RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • ZnS:Mn AC 박막형 Electroluminescence device의 제작 및 특성조사

        우재룡,김규채,채경락,이상윤 慶北大學校 自然科學大學 1987 自然科學論文集 Vol.5 No.-

        ZnS: Mn thin film electroluminescence device have been fabricated by vacuum evaporation. Phosphor materials were prepared by heat treatment of pure ZnS powder and 0.45wt% quantities of Mn in Argon atmosphere for one hour. Insulator materials were prepared by the same method. These materials were evaporated on the ITO transparent electrode. These films showed electroluminescence phenomenon for AC input power. The brightness was measured as the dependence of applied voltage, the thickness, and the properties of insulator.

      • I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용

        김하균,김수미,우재룡,오소원,이재성,김유경,Kim, Ha Gyun,Kim, Soo Mee,Woo, Jae Ryong,Oh, So Won,Lee, Jae Sung,Kim, Yu Kyeong 대한핵의학기술학회 2014 핵의학 기술 Vol.18 No.1

        치료 후 I-131 SPECT/CT는 잔류 갑상선 위치확인 및 전이유무를 판단하기 위하여 시행된다. 잔류 갑상선에 집적이 심한 경우 영상은 ringing artifact에 의하여 왜곡된다. 본 연구는 ringing artifact를 제거하고 영상의 질을 향상시키기 위한 적절한 post-filter의 적용에 대하여 제시하고자 한다. 본 실험은 hollow sphere와 아크릴통으로 구성된 phantom을 사용하여 SPECT/CT Discovery 670 (GE Healthcare, USA) 장비로 수행하였다. I-131용액을 hollow sphere에 184, 46, 9.2, 2.3 MBq/cc, 아크릴통에 46 kBq/cc을 각각 주입하였고 sphere 대 background의 비를 4000:1, 1000:1, 200:1, 50:1로 설정하였다. 데이터는 다음과 같은 조건으로 획득하였다(HEGP collimator 사용, Attenuation collection 적용, scan time 40 secs/frame, step angle 6도, scan mode non circular, evolution 적용과 미적용). 획득된 데이터는 OSEM (iteration 2, subset 10) 방식으로 재구성하였다. Post-filer의 사용에 따른 이미지의 변화를 보기 위해 3가지의 다른 post-filer들이 사용되었다(butterworth filter cut-off: 0.38, 0.43, 0.48, 0.53, 0.58, hanning filter cut-off: 0.8, 0.85, 0.9, 0.95, 1, gaussian FWHM: 3, 3.4, 4, 4.5, 5). 각각의 데이터는 MRIcro를 사용하여 contrast ratio, background variability를 분석하였고 e.soft ROI tool을 사용하여 FWHM값을 구하였다. Evolution을 적용한 경우, 모든 결과에서 contrast ratio값이 높게 나타났다. Evolution을 적용하지 않은 경우 star artifact 등 왜곡이 발생하였고 영상의 질이 현저히 낮아짐을 확인할 수 있었다. 4000:1, 1000:1, 200:1의 경우, butterworth filter 사용 시 ringing artifact가 발생하였으며 cut-off값이 커질수록 artifact가 감소하였다. Hanning filter를 사용한 경우 ringing artifact는 발생하지 않았다. Contrast ratio와 FWHM값이 butterworth filter나 hanning filter 적용 시 우수하였다. Gaussian filter경우 contrast ratio와 FWHM값에서 저조한 결과를 얻을 수 있었다. 50:1의 경우, 모든 경우에서 ringing artifact가 발생하지 않았다. Butterworth filter를 적용한 경우 가장 높은 contrast ratio와 가장 우수한 FWHM값을 나타내었다. 본 논문을 통하여 I-131 SPECT에서 ringing artifact가 발생 할 경우(thyroid remnant를 포함) hanning filter를 사용하여 영상을 재구성하고, ringing artifact가 발생하지 않을(remnant thyroid를 포함하지 않음) 경우 butterworth filter를 사용하여 재구성하는 것이 바람직하다는 사실을 알 수 있었다. Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

