전인간호과학연구소 2003 전인간호과학연구 학술모음집 Vol.2 No.-

        Method : The subjects of this study were 300 mothers of infant at the age of 1-12 months who visited well baby clinic in 4 hospitals in Busart city and Kyoung-Nam province. Final analysis was performed in 293 cases. Seven cases was excluded in this study because of its inappropriate data collection. The data was collected from 1st July to 15th August 2002. The questionnaries which were fill-up by mother were collected. Infant temperament was measured by using the tool of "what my baby is like''(WBL) which was developed by Priham et. al.(1994) and translated by Bang(1999). The scale of postpartum self evaluation which was developed by Lederman et al( 1981) and translated by Lee( 1992) was used for the confidence and satisfaction of maternal role. All statistical analyses were performed using SPSS-PC for window, version 10.0: frequency, percentage, minimum, maximum, mean, SD, t-test, ANOVA, Post-hoc test(Scheffe's test), Pearson Correlation Coefficients. Purpose : This study was intended to search the relationship between perception of the infant temperament in mother of infant at the age of 1-12 months and maternal confidence and satisfaction in performing maternal role, and to submit a basic data to establish a nursing intervention program which is helpful for determination of infant development and performing maternal role promotion by identify variables associated with infant temperament perception of the infant temperament was 6.17±1.04, and mother recognized her infant as positive. The mean score of confidence of maternal role was 2.89±.41 and this revealed in an average level. The mean score of satisfaction of maternal role was 3.29± .51 and this revealed in a higher level. There was a weak significant positive correlation between the score of maternal perception of infant temperament and confidence of maternal role(r=0.176, P= .003), but there was no significant correlation between satisfaction of maternal role(P> .05). It revealed the more maternal perception of the infant temperament as positive, the higher confidence of maternal role. There was a moderate significant positive correlation between confidence of maternal role and satisfaction of maternal role(r=0.410, P= .000). It revealed the more confidence of maternal role, the higher satisfaction of maternal role. The variables related with the score of maternal perception of infant temperament were the type of delivery (t=-2.600, P= .010), experience of learning baby care(t=2.382, P= .018), maternal perception on baby's health status(F=3.467, P= .033), maternal perception on her health status(F=3.467, P= .027), baby's age(F= .080, P= .028). Conclusion : Our result showed the confidence of maternal role was increased as the maternal perception of infant temperament was positive, and conformed that the confidence of maternal role was also related with satisfaction of maternal role. Prenatal education, type of delivery, baby's age were also related with the maternal perception of infant temperament. So, nursing intervention program of developmental stage maybe necessary in order to help maternal perception of infant temperament as positive, and it will be increased the confidence of maternal role and satisfaction of performing maternal role which was considered as real indicate of achievement of maternal role.

      • KCI등재후보

        감염근관에서 Black-Pigmented Bacteria의 동정에 대한 연구

        권은경,김은숙,곽주석,이황,이수종,임미경 大韓齒科保存學會 2002 Restorative Dentistry & Endodontics Vol.27 No.1

        Black-pigmented bacteria have been implicated in the endodontic infections. This group of microorganisms includes Porphyromonass endodontalis, Porphyromonas gingicalis, Prevotella intermedia, and Prevotella nigresceus. The organisms display a wide variety of virulence factors that may be pertinent to acute endodontic infections. The aim of this study was to identify P.endodontalis, P.gingivalis, P.intermedia, and P.nigrescens by using special potency disk test, filter paper spot test, 16S rRNA gene-directed PCR, and API 32A. Microbial samples were collected from root canals of 33 intact teeth with necrotic pulp and/or apical periodontitis. Conventional laboratory methods were used for identification of the strains of black pigmented bacteria. Eighteen of 33 samples were positive for the growth of black-pigmented bacteria. Five colonies were cultured from each pure cultured colonies from Brucella agar plate. Seventy seven colonies were positive for the growth of black-pigmented bacteria. Thirty three of 77(42.6%) were identifed as P.nigrescens, 10 of 77(12.9%) were P.gingivalis, 6 of 77(7.8%) were P.endodontalis, 10 of 77(12.9%) were P.intermedia. On the contraty the reference strains of P.nigrescens, experimental strains of P.nigrescens was sensitive to kanamycin in special potency disk test. 16S rRNA gene PCR and API test after rapid presumptative identification methods. such as special potency disk test and filter paper spot test, would be accurate detection methods for black-pigmented bacteria.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