RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • HYPER 빔창주위의 열유동 해석에 의한 안전성 평가에 관한 연구

        송민근,최진호,주은선,송태영 경상대학교 생산기술연구소 2000 生産技術硏究所論文集 Vol.16 No.-

        A spent fuel problem has prevented the nuclear power from claiming to be a completely clean energy source. The nuclear transmutation technology to incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(Hybrid Power Extraction Reactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Some major feature of HYPER have been developed and employed. On-power fueling concepts are employed to keep system power constant with minimum variation of accelerator power. A hollow cylinder-type metal fuel is designed for the on-line refueling concept. Lead-bismuth(Pb-Bi) is adopted as a coolant and Spallation target material. One of the issues related to the HYPER target system is the thermal and mechanical loads imposed on the Pb-Bi and the beam window. FLUENT is used for thermal-hydraulic calculation, and finally stress calculation is performed by ANSYS. A beam condition such as current is varied. The initial velocity of Pb-Bi is also varied.

      • KCI등재

        수지상세포의 방사선 저항성에 대한 연구

        김은실,김종순,이명호,범희승,민정준,정환정,김성민,허영준,송호천,이제중 대한핵의학회 2003 핵의학 분자영상 Vol.37 No.3

        목적 : 림프구와 비교되는 수지상 세포의 방사선 민감성을 보기 위하여 본 연구를 시행하였다. 대상 및 방법 : 말초혈액에서 분리한 T 림프구에 0 Gy, 10 Gy, 30 Gy의 방사선을 조사하고 4시간 후에 유세포 분석기를 이용하여 선량별 세포고사 빈도를 관찰하였다. 또한 조혈모세포에서 미성숙 및 성숙 수지상 세포를 단계적으로 분리 배양하여 각각 0 Gy, 10 Gy, 30 Gy, 100 Gy의 방사선을 조사하고 4시간, 24시간 그리고 48 시간 후에 선량별 세포고사 빈도를 관찰하였다. 사이토스핀(cytospin)슬라이드에 림프구와 미성숙 및 성숙 수지상세포를 3×104개 씩 분주하고 May Grunwald-Giemsa 염색한 후, 광학 현미경 하에서 각각의 세포군 당 100개의 세포에서 세포 면적당 핵의 면적 비를 측정하였다. 결과 : 림프구에서는 방사선조사 선량별로 세포고사 빈도가 유의하게 증가하였으나, 수지상 세포에서는 그 분화정도나 방사선조사 선량에 따른 세포고사의 빈도차이가 없었다. 또한 수지상 세포는 방사선선량과 관계없이 용량에 의존적으로 강력한 T-세포 자극능을 보였다. 림프구의 세포에 대한 핵의 면적 비는 미성숙 및 성숙 수지상세포의 세포에 대한 핵의 면적 비보다 현저히 큰 반면, 두 가지 수지상세포간에 유의한 차이는 없었다. 결론 : 수지상세포는 그 분화도와 상관없이 림프구에 비하여 방사선 저항성을 나타내었고, 이는 세포의 형태적 차이에 따른 표적의 크기와 관련이 있을 것으로 생각되며, 향후 분자 생물학적인 연구의 기초 자료로 활용할 수 있을 것으로 생각된다. Purpose : To evaluate radiation sensitivity of dendritic cells in comparison with lymphocytes. Materials and methods : T lymphocytes captured from peripheral blood were irradiated by 0 Gy, 10 Gy, 30Gy. Apoptosis was measured by flowcytometry for staining of Annexin V 4 hours after irradiation. Immature and mature dendritic cells processed from blood hematopoietic stern cell were irradiated by 0 Gy, 10 Gy, 30 Gy, 100 Gy respectively and apoptosis was measured by flowcytometry with time difference as 4h, 24h and 48h after irradiation. Morphometric analysis by percent nucleus was measured in three cell groups, also. Results : Lymphocytes showed radiation sensitivity by increasing apoptotic fraction according to radiation dose. However, both mature and immature dendritic cells showed consistent fraction of apoptosis in spite of increasing radiation dose. Percent nucleus ratio is significantly higher in lymphocytes than that of mature or immature dendritic cells. Stimulation of T-cell by dendritic cells was not changed after irradiation. Conclusion : Dendritic cells showed radioresistance which was associated with small size of nucleus in comparison with lymphocytes and this result would be used as a basal data of radio-labelling for the cellular trafficking studies in nuclear medicine fields.