      • 고정용 팁을 사용하는 Automated Liquid-Handling System의 RIA적용의 평가

        신선영,김희선,이현주,장현영,우재룡,이호영,Shin, Sun-Young,Kim, Hee-Sun,Lee, Hyun-Ju,Jang, Hyun-Young,Woo, Jae-Ryong,Lee, Ho-Young 대한핵의학기술학회 2010 핵의학 기술 Vol.14 No.2

        RIA검사에 재생 가능한 고정용 팁이 장착된 Automated Luquid-Handling System을 적용하여 그 사용 가능성을 조사하고, 기존의 single-pipetting과 비교하여multi-pipetting을 이용한 자동분주기의 사용이 검사자의workload를 감소시켜 업무효율을 증가시키는 것을 확인하고자 하는 것이다. Multipipetting을 이용한 자동화장비를 RIA에 적용함으로써 검사 결과의 정확도와 정밀도를 높이고, 검사횟수를 증가시켜 당일진료체계를 구축하여 오늘날의 의료 현장의 요구를 충족 시키고자 한다. 고정된 팁이 장착된 Automated pipettor의 RIA적용 가능성을 조사하기 위하여 분주량의 정확도와 정밀도, 검사결과의 재현성, 일치도, 그리고 검체간 이월오염을 측정하였다. Multi-pipetting을 이용한 자동분주기의 사용이 workload를 감소시키는 것을 시연하기 위하여 daily workload를 20일 동안 측정하였다. Tecan automated pipettor의 정밀도를 측정하였는데, Tecan은 평균 2.1%, 그리고 manual pipettor는 평균 1.6%의 CV를 보였다. Tecan automated pipettor의 재현성을 평가하여 반복 측정된 각각의 그룹에 대한 cpm결과의 평균과 CV를 계산하였는데, HBs Ag 양성 검체는 41,203 cpm과 3.7%의 CV를 보였다. HBs Ag 음성 검체는 99 cpm과 7.9%의 CV를 보였다. 일치도 평가에서는 Tecan automated pipettor 와 Gilson manual pipettor로 분주하여 결과를 분석하였는데, 측정된 결과는 p값이 0.150로 유의한 차가 나타나지 않았고, r값은 0.999로 높은 상관관계를 보였다. 검체간 이월오염은 1 ppm이하임을 확인하였다. 본 연구는 Tecan Freedom evo 100 같은 automated pipetting 장비를 RIA검사에 사용하였을 때, 검사결과의 질을 떨어뜨리지 않으면서 검사의 효율을 향상시킨다는 것을 시연하였다. 자동화장비의 사용은 증가하는 검사건수에 대한 대안이 될 것이며, 검사건수가 증가하더라도 신속하고 정확한 검사결과를 보고 할 수 있게 될 것이다. Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.

      • <sup>99m</sup>Tc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교

        김현,도용호,김재일,최현준,우재룡,박찬록,하태환,Kim, Hyeon,Do, Yong-Ho,Kim, Jae-Il,Choi, Hyeon-Jun,Woo, Jae-Ryong,Bak, Chan-Rok,Ha, Tae-Hwan 대한핵의학기술학회 2020 핵의학 기술 Vol.24 No.1

