RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 버팀지지대의 선행하중에 따른 흙막이벽의 거동특성

        裵鐘淳,權正烈,權敏載,朴卿局 경상대학교 생산기술연구소 2001 工學硏究院論文集 Vol.1 No.-

        Urban excavation require highly reliable prediction technique for the design and construction of earth retaining structures in order to protect adjacent structures around deep excavation. Application of the pre-loading of bracing for deep excavation has been reported and known beneficial in reducing settlement behind the retaining wall. But this beneficial effects are net fully understood and recognized by many practitioners. Model tests have been carried out to evaluate the efficiency of pre-loading system in reducing ground settlement as well as adjacent structural damages around excavation in sand. The test results revealed that the applied pre-loading of approximately 50% showed effective reduction in the maximum lateral wall displacement and the maximum magnitude of ground surface settlements, Also, bracing forces and earth-pressure distribution behind the wal1 have been monitored during pre-loading at various excavation swages.

      • KCI등재
      • KCI등재후보

        국내 하천 퇴적물 건강성평가를 위한 Microtox 독성시험 조건확립 연구

        정홍배,박정규,문성환,류태권,김소정,배철한,황인영 한국환경독성학회 2001 환경독성보건학회지 Vol.16 No.4

        1. 하천 퇴적물 공극수, 증류수 추출용액 및 유기용매 추출액을 pH6.0~6.5 범위로 조절한 후 Microtox 독성을 측정하는 것이 퇴적물내의 암모니아 독성이 배제된, 유해화학물질 오염에 의한 퇴적물 독성을 평가하는 방안임을 확인하였다. 2. 퇴적물에 대해 공극수, 증류수 추출물, 유기용매 추출물 구분하여 Microtox 독성을 구하는 것이 퇴적물 내 유해화학물질의 독성발현 특성을 예측할 수 있는 기법이라고 사료된다. 3. 조사정점 내 시료 채취 지점간 독성에 편차로 인하여, 동일 정점의 반경 50~100m 내에서 최소 4지점 이상의 퇴적물을 확보하는 것이 해당 정점의 독성 대표값을 산출할 수 있는 방안이 된다고 판단된다. 4. 한강수계인 남한강 지천인 복하천과 양화천, 금강수계인 청주 미호천, 대전 갑천, 낙동강수계인 대구 금호강, 영산강수계인 황룡강 그리고 익산 만경강을 대상으로 한 예비 조사한 결과, 집중연구대상 하천으로의 조건은 금호강이 가장 우수하였다. 5. 하천 퇴적물의 증류수 추출액과 유기용매 추출액의 Microtox 독성값 간의 상호 상관성이 높았다. 그러나, 농축 과정이 용이하므로 정점간 비교를 위한 독성 측정시 유기용매 추출액을 사용하는 것이 바람직하다고 사료되었다. Six rivers were selected as preliminary screening sites to determine the test conditions of Microtox in assessing the toxicity of the sediment. In addition, a pH range of 6.0--6.5 was established in testing pore water, aqueous extracts and organic extracts. Each extractable fraction of sediment showed different toxicities. Therefore, in order to properly examine the toxicity in the sediment, all extractable fractions of sediment samples needed to be tested with Microtox. Thus, sediment samples were additionally collected from at least 4 secondary sites within 50~100 m area of the primary sampling site to reduce any variation or deviation in toxicity assessment. From all sediment toxicity data that was collected from this study, it was concluded that the Keumho river was the most polluted with the highest sediment toxicity of all the rivers analyzed and needed further detailed research on its pollution problem.

      • 하천 수질에 대한 36시간 연속 모니터링 기법 연구

        박정규,정흥배,문성환,류태권,류제영,황인영 한국환경독성학회 2001 환경독성보건학회지 Vol.16 No.4

        1. 금호강물에 대한 상대독성과 수온, 전기전도도의 경우 달서천 내부, 금호강과 달서천의 합류점 하부, 합류점 상부 순으로 값의 크기를 보였고 pH의 경우 역순을 보이므로 달서천이 금호강과 달서천 합류점 하부에 영향을 주는 것으로 사료된다. 2. 금호강 하천수에 대한 Microtox 독성값과 온도, pH, 전기전도도의 상관성은 없었으므로 기존의 일반적인 몇 가지 수질 인자로는 독성변화 및 수준을 판단할 수 없다고 사료된다. 3. 36시간 연속 모니터링을 통해 짧은 시간에도 독성값이 달라지는 것으로 보아 수질의 독성 수준이나 오염 수준을 판단하기 위해서는 연속적인 독성 조사 및 분석이 필요하다고 사료된다. 4. 하천수에 대한 연속 모니터링만으로는 하천 생태 위해도를 평가하기는 어렵다. 따라서, 하천 퇴적물에 대한 특성을 병행하여 조사 분석하는 것이 유해화학물질에 의한 하천 오염을 평가하는 방법이 된다고 사료된다. The main point source of pollution of the Keumho river in Taegu, Korea, stems from waste from the areas of industrial complexes. Although it is widely accepted that pollutants in waste water negatively effects general water quality, it is difficult to evaluate the effluent effect because of varying conditions in ambient water and inconclusive knowledge of causative pollutants. To analyze the water in relation to the industrial effluent in the area, pH, temperature, conductivity, and Microtox toxicity of various river samples were measured. Water samples were collected every 2 hours for 36 hours from Keumho river and Dalseo stream. Data from continuous monitoring for 36 hours showed that effluent in Keumho river originated from Dalseo stream, which is near adjacent to industrial complexes. Change in toxicity and other factors tested during the 36 hours indicated that continuous monitoring was necessary for a satisfactory effluent toxicity test. Furthermore, in addition to water quality monitoring, it was concluded that sediment toxicity also needed to evaluate effluent effects.

