RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 초고층 아파트의 일조 일조환경 분석에 관한 연구

        임병찬,이상진,김기만 東亞大學校 建設技術硏究所 2007 硏究論文集 Vol.30 No.2

        As the modern city grows larger and larger, overpopulated and over-storied apartments caused violation of its sunlight, view and privacy that became social problems. Especially when after the tower-type block have shown up and the formal type of apartment which is plate-type block had been disappearing ever since. Because of this phenomenon, higher and overcrowded apartment became very common and it even made an apartment which made all the block as tower-type block. As the time goes by, it is very easy to see one person pressing charges against another for his or her right to sunshine nowadays. In this study, we will use Auto-CAD to analyze the sunlight environment of tower-type block apartment for its expected harmful element of sunlight. And we will use this data to present basic data of how sunlight environments effect on buildings when it is being designed as apartment.

      • 평판 디스플레이용 고속 인터페이스 기술 동향 및 전망

        임병찬,권오경,Im, Byeong-Chan,Gwon, O-Gyeong 한국정보디스플레이학회 2002 인포메이션 디스플레이 Vol.3 No.3

        FPD(Flat Panel Display; 평판 디스플레이) 시스템에서의 고속 인터페이스 기술은 적용 범주에 따라 호스트 모듈과 디스플레이 모듈간의 인터페이스와 타이밍 제어기와 구동 LSI 간의 인터페이스로 구분된다 현재까지 발표된 FPD용 인터페이스 기술에는 호스트 모듈과 디스플레이 모듈간의 인터페이스 기술로서 LVDS와 TMDS가 있으며, 타이밍 제어기와 구동 LSI 간의 인터페이스로서 RSDS, Mini-LVDS, CMADS, Whisper Bus 가 있다. 본 고에서는 이러한 기술들의 특징 및 장단점에 대해 논하고, 고속 인터페이스 기술의 향후 전망 및 과제를 제시한다.

      • KCI등재

        비후성 유문 협착증을 동반한 선천성 회장 폐쇄증 1례

        임병찬,이정하,김광식,최국명,신경수,홍정연,김연우,Lim, Byung Chan,Lee, Jung Ha,Kim, Kwang Sig,Choi, Guk Myung,Shin, Kyung Sue,Hong, Jung Yun,Kim, Youn Woo 대한소아청소년과학회 2003 Clinical and Experimental Pediatrics (CEP) Vol.46 No.4

        복부 팽만과 장천공 및 패혈증성 쇼크로 수술 후 진단된 신생아의 회장 폐쇄증에서 비후성 유문 협착증이 동반된 증례로서 회장 폐쇄증의 산전 진단 및 치료 과정에 있어서 다른 부위의 폐쇄증과의 차이를 인지하고, 문합 수술 후 지속적인 구토 증상을 보이는 공회장 폐쇄증 환아에 있어서 수술과 관련된 합병증 이외에 다른 위장관계의 동반 기형의 유무도 확인해야 하며 그 감별 진단에 비후성 유문 협착증도 고려해야 할 것으로 생각된다. Ileal atresia, a subtype of intestinal atresia, is one of the well-recognized causes of bowel obstruction in newborns. Prenatal diagnosis of intestinal atresia is very important in its management and outcome. Unfortunately, there are few cases of ileal atresia diagnosed prenatally, so more appropriate diagnoses and management plans are needed. As an associated gastrointestinal malformation with ileal atresia, hypertrophic pyloric stenosis is rarely reported. We report one case of postnatally diagnosed ileal atresia associated with hypertrophic pyloric stenosis which was complicated initially by bowel perforation and later by vomiting due to pyloric obstruction. Vomiting in the postoperative period is a common problem. But, if vomiting continues after the operation for ileal atresia, hypertrophic pyloric stenosis should be considered as a possible cause of medically retractable non-bilious vomiting.