        사구체 여과율은 신 기능의 평가와 신 질환의 경과 관찰에 중요한 지표다. 현재 임상에서 사구체 여과율을 측정하는 방법은 크게 혈청 크레아티닌 수치와 <sup>99m</sup>Tc-DTPA을 이용해서 계산하는 검사가 유용하게 이용되고 있다. Gates 공식이 발표된 이후, <sup>99m</sup>Tc-DTPA Renal Dynamic Scan 검사시 이를 적용해 GFR을 감마카메라 장비를 이용하여 측정하고 있다. 본 논문의 목적은 Gates 공식을 적용해 사구체 여과율을 측정할 때 동위원소의 용량 변화, Matrix Size 변경에 따른 사구체 여과율을 분석해 보고자 한다. 본원에서 <sup>99m</sup>Tc-DTPA Renal Dynamic Scan 검사를 받은 성인 환자 5명 (환자나이 = 62 ± 5, 남자 3명, 여자 2명)의 결과를 분석하였다. <sup>99m</sup>Tc-DTPA 15 mCi를 환자의 정맥에 순간 주사 후 21분간 동적 영상을 획득하였다. Activity, Matrix Size 변화에 따라 사구체 여과율을 평가하기 위해 2-3분 구간의 양쪽 신장과 조직에 관심 영역을 설정 후 총 계수를 측정하였다. Detector와 Table 간의 거리는 30cm로 유지하였고, 동위원소의 용량 변화 평가를 위해 Pre Syringe(PR)의 용량을 15, 20, 25, 30 mCi로 설정하였고, Post Syringe(PO)의 용량을 1, 5, 10, 15 mCi로 각각 설정하였다. 그리고 각각의 Matrix size를 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, 1024 × 1024로 변경하여 값을 비교 평가하였다. Matrix Size에서 동위원소의 용량이 증가할수록 사구체 여과율의 차이는 최대 52.95%에서 최소 16.67%로 점차 감소하였다. Matrix size 변화에 따른 사구체 여과율 값은 128에서 256, 256에서 512, 512에서 1024로 변경 시 2.4%, 0.2%, 0.2%로 유사하게 나타났으나, 32에서 64, 64에서 128로 변경 시 54.3 %, 39.43%로 GFR 값의 차이가 발생하였다. 마지막으로, 현재 사용 중인 256 Matrix, Pre syringe 15 mCi의 GFR 값을 기준으로 32 Matrix, Pre Syringe 15 mCi, Post Syringe 1 mCi 조건에서 82%로 가장 큰 차이가 발생하였고, 64 Matrix, Pre Syringe 30 mCi, Post Syringe 15 mCi의 조건에서 0.2%로 유사한 결과 값을 나타내었다. 본 논문을 통해 <sup>99m</sup>Tc-DTPA Renal Dynamic Scan에서 Gates 공식을 이용해 사구체 여과율을 측정할 때, 동위원소의 용량과 Matrix Size 변화에 따라 사구체 여과율 측정에 영향이 있음을 확인하였다. 그러므로 각 병원에서 이를 적용해 GFR을 측정할 때 적절한 Parameter를 적용해서 검사의 유용성을 높아야 한다고 생각한다. Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and <sup>99m</sup>Tc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when <sup>99m</sup>Tc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined <sup>99m</sup>Tc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of <sup>99m</sup>Tc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the <sup>99m</sup>Tc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the <sup>99m</sup>Tc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

      • 심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가

        성용준,김태엽,문일상,조성욱,우재룡,Seong, Yong-Joon,Kim, Tae-Yeob,Moon, Il-Sang,Cho, Seong-Wook,Woo, Jae-Ryong 대한핵의학기술학회 2011 핵의학 기술 Vol.15 No.1

        광대역 재구성(wide beam reconstruction, WBR) 기법인 Xpress.cardiac$^{TM}$ 프로그램을 적용하여 기존 OSEM (ordered subsets expectation maximization) 기법과 심근 내 분절별 관류와 국소벽 운동에서의 일치율을 확인하여 WBR 기법의 임상적 유용성을 알아보고자 하였다. 관상동맥질환의 병력이 없고 핵의학 전문의에 의한 판독상 이상소견이 없는 총 20명(남7명, 여자13명: 정상군)과 관상동맥질환을 진단받은 총 10명(남6명, 여자4명: 비정상군)을 대상으로 휴식기 $^{201}Tl$/부하기 $^{99m}Tc$-MIBI 심근관류 SPECT를 실시하였다. 영상 획득과 재구성은 휴식기 시 투사영상당 30초, 곧바로 15초씩 영상을 얻고 부하기 시 투사영상 당 25초, 곧바로 13초씩 영상을 얻어 OSEM과 WBR 기법을 적용하였고 심근 내 분절별 관류과 국소벽 운동은 AutoQuant 프로그램의 QPS/QGS 알고리즘의 20분절 모델을 적용하였다. 관류상태는 5등급(0=정상, 1=경도, 2=중등도, 3=심한 결손, 4=섭취 없음), 국소벽 운동은 5등급(0=정상, 1=경도, 2=중등도, 3=심한운동저하, 4=무운동)으로 분류한 반정량값을 이용해 기존 OSEM 기법과 WBR 기법에서의 일치율을 평가하였다. 정상군에서 기존 OSEM 기법과 WBR 기법에서의 일치율은 휴식기 시 분절별 관류에서 99% (396/400, k=0.662, p<0.0001), 국소벽 운동에서 83.8% (335/400, k=0.283), 부하기 시 분절별 관류에서 95.8% (383/400, k=0.656), 국소벽 운동에서 87.3% (349/400, k=0.390)의 일치율을 보였다. 비정상군에서 휴식기 시 분절별 관류에서 83% (166/200, k=0.605), 국소벽 운동에서 55.5% (111/200, k=0.385), 부하기 시 분절별 관류에서 79.5% (159/200, k=0.682), 국소벽 운동에서 63.5% (127/200, k=0.486)의 일치율을 보였다. 관상동맥 질환의 진단 및 예후 예측에 있어 중요한 의미를 갖는 심근 내 분절별 관류와 국소벽 운동 기능 평가의 지표들을 이용한 WBR 기법은 기존 OSEM 기법과 비교하여 정상 비정상군 모두에서 심근 내 분절별 관류의 일치율은 높았지만 국소벽 운동에서는 의미 있게 낮은 일치율을 보였다. WBR 기법은 높은 해상도와 대조도를 제공할 수 있다고 하나 심근관류 SPECT에서의 적용은 유용성이 떨어진다고 사료된다. Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