      • KCI등재

        물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가

        김정철,윤정한,범희승,제갈영종,송호천,민정준,정환정,김성민,허영준,이명호,박영규,정준기 대한핵의학회 2003 핵의학 분자영상 Vol.37 No.2

        목적 : 분화갑상선암 환자에 대한 방사성옥소(I-131) 치료는 재발율과 사망률을 감소시키는 효과적인 치료법이지만, 치료용량을 증가시킴으로써 치료율을 향상시킬 수 있는지에 대해서는 아직 논란이 있다. 본 연구에서는 최대허용선량 치료법의 효용성을 검증하고자 하였다. 대상 및 방법 : 임상적 병기가 제3, 4병기이고, 6개월 이후에 I-131 전신스캔(이하 IWBS)과 혈중 thyroglobulin (이하 Tg), anti-thyroglobulin antibody (이하 ATA), 초음파검사 (이하 US) 및 F-18 FDG PET 등을 통해 치료여부를 확인할 수 있었던 58명(남:여=9:49, 평균연령 50±11세)의 유두상갑상선암 환자를 대상으로 하였다. 이중 11명은 제4병기, 47명은 제3병기였으며, 43명(남:여=4:39), 평균연령 50±11세)은 7.4 GBq 이하의 고식적인 저용량치료법으로 치료하였고, 9.25 GBq 이상의 고용량 치료를 받은 환자는 15명(남:여=5:10, 평균연령 50±12세)으로 고용량군에서 남자가 더 많았으나 연령의 차이는 없었다. 고용량군 환자 모두에서 추적용량의 방사성옥소(평균 77±3 MBq)를 경구 투여한 후 혈중 방사능소실곡선을 통해 최대허용선량(maximum permissible dose, 이하 MPD)을 계산하였으며, 7명에서는 말초혈액림프구의 중기염색체분석법에 의해 생물학적으로 MPD를 계산하였다. 14명에서는 치료용량의 방사성옥소를 투여한 후 혈중 방사능소실곡선을 통해 MPD를 계사하였다. 완전치유(complete response, 이하 CR)는 IWBS에서 병소가 없어지고, 혈중 Tg치가 1 ng/mL 이하로 감소한 경우로 정의하였으며, 부분치유(partial response, 이하 PR)는 IWBS에서 병소가 없어졌더라도 혈중 Tg, ATA치가 높거나, US 또는 PET 검사에서 병소가 남아있는 경우로 정의하였다. 치료후 IWBS에서 병소가 오히려 증가하거나 변함없는 경우는 없었다. 방사성옥소 치료에 의한 부작용은 입원기간 중 타액선이 현저하게 붓고 통증이 있거나, 구토를 심하게 하는 경우, 그리고 퇴원후 1개월째 백혈구수가 20% 이상 감소한 경우로 정의하였다. 결과 : 양 군간에 연속적인 수치변화를 비교하는 경우는 paired t-test를 이용하였으며, 대상군간 치료효과와 부작용의 비교는 chi-square test를 이용하였다. p값 0.05 미만을 통계적으로 유의한 차이로 인정하였다. 고용량군 환자 모두에서 추적용량과 치료용량의 방사성옥소 투여 후 혈액의 피폭선량은 각각 0.012±0.3 Gy, 1.66±25 Gy였으며, 방사성옥소 투여 후 혈액에 전달되는 피폭선량은 추적용량보다 치료용량에서 더 많았고 (1.21: 166 rad, p<0.001), 방사성옥소 1 mCi당 혈액에 전달되는 피폭선량은 차이가 없었다(0.58±0.1 vs. 0.56±0.1 rad/37 MBq, p=0.34). 추적용량 방사성옥소 투여 후 구한 MPD는 평균 13.3±1.9 GBq (9.7 ~ 16 GBq) 이였고, 치료용량 방사성옥소 투여 후 구한 MPD는 평균 13.8±2.1 GBq (10.4 ~ 16.3 GBq)로 유의한 차이가 없었으며 (p=0.20), 두 수치간에는 유의한 상관 관계가 있었다(r=0.8, p<0.0001). 7명의 환자에서 말초혈액림프구 중기염색체 분석법으로 MPD를 측정하였는데 혈액의 피폭선량은 1.78±0.03 G였으며, 같은 환자에서 혈중 방사능소실곡선으로부터 구한 피폭선량은 1.54±0.03 G로 유의하게 낮았으나 (p=0.01), 두 측정치 간에는 유의한 상관관계(r=0.86, p=0.01)가 있었다. 저용량 치료군 43명 중 22명(51.2%)에서 완전치유를 보였고 21명(48.8%)에서는 부분치유를 보인 반면 고용량 치료군 15명 중 12명(80%)에서 완전치유를 보였고 3명(20%)에서만 부분치유를 보여 고용량 치료군에서 유의하게 높은 완전치유를 얻을 수 있었다(p=0.05). 한편 부작용 발생빈도는 저용량 치료군 43명 중 13(30.2%), 고용량 치료군 15명 중 6명(40%)로 양군간에 유의한 차이가 없었다(p=0.46). 임상적인 병기, 연령 및 성별에 따라서는 치유의 차이가 없었다(p>0.05). 결론 : 혈중소실곡선으로부터 MPD를 결정하고 이를 토대로 환자 개개인별로 적절한 선량을 선택하여 치료하는 방법은 부작용을 최소화하면서도 치료효과를 높일 수 있는 매우 유용한 치료법이며, 고위험군 분화갑상선 암 환자에게 가장 적절한 치료법이라고 사료되었다. Purpose: Radioiodine (1-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age 50±11 years) of papillary thyroid cancer. Among them 43 patients were treated with ≤7.4 GBq, while 15 patients with ≥9.25 GBq. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up 1-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were 13.3±1.9 and 13.8±2.1 GBq, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were 1.54±0.03 and 1.78±0.03 Gy (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-does group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose 1-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