      • KCI등재

        Ground-Coupled 바닥구조체의 열전달 모델링

        임병찬 대한설비공학회 2004 설비공학 논문집 Vol.16 No.7

        In this paper, a two-dimensional transient ground-coupled numerical model for slab-on-grade foundation is developed and integrated into EnergyPlus. A validation analysis is first presented to ensure that for the developed building foundation heat transfer module is properly implemented within EnergyPlus. Then, the predictions from the developed model are compared to those obtained from the simplified building foundation model currently used in EnergyPlus. The results show that the developed foundation heat transfer module accounts better for the effects of the ground thermal mass attributed to the ground than the simplified foundation model currently used in EnergyPlus.

      • 건축물에서 PCM의 활용가능성에 관한 연구

        임병찬,최형섭,최성호,문광석 東亞大學校 建設技術硏究所 2008 硏究論文集 Vol.31 No.2

        Many technology have been developed to improve an interior environment in buildings for human being, as well Energy saving. Above all things, Energy saving technology with PCM have been used(applied to) for heating and cooling system in buildings and devoted to save Energy. The technology with PCM can improve energy efficiency in a room. Because it can maintain the temperature, storing the energy which was used for heating and cooling in the room. In this study, we analyze the possibility of PCM as Architectural Materials. Appling PCM which uses latent heat to the building, we try to reduce a loss of heat and maximize the effect of energy saving in the building.

      • 사무소건물의 열원방식별 에너지 사용량 및 경제성 분석

        임병찬,김기만 東亞大學校 建設技術硏究所 2006 硏究論文集 Vol.30 No.1

        Energy is required to maintain adequate temperature in a building. In order to maintain indoor temperature properly, energy is necessary. DOE-2.1E, building energy analysis program, was selected for energy consumption simulation for an office building, and BLCC program is used to make an investment related decision based on building life-cycle costs by considering for all project-related costs. Both programs assess the energy efficiency of each thermal equipment, and the LCC evaluation of an office building. The results presented that Ice-Bon thermal storage system is the most efficient plant in this study.

      • 하절기 냉방비용 절감을 위한 구조체 축열성능을 이용한 건물시스템 운전 방안

        임병찬,김기만 東亞大學校 建設技術硏究所 2007 硏究論文集 Vol.31 No.1

        The use of electric power has increased sharply because of the requirement of comfort thermal in cooling system and unusual changes in weather. Especially, it was concentrated some time in a day, so difficult to supply electric power nationwide. And it is required efficient use of electric power. In order to resolve, we have to understand the concept about the thermal storage of structures and the simple knowledge about the electric use and the power rate calculation. And to reduce the maximum electric load and cut down cooling cost, we will find a way to use EnergyPlus program that shows the simulation controlled optimum temperature. 우리나라는 그간 비약적인 경제 성장 및 국민의 생활수준 향상과 더불어 그에 따른 생활 패턴의 변화에 의해 에너지 사용량이 급격히 증가하고 있다. 특히 19세기 이후 인류 산업 문명의 지속적인 개발로 인한 지구 온난화와 기상 이변 그리고 이에 따른 하절기 평균 온도 상승 등의 외부 열 환경 조건은 악화 되어 가는 반면 거주자 생활수준의 향상 및 열 환경에 대한 쾌적성 요구는 증가 하였다. 이러한 현상은 오늘날 건물의 대형화·기밀화 등의 특성과 맞물러 공조 설비의 중요성과 그 규모 확대의 필요성을 부각 시키고 있으며, 이는 실내 요구 조건 충족을 위한 에너지 투입량의 증가 특히 하절기 냉방을 위한 전력 소비량의 급격한 증가라는 결과 를 가져왔다. 실제 한국전력 공사에서 발표한 최근5년간 전력 수급량 표 l 을 비교해 보면 연중 최대 전력 수요가 2000년 41,007MW에서 2004년 51,264MW로 아주 크게 증가하였고 그에 따른 설비용량 또한 47,876MW에서 59,129MW 로 크게 향상된 것을 알수 있다. 또한 우리나라는 4계절에 따른 기온 변화가 뚜렷하여 전력수요도 계절에 따라 변화하고 있는데, 그림 l 에서 볼 수 있듯이 기온이 비교적 온화한 봄·가을철에는 전력수요가 낮고, 기온이 가장 높은 여름철에 최대를 기록한다. 그 중 외기 온도가 최대치를 보이는 특정시간대에 편중되어 국가적 전력수요 관리에 차질을 빚고 있다 실제 시간대별 전력수요를 알아보면 그림 2에서 보는 바와 같이 하루 중 전력수요가 가장 낮은 시간은 새벽 4시 -6시경이며,7시부터 수요가 증가하기 시작하여 12시 에 오전 피크를 이루었다가 점심시간에 일시적인 수요 감소가 생기며 다시 중기-하여 15시경 최대부하를 이룬 전력수요는 17시까지 이루어지다가 한낮의 더위가 점차 누그러지기 시작하는 17시부터 점차 감소한다. 물론 최근 한전 자체에서의 15 시에 집중되는 전력 수요의 최대부하를 낮추기 위한 각종 전력수요관리로 인해 15시에 최대부하가 발생하지 않는 경우도 있다(송귀남 2004).

