김영인,홍희기,배철호,김영일,윤호식,Kim, Y.I.,Hong, H.K.,Bai, C.H.,Kim, Y.I.,Yoon, H.S. 대한설비공학회 1988 설비저널 Vol.17 No.4
Among several methods to solve the unbalanced electric power load, the Ice Storage System (ISS) for the air conditioning is relatively easy to realize and gives big effect on balancing the electric power load. The goals of this study are to develop the practical ISS for the air conditioning through the design, manufacturing and performance test of the experimental ISS (size $0.335m^3$, cold storage capacity 14200 kcal, IPF 0.4). Thermal fluid motion inside the ice storage tank during cooling storage and cooling release are studied. The data are analyzed by the dispersion analysis and optimal design conditions are derived from the result.
BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석
홍세운,이인복,홍희기,서일환,황현섭,유재인,권경석,하태환,김기성,Hong, S.W.,Lee, I.B.,Hong, H.K.,Seo, I.H.,Hwang, H.S.,Bitog, J.P.,Yoo, J.I.,Kwon, K.S.,Ha, T.H.,Kim, K.S. 한국농공학회 2008 한국농공학회논문집 Vol.50 No.1
Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.
이대영,정성훈,강병하,홍희기,Lee, D.-Y.,Jung, S.-H.,Kang, B.H.,Hong, H. 대한설비공학회 1999 설비공학 논문집 Vol.11 No.1
An experimental study on the performance enhancement of a screw-compressor-type chiller with 100kW of nominal cooling capacity has been carried out. Performance test facility was developed to investigate the effects of a partial modification from the existing chiller on the performance. By replacing the existing shell-and -tube heat exchangers with plate heat exchangers, the cooling capacity is increased by 15~18% and the COP is also increased by 19~21% depending on the operation temperature range. Charging mixed refrigerant R22/R142b(80 : 20) instead of R22 into the chiller with plate heat exchangers improves the cooling capacity by 4% and the COP very largely by 30%. Each contribution of the plate evaporator, plate condenser, and mixed refrigerant to the performance enhancement is examined by analyzing the refrigeration cycle and the heat transfer processes. It is also shown that the chiller performance can be improved by adapting 2-stage-compression cycle using an economizer.