      • SCOPUSKCI등재

        Application of Bifurcation Method to a Generalized Modified Boussinesq Equation

        Song, Ming,Yang, Chengxi Department of Mathematics 2009 Kyungpook mathematical journal Vol.49 No.1

        Bifurcation method of dynamical systems is employed to investigate exact solitary wave solutions and kink wave solutions in the generalized modified Boussinesq equation. Under some parameter conditions, their explicit expressions are obtained. Some previous results are extended.

      • Synthesis and Antibacterial Evaluation of (S,Z)-4-methyl-2-(4-oxo-5-((5-substituted phenylfuran-2-yl) methylene)-2-thioxothiazolidin-3-yl)Pentanoic Acids

        Song, Ming-Xia,Deng, Xian-Qing,Wei, Zhi-Yu,Zheng, Chang-Ji,Wu, Yan,An, Chang-Shan,Piao, Hu-Ri Shaheed Beheshti University of Medical Sciences 2015 Iranian journal of pharmaceutical research Vol.14 No.1

        <P>The microbial resistance has become a global hazard with the irrational use of antibiotics. Infection of drug-resistant bacteria seriously threatens human health. Currently, there is an urgent need for the development of novel antimicrobial agents with new mechanisms and lower levels of toxicity. In this paper, a series of (<I>S</I><I>,Z</I>)-4-methyl-2-(4-oxo-5-((5-substitutedphenylfuran-2-yl) methylene)-2-thioxothiazolidin-3-yl)pentanoic acids via a Knoevenagel condensation were synthesized and evaluated for their antibacterial activity <I>in</I><I>-</I><I>vitro</I>. The synthesized compounds were characterized by IR, <SUP>1</SUP>H NMR and MS. The antibacterial test<I> in</I><I>-</I><I>vitro</I> showed that all of the synthesized compounds had good antibacterial activity against several Gram-positive bacteria (including multidrug-resistant clinical isolates) with minimum inhibitory concentration (MIC) values in the range of 2–4 µg/mL. Especially compounds 4c, 4d, 4e and 4f were the most potent, with MIC values of 2 µg/mL against four multidrug-resistant Gram-positive bacterial strains.</P>

      • KCI등재

        Theoretical Study on the Point Defects in N-Doped Anatase TiO2

        Song-You Wang,Fei Pei,Song Wu,Gang Wang,Ming Xu,Liang-Yao Chen,Yu Jia 한국물리학회 2008 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.53 No.4

