RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Biochemical Characteristics and Antimicrobials Susceptibility of Salmonella gallinarum Isolated in Korea

        Ki-seuk Kim,Young-ju Lee,Yong-kuk Kwon,Ryun-bin Tak 대한수의학회 2003 Journal of Veterinary Science Vol.4 No.2

        Characteristics and Antimicrobials Susceptibility of Salmonella gallinarum Isolated in KoreaYoung-ju Lee, Ki-seuk Kim1,*, Yong-kuk Kwon and Ryun-bin Tak1Avian Disease Division, National Veterinary Research and Quarantine Service, Anyang 430-824, Korea1College of Veterinary Medicine, Kyungpook National University, Daegu 702-701, KoreaReceived February 13, 2003 / Accepted April 30, 2003J. Vet. Sci. (2003), 4(2), 161-166JOURNAL OFVeterinaryScience*Corresponding author: Ki-seuk Kim College of Veterinary Medicine, Kyungpook National University, Daegu 702-701, Korea Tel: 82-53-950-5962, Fax: 82-53-950-5955 E-mail: kimkiseuk@knu.ac.kr

      • 전력계통 안정화용 초전도 에너지 저장장치의 최적정격 결정

        황석영,이혜경 단국대학교 1999 論文集 Vol.34 No.-

        Recently superconductive magnetic energy storage(SMES) has been studied for stabilizing electric power system due to simultaneous control of active and reactive power, high efficiency and rapid response. In this paper, a method for optimum determination for the required ratings of SMES for power system stability is proposed. In the method, maximum operating voltage level and ratio of minimum/maximum charging current of superconducting coil are used as important parameters.

      • KCI등재

        방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구

        송경석,권용식,한규태,정규혁,이용묵,유일재 한국산업위생학회 2001 한국산업보건학회지 Vol.11 No.1

        The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirator. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel are welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for comm hygienic mas was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62% 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

      • 회전전기기기의 회전동작과 페이서도와의 관계

        황석영,김영천,이해경 단국대학교 1996 論文集 Vol.30 No.-

        Energy conversion in rotating electric machines results from the relative movement of windings, magnetic flux and m.m.f which are elementary factors. In this paper, a technique repesenting the above 3 factors as space vectors in re-lative movement is proposed. The space vectors are related to phasors of A.C rotating machines under steady state. As a result of application of the technique, actual relative movements of machines corresponding to any phasor diagram are well visualized and especially concepts of torque producing mechanism is easily described.

      • 국가 대표급과 제주도 고교 대표급 수영선수들의 그랩 스타트의 운동학적 분석

        김철원,김승곤,오만원,임상용,김성찬,이창준,남사웅,이세형,류재청,신석종,김세민 濟州大學敎 體育科學硏究所 1998 체육과학연구 Vol.4 No.-

        The purpose of the study was to undertaken to analysis the Grab starting technique between national representive team(3) and Cheju's representive team(3) with 3D cinematography. The conclusions obtained were as follows: Cheju's showed more elapsed time than national representive team on starting block. and more vertical than horizontal direction of COG position, more concentrated vertical velocity & acceleration than forward direction. Therefore It is necessory for cheju's to train balanced trust force in horizontal and vertical direction in grab starting technique.

      • KCI등재

        Two-Stage Reimplantation in Infected Total Knee Arthroplasty

        Lee, Yong Seuk,Chen, Antonia F. Korean Knee Society 2018 대한슬관절학회지 Vol.30 No.2

        <P>Two-stage reimplantation is considered the gold standard for the management of periprosthetic joint infection. The first stage involves the removal of the prosthesis, followed by extensive debridement of all nonviable tissues, synovectomy, irrigation, and reaming of the medullary canals. Once the joint has been prepared, antibiotic-impregnated cement beads and/or spacer are inserted. Antibiotic-impregnated spacers are now more commonly used, and an increasing number of orthopaedic surgeons are using articulating spacers if indicated. Antibiotics are then prescribed to the patient based on the sensitivities of the infecting organism. The duration of systemic antibiotic use is decreasing, and short courses of antibiotic therapy have been shown to be as efficacious as prolonged therapy between the first and second stages. The second stage of the procedure involves removal of the antibiotic-impregnated cement beads and/or spacer, repeat irrigation and debridement, and final reconstruction with revision components. While two-stage reimplantation was considered the gold standard in many parts of the world, recent studies have demonstrated that it is associated with a considerable failure rate. This may be due to the lack of accurate diagnostic tools for infection eradication, and future investigation of risk factors for failure of the two-stage reimplantation should be conducted.</P>