      • TFELD 절연층을 위해 ITO glass위에 증착된 (Ba_(0.5),Sr_(0.5))TiO₃박막의 특성

        김정환,배승춘,권성렬,정훈,박진우,김기완 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1

        We have studied that dielectric and electrical properties of (Ba_(0.5),Sr_(0.5))TiO_(3) thin films deposited on Indium Tin Oxide-coated glass substrate by using rf-magnetron sputtering method in this paper. Substrates were heated at room, 300℃ , 400℃, and 500℃. Working pressure was changed 5mTorr, 10mTorr, 20mTorr, 30mTorr respectively substrates temperature, and Ar:O_(2), ratio was fixed 9:1. SEM analysis was conducted to investigate thickness of BST thin films. Dielectric constant, current-voltage(I-V), and transmittance were measured. We observed difference of that thickness, dielectric constant, current-voltage(I-V), and transmittance due to variable substrates temperature and working pressure. We also obtained best conditions at 400℃, 30mTorr. Dielectric constant was 209.1 at 1kHz, leakage current density was below 7.35X10^(-7)A/cm^(2) at 100V, and transmittance was over 91%.

      • MPEG-21 표준의 구현을 위한 Testbed 구축

        손정화,손현식,조영란,권혁민,김만배 강원대학교 정보통신연구소 2003 정보통신논문지 Vol.7 No.-

        1990년대 후반부터 다양한 디지털 통신망을 이용하여 멀티미디어 컨텐츠 서비스가 가능하게 되었다. 하지만, 멀티미디어 컨텐츠의 전달 및 이용을 위한 기반 구조들의 독자적 발전 및 다양한 통합적 관리 체계 시스템으로 인해, 멀티미디어 컨텐츠 표현 방식의 호환성 문제, 혼재하는 네트워크 전달 방식과 단말 방식의 호환성 문제 등의 잠재적인 문제점이 발생한다. 이런 문제의 대안으로 현재 존재하는 기술 및 기반 구조들 사이의 연동을 통한 큰 프레임워크인 MPEG-21이 진행 중이다. 본 논문에서는 현재 표준화 작업이 진행 중인 MPEG-21을 기반으로 하는 Testbed를 제안한다. Testbed는 server, client, DIA(Digital Item Adaptation)의 세 모듈로 구성된다. Server의 역할은 멀티미디어 컨텐츠를 Digital Item(DI)으로 생성하고, client가 DI를 요구할 경우 DIA 모듈을 통해서 변환된 DI를 client에게 제공한다. DIA 모듈은 server에서 동작되며 client로부터 요청된 DI를 분석하고 client로부터 전송된 환경 정보를 이용하여 client 환경에 적합하게 변환된(adapted) DI를 생성하는 것이 주 기능이다. Client는 server에 저장되어 있는 DI를 선택하고 user preference, terminal capability 등의 필요한 정보를 server로 전송한다. Testbed에서는 스포츠 경기의 동영상, 정지 영상, 경기 내용, 역사를 기록한 파일 등의 DI를 이용한다. 표현 언어는 XML이며, HTTP 기반의 Web 환경에서 구동되도록 설계된다.

      • Efavirenz, indinavir, lopinavir, ritonavir의 LC-MS/MS를 이용한 동시 정량법

        채정우,배경진,백인환,서정원,이병요,이은주,남진경,강원구,권광일 충남대학교 약학대학 의약품개발연구소 2009 藥學論文集 Vol.24 No.-

        Efavirenz indinavir and kaleta (co-formulation of lopinavir and ritonavir) are important antiretroviral drugs which have been proved to be human immunodeficiency virus (HIV) protease inhibitors and reduced the morbidity and mortality associated with HIV-1 infection. A brief and fast high performance liquid chromatography coupled with electrospray mass spectrometry (LC-MS/MS, API 4000) method for the determination of 4 anti-retroviral agents (efavirenz, lopinavir, indinavir, ritonavir) in human plasma was developed and validated. A simple protein precipitation method was used on 100μl of human plasma. And internal standard solution (10 ng/ml methaqualone) 1ml and reconstitution solution (MeOH) 1ml were added. After vortexing for 30 s and centrifuging at 13,200rpm for 10min, 2μl of supernatant was injected into the column (XTerra MS C_(18) column, 2.1mm × 50mm 3.5㎛ particle size). The mobile phase consisted of MeOH and 0.1% formic acid in water (80:20 , v/v). The chromatogram was run for 1.5 min at a flow rate of 300μl/min. A triple quadrupole mass spectrometer was operated in a positive ion mode (lopinavir, indinavir, ritonavir) and negative mode (efavirenz), simultaneously and multiple reaction monitoring (MRM) was used for drug quantification. The precursor-to-product ion transitions of m/z 316→69 (efavirenz) and 629→447 (lopinavir) and 614→421 (indinavir) and 721→296 (ritonavir)were used to measure and quantify the analyte. The limit of quantitation (LOQ) was 50 ng/ml (efavirenz, indinavir, ritonavir) and 100 ng/ml (lopinavir). The weighted (l/y²) calibration curve was linear over human plasma range 50∼5000ng/ml (efavirenz), 100∼20000ng/ml (lopinavir), 50∼10000ng/ml (indinavir), 50∼2000ng/ml (ritonavir), correlation coefficient(r²) of 4 antiretroviral agents were higher than 0.998. Accuracies and intra-run precisions ranged within 86.60 and 113.29%, 1.06 and 11.16% for all 4 drugs analysed. This analytical method used to determine these drugs was fast and easy to perform, with minimal sample preparation, and without compromising precision and accuracy. The developed method was successful to determine antiretroviral agents in human plasma, and proved suitable for clinical pharmacokinetic study.

      • KCI등재후보

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