        In this work, first-principles calculations for the electronic and the optical properties of titanium dioxide (TiO2) with point defects are performed by using a plane wave pseudopotential method in the framework of the density functional theory and the generalized gradient approximation. The point defects, substitutional and interstitial nitrogen, in anatase TiO2 are investigated to understand the origin of the visible-light sensitivity of nitrogen (N)-doped TiO2. The results show that bands originating from substitutional N 2p states appear above the top of the valence band. These states tend to be delocalized and to mix with the valence band as the nitrogen concentration is increased. The optical absorption in the range between 400 and 700 nm is enhanced by the substitutional N impurities. The eect of interstitial N on the electronic and the optical properties of TiO2 depends on the interaction between the nitrogen dopants and the surrounding oxygen. The bonding between N and O introduces a series of localized occupied states under and above the upper valence band, and the electron transitions from these states improve the visible-light absorption of TiO2.

      • KCI등재

        The Characteristics and Distribution of Eukaryotic Phytoplankton Community in Liaodong Bay, China

        Lun Song,Jing Wu,Jing Du,Nan Li,GuangJun Song,Kun Wang,Ming Sun,Peng Wang 한국해양과학기술원 2019 Ocean science journal Vol.54 No.2

        Brown tides have occurred in the Bohai Sea of China since 2009 and caused serious losses in aquaculture. In recent years, phytoplankton identification has been greatly promoted by the development of high-throughput sequencing technologies. In this study, V4 region of 18S rDNA was used as the target gene to design the primer V4 (F/R), and high-throughput sequencing technology was adopted to evaluate the diversity of composition and characteristics of the eukaryotic phytoplankton community. A total of 93 alga species were identified, and about 60% (56 out of 93) of them were undetected or unreported in Chinese waters. There were 59% of the total algal species identified as autotrophy in trophic mode while heterotrophy and mixotrophy accounted for 12% and 29% of the total algal species, respectively. 8 species of picophytoplankton that were mainly distributed in the south and a partial area of the east and west formed the scientific basis for the quality and safety early-warning in aquatic products and brown rides study. Diversity index analysis also revealed a trend of fluctuations of marine phytoplankton diversity in different sample sites in Liaodong Bay. In conclusion, our work provides a detailed evaluation of eukaryotic phytoplankton diversity in Liaodong Bay, suggesting the need for long-term monitoring to further study and guard against the potential risk of harmful algal blooms.

      • SCIESCOPUSKCI등재

        Evaluation of the effect of mechanical deformation on beam isocenter properties of the SC200 scanning beam delivery system

        Wang, Ming,Zheng, Jinxing,Song, Yuntao,Li, Ming,Zeng, Xianhu Korean Nuclear Society 2020 Nuclear Engineering and Technology Vol.52 No.9

        For proton pencil beam scanning (PBS) technology, the accuracy of the dose distribution in a patient is sensitive to the properties of the incident beam. However, mechanical deformation of the proton therapy facility may occur, and this could be an important factor affecting the proton dose distribution in patients. In this paper, we investigated the effect of deformation on an SC200 proton facility's beam isocenter properties. First, mechanical deformation of the PBS nozzle, L-shape plate, and gantry were simulated using a Finite Element code, ANSYS. Then, the impact of the mechanical deformation on the beam's isocenter properties was evaluated using empirical formulas. In addition, we considered the simplest case that could affect the properties of the incident beam (i.e. if only the bending magnet (BG3) has an error in its mounting alignment), and the effect of the beam optics offset on the isocenter characteristics was evaluated. The results showed that the deformation of the beam position in the X and Y direction was less than 0.27 mm, which meets the structural design requirements. Compared to the mechanical deformation of the L-shape plate, the deformation of the gantry had more influence on the beam's isocenter properties. When the error in the mounting alignment of the BG3 is equal to or more than 0.3 mm, the beam deformation at the isocenter exceeds the maximum accepted deformation limits. Generally speaking, for the current design of the SC200 scanning beam delivery system, the effects of mechanical deformation meet the maximum accepted beam deformation limits. In order to further study the effect of the incident beam optics on the isocenter properties, a fine-scale Monte Carlo model including factors relating to the PBS nozzle and the BG3 should be developed in future research.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