      • KCI등재

        Comprehensive Analysis of Pain Management after Total Knee Arthroplasty

        ( Yong Seuk Lee ) 대한슬관절학회 2017 대한슬관절학회지 Vol.29 No.2

        Total knee arthroplasty (TKA) has been much improved recently and it is regarded as one of the most common and successful surgical procedures that provides pain relief and improves function in patients with severe knee arthritis. However, recent studies have reported that 15%-20% of patients are not satisfied after TKA without evident clinical or radiological findings and the most common causes of patient dissatisfaction include residual pain and limited function. The evaluation and treatment of painful TKA relies on a thorough understanding of the origin by careful evaluation, and a systematic approach is essential to efficiently and effectively resolve the pain. Periarticular injections (PAIs) and nerve blocks are gaining popularity because they are associated with less side effects than systemic regimens. The analgesic efficacy and safety of PAI compared with nerve blocks for postoperative pain management still remain controversial. Therefore, more study is needed to determine if any changes in the regimen of the injection or technique could provide added benefit to long-term functional improvement beyond the perioperative period.

      • SCISCIESCOPUS
      • Effect of the Timing of Anterior Cruciate Ligament Reconstruction on Clinical and Stability Outcomes: A Systematic Review and Meta-analysis

        Lee, Yong Seuk,Lee, O-Sung,Lee, Seung Hoon,Hui, Teo Seow Elsevier 2018 Arthroscopy Vol.34 No.2

        <P><B>Purpose</B></P> <P>The purpose of this systematic review and meta-analysis was to evaluate the effect of the timing of anterior cruciate ligament (ACL) reconstruction on clinical and stability outcomes by analyzing high-quality studies that assessed timing as a primary objective.</P> <P><B>Methods</B></P> <P>The MEDLINE, EMBASE, and Cochrane database were systematically searched. The inclusion criteria were as follows: (1) English articles, (2) noncomparative study or relevant study reporting clinical and/or stability results, and (3) timing of the ACL reconstruction as a primary objective. Study type, level of evidence, randomization method, exclusion criteria, number of cases, age, sex, timing of ACL reconstruction, follow-up, clinical outcomes, stability outcomes, and other relevant findings were recorded. Statistical analysis of the Lysholm scores and KT-1000 arthrometer measurements after early and delayed ACL reconstruction was performed using R version 3.3.1.</P> <P><B>Results</B></P> <P>Seven articles were included in the final analysis. There were 6 randomized controlled trials and 1 Level II study. Pooled analysis was performed using only Level I studies. All studies assessed the timing of ACL reconstruction as a primary objective. The definition of <I>early</I> ranged broadly from 9 days to 5 months and <I>delayed</I> ranged from 10 weeks to >24 months, and there was an overlap of the time intervals between some studies. The standard timing of the delayed reconstruction was around 10 weeks from injury in the pooled analysis. After pooling of data, clinical result was not statistically different between groups (<I>I</I> <SUP>2</SUP>: 47%, moderate level of heterogeneity). No statistically significant difference was observed in the KT-1000 arthrometer measurements between groups (<I>I</I> <SUP>2</SUP>: 76.2%, high level of heterogeneity) either.</P> <P><B>Conclusion</B></P> <P>This systematic review and meta-analysis performed using currently available high-quality literature provides relatively strong evidence that early ACL reconstruction results in good clinical and stability outcomes. Early ACL reconstruction results in comparable clinical and stability outcomes compared with delayed ACL reconstruction.</P> <P><B>Level of Evidence</B></P> <P>Level II, a systematic review and meta-analysis of Level I and II studies.</P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