      • KCI우수등재

        열전소자를 활용한 냉각 제습 장치에 대한 실험적 연구

        임병찬,조성우 대한설비공학회 2019 설비공학 논문집 Vol.31 No.11

        The cooling-dehumidifier unit was developed with the integration of the thermoelectric device with supplying electric power source from the PV system installed outside of a building. The cooling surface of the thermoelectric device is used for cooling and dehumidification of air, The heating surface eliminates the moisture of the rotating dehumidification filter. Thus, the purpose of this study was to investigate experimentally the performance of the developed cooling-dehumidifier unit. Average air temperature was 25.3℃ with average absolute humidity of 0.0122 kg/kg [DA]. After the air passed the cooling-dehumidifier unit the temperature and humidity decreased to 0.8℃ and 0.0019 kg/kg [DA] respectively, with average air temperature of 24.5℃ and average absolute humidity at 0.0103 kg/kg [DA]. The rotating dehumidification filter was examined to investigate the performance of resurrection. The heating surface of thermoelectric device evaporated water contained in the filter and the COP was calculated as 0.11. The result provides a similar pattern to the previous research. 열전소자를 활용한 유닛의 냉방과 제습 성능을 파악하기 위한 실험으로부터 얻은 결론은 아래와 같다. (1) 본 논문에서 제안한 제습 방법으로는 냉각 제습장치와 직접 접촉에 의한 응결과 제습필터를 이용한 흡착방안이며, 열원으로는 PV 모듈 즉 태양광발전을 전원으로 하는 열전소자를 활용하여 냉각 제습 및 회전필터의 재생이 가능하다는 것을 확인하였다. (2) 열전소자가 작동하는 주간의 경우 통과 전․후의 평균 공기 온도는 각각 25.3℃와 24.5℃로 0.8℃로 다소 낮게 나타났고, 절대습도의 평균값은 각각 0.0122 kg/kg[DA]와 0.0103 kg/kg[DA]로 감소하였다. (3) 주간의 통과 전․후 절대 습도량 변화량은 19.4% 감소되는 것으로 나타난 반면, 열전소자가 작동하지 않는 야간에는 11.4%가 증가되는 것으로 나타남에 따라 회전필터는 재생성능을 가진다고 볼 수 있다. (4) 열전소자가 작동되는 주간시간 동안의 유닛의 평균 COP는 0.11로 나타났으나, COP를 향상시키기 위해서는 열전소자 흡열면의 표면온도를 14℃부근 까지 하강시킬 필요가 있는 것으로 나타났다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