      • IRMA 법 Curve에 관하여

        장현영,신선영,이현주,우재룡,이호영,Chang, Hyunyeong,Sin, Sunyoung,Lee, Hyunju,Woo, Jearyong,Lee, Hoyoung 대한핵의학기술학회 2012 핵의학 기술 Vol.16 No.2

        IRMA법의 실험결과 측정 시 각 축의 설정과 곡선 유형에 따라서 값이 다르게 계산되어 나온다. 시약의 안내서에 있는 대로 설정을 하되 안내가 되어 있지 않은 경우에는 안내서의 도표를 참고하여 설정을 하거나. 어려가지 실험을 통해서 가장 최적화된 설정 값을 찾아내야 한다. 본 실험에서 Immunotech사의 TSH에서는 Linear-Logit 값이 가장 좋은값을 나타낸다고 사료된다. 작은 규모의 실험실에서 감마카운터가 고장 시 SR-300을 이용하여 CPM만 측정 후 EXCEL을 이용하여 결과값을 계산 후 보고해도 좋을 것같다. Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.

      • <sup>18</sup>F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법

        권형진,최진욱,이형진,우재룡,김유경,Kwon, Hyeong Jin,Choi, Jin Wook,Lee, Hyeong Jin,Woo, Jae Ryong,Kim, Yoo Kyeong 대한핵의학기술학회 2016 핵의학 기술 Vol.20 No.2

