http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김정수,김성환,전민철,주원하,정민규,김미정,이승열,이태희,성열훈,Kim, Jung-Su,Kim, Sung-Hwan,Jeon, Min-Cheol,Ju, Won-Ha,Jeong, Min-Gyu,Kim, Mi-Jeong,Lee, Seung-Youl,Lee, Tae-Hee,Seoung, Youl-Hun 대한방사선과학회 2018 방사선기술과학 Vol.41 No.6
The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.
심뇌혈관 센터를 위한 Cardiac PACS의 도입과 적용 사례
김정수,조무성,Kim, Jung-Su,Cho, Moo-Seong 대한디지털의료영상학회 2010 대한디지털의료영상학회논문지 Vol.12 No.1
Based on the cardiac PACS application collected from three university hospitals across the country, this research showed us a composition method of a server and storage devices with conditions in the field. Also, we founded the practical use of software making the best of cardiovascular PACS features. In addition, it also examined the components and requirements of the key functions that are available in the cardiovascular sector. We will be investigated the design experience and applications on stable storage and transmission of large video clip data, cardiovascular analysis, and gear interlocks through the study.
김정수,정정화,Kim, Jung-Su,Chong, Jong-Wha 대한전자공학회 2002 電子工學會論文誌-SP (Signal processing) Vol.39 No.6
본 논문은 케이블 채널 등화에 이용 가능한 빠른 수렴 특성을 갖는 블라인드 결정 궤환 등화기를 제안한다. 전방향 및 궤환 필터로 구성되는 기존의 블라인드 결정 궤환 등화기는 에러 전파 문제를 피하기 위해 전방향 필터 계수가 충분히 수렴된 후, 궤환 필터 계수가 갱신되므로 정상 상태에 수렴하는데 많은 훈련시간이 걸리는 단점을 갖는다. 이런 단점을 극복하기 위해 제안된 등화기는 수신신호와 입력신호의 통계적 특성을 나타내는 대표값 사이의 최소 거리를 이용하는 새로운 비용함수를 전방향 필터에 적용하였다. 또한 계수 갱신에 이용되는 LMS 알고리즘의 수렴 상수를 등화기 출력에 따라 적응적으로 변화시킴으로써 궤환 필터의 수렴 속도를 향상시켰다. 제안된 등화기의 성능을 공인된 케이블 채널 환경하에서 모의실험 하였다. 그 결과, 제안된 등화기는 기존의 블라인드 등화기보다 빠른 수렴속도를 보였으며, SER 성능 비교에서도 기존의 블라인드 등화기보다 더 나은 결과를 나타내었다. 제안된 등화 기술을 유무선 멀티미디어 전송환경, 8-VSB 혹은 64-QAM 방식을 이용하는 지상파 HDTV 등에 적용하는 것을 기대할 수 있다. A new multi constant modulus algorithm (MCMA) for a blind decision feedback equalizer is proposed. In order to avoid the error propagation problem in the conventional DFE structure, Feed-Back Filter coefficients are updated only after Feed-Forward Filter coefficients are sufficiently converged to the steady state. Therefore, it has the problem of slow convergence speed characteristics. To overcome this drawback, the proposed MCMA algorithm uses not only new cost function considering the minimum distance between the received signal and the representative value containing the statistical characteristics of the transmitted signal, but also adaptive step-size according to the equalizer outputs to fast convergence speed of FBF. Simulations were carried out under the certified communication channel environment to evaluate a performance of the proposed equalizer. The simulation results show that the proposed equalizer has an improved convergence and SER performance compared with previous methods. The proposed techniques offer the possibility of practical equalization for cable modem and terrestrial HDTV broadcast (using 8-VSB or 64-QAM) applications.
스마트폰을 이용한 ECG Viewer의 임상적 타당성 검토
김정수,Kim, Jung-Su 대한디지털의료영상학회 2010 대한디지털의료영상학회논문지 Vol.12 No.1
The study was designed to transmit ECG(electrocardiogram) images from iPhone in order to check validity. Especially, web examined ECG transmissions from smart phones image viewer are good enough to secure clinical information and confirmed with visual. In result, it took 3 to 5 seconds for ECG viewer transmitting from a smart phone to display an image on mobile server to user's phone. For image valuation, we magnified the ECG image 100% or 200% at a resolution of $480{\times}320$ checking PQRST wave and found that it was both possible to see an accurate PQRST wave with all the trial data and to divide it into 1mm level of grid.
