http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
정영림,정탁교,장미옥,김선화,김만구 한국냄새환경학회 2006 실내환경 및 냄새 학회지 Vol.5 No.3
In this study, the TVOCs and odor active compounds emitted from 3 PVC and 5 natural wallpapers were analyzed. The emitted odor intensities and characteristics of the wallpapers were estimated using air dilution sensory and direct olfactory methods. The emissions of TVOCs were measured using the SPME-cryogenic emission test method, which was modified from the RAL-GZ 479 method, which is used in Germany to evaluate the quality of wallpapers. It was found that there was no significant correlation between the emissions of TVOCs and the odor concentration. However, a correlation (0.57) was found between the emitted VOCs and the odor concentration of the low molecular weight compounds, which have strong volatilities, ranging from n-C6 to n-C10. For all 8 wallpapers, vinegar like odor was commonly perceived, with acetic acid identified as the main odor active compound withinthe odor. Benzaldehyde and esters, such as ethyl acrylate and n-butyl acrylate, were identified as odor active compounds, which were expressed as having rubber like smells by the panelists. These results indicate that odor should be included as a domestic regulation for the pollutants emitted from building materials. The identification of odor active compounds emitted from building materials could be useful in the production of eco-environment products. 이 연구에서는 3종의 PVC벽지와 5종의 천연벽지에서 방출되는 TVOCs와 냄새원인물질을 분석해 보았다. 벽지에서 방출되는 냄새강도와 냄새질은 공기희석관능법과 직접관능법으로 측정하였다. TVOCs 방출량은 독일에서 벽지의 품질분석방법으로 사용하고 있는 RAL-GZ 479방법을 변형한 SPME-저온방출시험방법으로 측정하였다. TVOCs와 냄새농도와의 상관성은 거의 없었으나, n-C6~n-C10의 휘발성이 강한 저분자 화합물의 VOCs 방출량과 냄새농도와는 상관성이 0.57로 나타났다. 8종의 벽지에서는 공통적으로 시큼한 냄새가 나타났는데 acetic acid가 주된 냄새원인물질로 확인되었다. 그 외에 고무냄새를 나타낸 화합물로 ethyl acrylate, n-butyl acrylate 등의 에스테르류와 benzaldehyde가 벽지에서 방출되는 것으로 확인되었다. 이 연구결과를 통해 국내에서 시행되고 있는 건축자재 오염물질 방출량 기준에 냄새항목을 추가시켜 규제하는 것이 필요하다고 생각된다. 그리고 건축자재에서 방출되는 냄새의 원인물질의 규명은 친환경제품을 제조하는데 유용하게 활용될 수 있을 것이다.
소형방출챔버를 이용한 방향제의 휘발성 유기화합물 방출특성에 관한 연구
정영림,박현희,오윤희,김순근,손종렬,김선화,유영재,배귀남,김만구,Jung, Young-Rim,Park, Hyun-Hee,Oh, Youn-Hee,Kim, Soon-Geun,Sohn, Jong-Ryeul,Kim, Sun-Hwa,Yu, Young-Jae,Bae, Gwi-Nam,Kim, Man-Goo 대한환경공학회 2011 대한환경공학회지 Vol.33 No.3
소형방출챔버를 이용하여 반응조건(시료량, 온도, 환기횟수)에 따라 방향제에서 방출되는 휘발성 유기화합물의 배출특성을 조사하였다. 시료부하량($1.4{\sim}551.0g/m^2$)에 따라 방향제에서 방출되는 TVOC 방출량은 방출시험 5시간 후 $0.7{\sim}64.4mg/m^2{\cdot}hr$로 나타났다. Limonene, ${\alpha}$-pinene과 linalool 등 방향제에서 방출된 주요 휘발성 유기화합물은 온도와 환기횟수가 클수록 방출량이 증가한 것으로 나타났다. 이들 연구결과는 방향제와 같은 생활용품의 오염물질 방출시험방법 및 방출기준을 정립하기 위한 기초자료로 활용될 것으로 생각된다. This study investigated the emissions characteristics of air freshener using small emission chamber method. The emission of VOCs from air freshener were determined in the small chambers in the temperature (25, $30({\pm}1)^{\circ}C$), relative humidity ($50{\pm}5%$), ventilation rate (0.3, 0.5, ($0.8({\pm}0.005)/hr$), and sample loading factor ($1.4{\sim}551.0g/m^2$) in this study. The emission tests from air freshener for sample loading factor resulted in TVOC emission rates of $0.7{\sim}64.4mg/m^2{\cdot}h$ after 5 hours. For most target VOCs such as limonene, ${\alpha}$-pinene and linalool, higher temperature and ventilation rate levels exhibited increased emission rates.
대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발
정영림,김만구,Jung, Young-Rim,Kim, Man-Goo 한국분석과학회 2001 분석과학 Vol.14 No.5
본 연구에서는 Tenax-GR을 이용한 고체흡착관과 curie-point식 열탈착 장치로 구성된 농축장치와 자동시료채취장치를 short column GC/PID의 주입구에 연결하여 대기압 이하에서 작동되는 자동화된 휴대용 농축-기체 크로마토그래프 시스템을 개발하였다. 이 시스템은 농축-열탈착-분석 및 세정의 3과정이 한 단위로 작동되며 1~2 min 주기로 연속적인 단위조작이 가능하였다. 톨루엔 표준기체로 검토한 농축장치는 $0.405{\sim}4.05mg/m^3$의 농도범위에서 $94.7{\pm}6.6{\sim}103.8{\pm}3.1$의 높은 회수율을 나타냈고, 7% 이내의 RSD로 좋은 재현성을 나타냈다. 4 m의 짧은 모세관 컬럼을 사용한 본 시스템에서는 벤젠, 톨루엔 및 자일렌(BTX)의 혼합표준기체를 30 sec 이내에 신속하게 분리할 수 있었다. 그리고 컬럼출구의 압력이 입구보다 낮은 진공 GC로 작동되기 때문에 일반 GC에 비해 컬럼의 단위길이당 분리능을 높일 수 있었다. 본 시스템의 벤젠, 톨루엔, o-자일렌 표준기체의 검출한계는 각각 41, 49, $472ng/m^3$로 나타났다. 따라서, 본 시스템은 환경대기 중 저농도의 BTX를 수 분 이내의 주기로 연속모니터링하는 장치로 현장에 적용할 수 있을 것이라 생각된다. An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.