        $^{18}F-Florbetaben$은 베타아밀로이드 병리를 확인하여 인지 장애 및 의심 환자에게 보조적 진단으로 사용되고 있다. 지질 친화성의 특성과 에탄올이 첨가된 약제의 특성상 주사 후 3-way Set에 잔량과 주사 시 환자의 통증이 관심의 대상이 된다. 본 연구는 효과적인 방사성의약품의 주사와 환자 케어 및 우수한 영상을 위함이다. 내원환자 70명을 대상으로 하였고, 환자들에게 평균 $259{\pm}74MBq$의 $^{18}F-FDG$ (20명), $^{18}F-FP-CIT$ (20명), $^{18}F-Florbetaben$ (30명)을 3-way Set으로 주사(Reflusing 2회, Reflusing 3회 이상)를 하여 주사 후 잔량을 측정하였고, $^{18}F-Florbetaben$ 주사 시 사용되는 3-way Set와 Heparin Cap의 효율적인 주사방법을 알아보기 위해서 주사 후 잔량을 측정하여 SPSS 12.0 ANOVA, t-test 통계분석을 통하여 잔량을 비교분석 하였다. 그리고 $^{18}F-Florbetaben$의 통증 유발 성분의 에탄올 양을 측정하기 위하여 Gas Chromatography로 추가 분석을 실시해보았다. Reflusing 2회 시 $^{18}F-FDG$: 1.48 MBq (0.04 mCi), $^{18}F-FP-CIT$: 7.4 MBq (0.2 mCi), $^{18}F-Florbetaben$: 32.6 MBq (0.88 mCi)의 잔량이 측정 되었고 Reflusing 3회 이상 시 $^{18}F-FDG$: 1.85 MBq (0.05 mCi), $^{18}F-FP-CIT$: 3.7 MBq (0.10 mCi), $^{18}F-Florbetaben$: 36.3 MBq(0.98 mCi)의 잔량이 측정 되었다. 다중 비교결과 Reflusing 2회 시 잔량이 유의미한 차이가 있었고(P < 0.05), 3회 이상 시 $^{18}F-Florbetaben$과 $^{18}F-FDG$, $^{18}F-FP-CIT$는 잔량의 유의미한 차이가 있었으며(P < 0.05), $^{18}F-FDG$와 $^{18}F-FP-CIT$는 유의미한 차이가 없었다(P > 0.05). $^{18}F-Florbetaben$ 주사 후 잔량은 3-way Set: 32.6 MBq (0.88 mCi), 36.3 MBq (0.98 mCi)였고 Heparin Cap: 7.03 MBq (0.19 mCi)으로 유의미한 차이가 있었다(P < 0.05). Gas Chromatography 분석결과 에탄올: 207665 ppm, 아세톤: 377.4 ppm으로 나타났다. $^{18}F-Florbetaben$은 $^{18}F-FDG$와 $^{18}F-FP-CIT$에 비해 주사 후 잔량이 많았고, 통증을 유발하는 에탄올 성분의 수치가 높게 나타났다. 주사 시 3-way Set 방식보다는 Heparin Cap을 사용함이 잔량 감소에 더 효과적이었다. 그리고 주사 시 환자의 통증 완화를 위해서 천천히 주사함을 권고한다. Purpose Neuracep is used to other diagnostic evaluations of the brain to estimate beta-amyloid neuritic plaque density in adult patients with cognitive impairment and inspected cognitive impairment. $^{18}F-Florbetaben$ specially has moderate lipophilicity and property of the added ethanol. It is the subject of interest of the patient pain and residual activity after injecting. Our study is effective injection method of the radiopharmaceutical and patient care. So it is for the highest quality image. Materials and Methods Patients were targeted 70 subjects, it was injected mean $259{\pm}74MBq$ to the patients ($^{18}F-FDG$: 20 subjects, $^{18}F-FP-CIT$: 20 subjects, $^{18}F-Florbetaben$: 30 subjects). After injection (reflusing 2 times, reflusing 3 times) using a 3-way set, it measured the residual activity. When injecting $^{18}F-Florbetaben$, we evaluated the effective injection methods(3-way set method and heparin cap method). The average residual activity after the injection was compared using a statistical analysis of SPSS 12.0(ANOVA, t-test analysis). Also, elemental analysis was performed on $^{18}F-Florbetaben$ by GC (Gas Chromatography). Results When reflusing 2 times measured residual activity as follows ($^{18}F-FDG$: 1.48 MBq, $^{18}F-FP-CIT$: 7.4 MBq, $^{18}F-Florbetaben$: 32.6 MBq). And when reflusing 3 times measured residual activity as follows ($^{18}F-FDG$: 1.85 MBq, $^{18}F-FP-CIT$: 3.7 MBq, $^{18}F-Florbetaben$: 36.3 MBq). There was a significant difference when reflusing 2 times(P < 0.05) and reflusing 3 times (P < 0.05). But when reflusing 3 times, there was no significant difference relation FDG and FP-CIT (P > 0.05). $^{18}F-Florbetaben$ Residual activity according to the injection method was a significant difference (P < 0.05). GC analysis results were measured ethanol: 207665 ppm and acceton: 377.4 ppm. Conclusion $^{18}F-Florbetaben$ was high residual activity compared to FDG and FP-CIT. Heparin cap method was effective when $^{18}F-Florbetaben$ was injected. $^{18}F-Florbetaben's$ ethanol component analysis was highly measured. So it is recommended that inject to 6 sec/ml or more in order to reduce the pain.

      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