La$_2O_3$-변형 BaTi$O_3$의 안정한 결함구조
김정수,박휴범,안태호,김시중,Kim, Jeong Su,Park, Hyu Beom,An, Tae Ho,Kim, Si Jung 대한화학회 1994 대한화학회지 Vol.38 No.4
La$_2O_3$-변형 BaTi$O_3$의 안정한 결함구조와 단일상 영역을 X-선 회절분석기와 주사전자현미경을 사용하여 연구하였다. La$_2O_3$-변형 BaTi$O_3$의 안정한 결함구조는 La$^{3+}$ 이온이 격자구조내의 Ba$^{3+}$ 이온을 치환하고 Ti빈자리가 전하 불균형을 보상하기 위한 결함으로 생성된 [($Ba^x_{Ba})_{1-2x}(La{\cdot}_{Ba})_{2x}][Ti^x_{Ti})_{1-x/2}(V""_{Ti})_{x/2}]O_3$이다. 안정한 결함구조가 형성되도록 BaTi$O_3$에 La$_2O_3{\cdot}3/2TiO_3$를 혼입할 때 단위격자는 약 3 mol%가 혼입될 때부터 정방정에서 입방정으로 변하였고, 고용한계는 약 14 mol%이었다. La2$O_3{\cdot}3/2TiO_2$를 고용한계 이상으로 혼입할 때는 이차상으로 La_4Ba_2Ti_5O){18}$가 생성되었다. La$_2O_3$-변형 BaTi$O_3$ 조성에서 BaO가 과량 존재하면 소결성이 나쁘지만, Ti$O_2$가 과량으로 존재하면 액상소결에 의하여 소결성이 좋아짐을 확인할 수 있다. The stable defect structure and the single phase region of La$_2O_3$-modified BaTi$O_3$ have been studied by X-ray diffractometer and scanning electron microscope. The stable defect structure of La$_2O_3$-modified BaTi$O_3$ has been identified as [($Ba^x_{Ba})_{1-2x}(La{\cdot}_{Ba})_{2x}][Ti^x_{Ti})_{1-x/2}(V""_{Ti})_{x/2}]O_3$ which consists of La$^{3+}$ ion substitution for Ba$^{3+}$ ion in the lattice structure and the formation of Ti vacancies for the charge compensation. When 3 mol% of La$_2O_3{\cdot}3/2TiO_3$ was added to BaTi$O_3$, the unit cell structure was transformed from tetragonal to cubic and the solubility limit was about 14 mol%. When La$_2O_3{\cdot}3/2TiO_2$ was added above this solubility limit, the second phase, La$_4Ba_2Ti_5O_{18}$, was formed. In the La$_2O_3$-modified BaTi$O_3$, it was found by the liquid phase sintering process that the sinterability was decreased by excess BaO but increased by excess Ti$O_2$.
김정수,Kim, Jung-Su 한국데이터정보과학회 2016 한국데이터정보과학회지 Vol.27 No.6
ROTC is the system that selects the best students in university and implements the military training of two years and uses them as beginning commander of the army by commissioning as officers. ROTC makes up a very large portion of the army and society in Korea in terms of the size and role. Therefore, it is very important to enhance intangible combat power of the Korean army by improving leadership of primary grade officer from ROTC. The purpose of this paper is to investigate whether or not ROTC candidate training program is providing the right training, so as to improve ROTC's leadership and present improvement plan. First, we divide ROTC candidate training program into three areas and take the 1st and 2nd survey. Then we compare and analyze the actual condition and recognition of investigation using statistical analysis methods such as chi-square test, ANOVA and Duncan's multiple range test. Also, we analyze the element affecting the army leader's three qualities formation which are basic elements of ROTC cadet's leadership using multiple regression analysis. 학군장교 (ROTC)는 대학에 재학 중인 우수 학생들을 선발하여 2년간 군사교육을 실시하고 졸업과 동시에 장교로 임관시켜 군의 초급 지휘자로 활용하는 제도로서 규모나 역할로 봤을 때 우리나라의 군과 사회에서 차지하는 비중이 매우 크다. 따라서 ROTC 출신 초급장교들의 리더십을 향상시켜 우리나라 군의 무형 전투력을 성장시키는 것이 매우 중요하다. 본 연구의 목적은 학군장교 양성교육 프로그램이 학군장교 리더십을 향상시키기 위해 적절한 교육을 제공하고 있는지 파악하고 개선방안을 제시하는 데 있다. 먼저 학군장교 교육 프로그램을 크게 세 분야로 나누어 1, 2차 설문조사를 실시한 뒤, 카이제곱 검정 (chi-square test), 분산분석 (ANOVA), 던컨의 다중검정 (Duncan's multiple range test) 등의 통계분석 방법들을 이용하여 교육프로그램에 직간접적으로 관련된 조사대상자들의 교육에 대한 실태 및 인식을 비교 분석한다. 또한 다중회귀분석 (multiple regression analysis)을 이용하여 학군후보생 리더십의 기본요소인 육군리더의 3대자질 형성에 영향을 미치는 세부요소들을 분석한다.
RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정
김정수 ( Jung-su Kim ),김성환 ( Sung-hwan Kim ),김미정 ( Mi-jeong Kim ),이승열 ( Seung-youl Lee ),이태희 ( Tae-hee Lee ),성열훈 ( Youl-hun Seoung ) 한국방사선학회 2018 한국방사선학회 논문지 Vol.12 No.6
국제전기기술위원회의 문서 IEC 60601-1의 3판 규격과 IEC 60601-2-45의 개별 규격에서는 진단용 X선 장치에서 X선 피폭 선량 정보를 표시하고 그 정확성을 명시할 것을 권고하고 있다. 하지만 임상에서 사용하는 부착형 공기커마 면적선량계는 교정에 어려움이 있다. 이에 본 연구에서는 임상에 적용 가능한 RQR 표준 선질을 이용하여 공기커마 면적선량계의 에너지 의존성과 정확도를 평가하였고 임상에서 간접 교정을 시행할 수 있도록 방법론을 마련하고자 하였다. RQR5의 표준 선질에서 시행한 시험에서 부착형 공기커마 면적선량계는 -7.5%의 오차를 나타냈고, RQR8의 표준 선질에서는 -10.3%의 오차를 나타냈으며 시험한 모든 RQR 선질에 대해 평균 절대오차는 8.30%±2.85%를 나타내 IEC 60580과 AAPM TG 190의 조건을 만족하였다. 본 연구에서 도출한 공기커마 면적선량계의 교정 방법은 임상에서 사용하는 공기커마 면적 선량계의 간접 교정법으로 사용할 수 있을 것으로 기대한다. According IEC 60601-1 ed3.1 and IEC 60601-2-45 regulation, diagnostic X-ray equipment should be display to measured and calculated air kerma area product. On the clinical X ray equipment, air kerma area product dosimeter would like to have an evidence for dosimeter accuracy and energy dependency. This study was performed to indirect calibration and energy dependency test for attached type air kerma area product (KAP) dosimeter by RQR standards beam quality. On the RQR5 beam quality, attached KAP dosimeter error showed -7.5%, respectably. On the RQR9 beam quality, attached KAP dosimeter error showed -10.4%, respectably. All RQR beam quality, average absolute error was 8.30%±2.85%, respectably. On this study, attached KAP dosimeter was satisfied to IEC 60580 and AAPM TG 190. This calibration method of KAP dosimeter will help to performance maintain for clinical KAP dosimeter.
김정수(Kim Jung Su),이재남(Lee Jae Nam),이기승(Lee Gi Seung),안현준(An Hyun Jun) 한국철도학회 2006 한국철도학회 학술발표대회논문집 Vol.- No.-
The command of Subway is intended to adjust and control the train operation, and to play a key role of the total passenger transport and all kinds of affairs related to the safe train operation. Also, this can be considered as affairs to be controlled and operated by Total Traffic Control. For the purpose of developing the ATO system in using the new control technology by substituting the conventional ATS equipment, this technical document includes the technical points resulted from doing the replacement construction in the entire section of Subway Line 2 by Seoul Metro. The replacement work with the new ATO System should neither stop nor affect the system under operation while operating the current ATS System. The different systems should not interfere with each other while performing their individual affairs, and be composed to share the important data for the parallel operation. This technology is needed to proceed in assurance of a high degree of reliability.