http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
농산물 생산 환경에서 분리된 Staphylococcus aureus의 항생제 내성 및 독소 유전자 확인
박수희,김정숙,김경열,정덕화,심원보,Park, Su-Hee,Kim, Jeong-Sook,Kim, Kyeong-Yeol,Chung, Duck-Hwa,Shim, Won-Bo 한국환경보건학회 2013 한국환경보건학회지 Vol.39 No.5
Objectives: This study was undertaken to analyze Staphylococcus aureus from cultivation environments for agricultural products and to confirm antibiotic resistance and enterotoxin genes for the isolated S. aureus. Methods: A total of 648 samples were collected from apple, peach, ginseng and balloon flower farms. S. aureus was isolated from soil, agricultural water, personal hygiene elements (hands, gloves and clothes) and work utensils (boxes). Results: S. aureus was detected in a total of 25 samples and 72 strains were isolated. The resistance rate of the isolated S. aureus strains was confirmed at 33.3%, with 24 resistant strains among the total of 72. Fourteen different patterns types were found, and three pattern types (NV, OX, VA) were confirmed most frequently. As result of the detection of enterotoxin gene type, four gene types (sea: 1, sed: 4, seg: all isolated S. aureus, sei: all isolated S. aureus) were analyzed among a total of nine types. Conclusions: This study demonstrates that personal hygiene techniques should be properly managed, such as washing and sterilization before or after work, because agricultural contamination by S. aureus frequently developed through improper management.
일정 축력을 받는 콘크리트충전 각형 강관기둥의 내화성능 평가
박수희,류재용,정경수,최성모,Park, Su Hee,Ryoo, Jae Yong,Chung, Kyung Soo,Choi, Sung Mo 한국강구조학회 2007 韓國鋼構造學會 論文集 Vol.19 No.6
본 연구에서는 수치해석에 의해 일정 축력을 받는 콘크리트충전 각형강관(각형 CFT) 기둥의 내화성능을 평가하였다. 본 연구에 앞서 각형 CFT 기둥의 실대 내화성능평가 실험을 수행하였으며, 이로써 무내화피복 상태에서 CFT 기둥 자체만의 내화성능을 평가하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 하중비와 기둥단면 직경을 변수로 설정하였다. 수치해석에 의해 예측된 내화성능의 타당성을 검증하기 위하여 실험결과값과 비교 평가해 본 결과, 해석값과 실험값이 서로 잘 일치하거나 해석값이 약간 저평가하고 있음을 확인하였다. 따라서 본 수치해석에 의한 CFT기둥 내화성능 예측은 타당하다고 판단된다. 내화성능 영향인자의 분석 결과, 축력비($N/N_c$)가 동일한 경우 콘크리트 강도가 적을수록 내화성능이 우수하며 단면직경이 클수록 내화성능은 향상되었다. The aim of this research is to evaluate the fire resistance of concrete-filled steel square tube columns (square CFT columns) under constant axial loads by numerical analysis. The authors examined the experimental results on the fire resistance of concrete-filled steel square tube columns without fire protection. As the materials of CFT columns, steel of SPSR 400 grade and concrete of 27.5MPa and 37.8MPa strengths were used. The significant parameters were determined, such as load ratio, cross-sectional dimensions, and concrete strength. Detailed analytical simulations of fire resistance and axial deformation showed good agreement with the experimental observations. Therefore, this numerical analysis exhibited a reasonable estimation of fire resistance of the square CFT column. Results of the numerical parametric studies showed that the fire resistance of the CFT columns increased with the decrease of the concrete strength and the increase of the cross-sectional dimensions about the constant axial load ratio ($N/N_c$).
박수희,이범식,김상연,박성식,배기선,김성덕,Park, Su-Hee,Lee, Bum-Sik,Kim, Sang-Yeon,Park, Seoung-Sik,Bae, Kee-Sun,Kim, Seong-Deok 한국토지주택공사 토지주택연구원 2011 LHI journal of land, housing, and urban affairs Vol.2 No.1
인장을 받는 고강도콘크리트 부재의 정착특성을 평가하고 KCI 2007 정착길이 산정기준의 적용가능성을 평가하기 위하여 콘크리트강도와 정착길이, 섬유혼입률을 변수로 한 정착실험을 수행하였다. 정착실험 수행 결과, 인장을 받는 80MPa의 고강도콘크리트 부재에서 KCI 2007의 최소정착길이의 적용이 가능할 것으로 기대된다. 고강도콘크리트의 내화성능을 확보하기 위하여 혼입되는 섬유(NY+PP)는 0.1%까지 혼입하여도 고강도콘크리트의 정착특성에 영향을 미치지 않는 것으로 나타났다. In this study, development tests varying with concrete strength, development length, and the rate of fiber mix ratio are carried out to evaluate the development characteristics of high-strength concrete member with 80MPa, and the applicability of estimated standards of development length in KCI 2007. As a result, it can be expected that minimum development length of KCI 2007 is applicable to high-strength concrete member with 80MPa. Although the mixed fiber(NY+PP) to secure fire resistance performance of high-strength concrete is included up to 0.1%, it does not affect the development characteristics.
일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가
박수희,송경철,류재용,정경수,최성모,Park, Su Hee,Song, Kyung Chul,Ryoo, Jae Yong,Chung, Kyung Soo,Choi, Sung Mo 한국강구조학회 2008 韓國鋼構造學會 論文集 Vol.20 No.5
In this research, the fire resistance of Concrete-Filled Circular Steel Tube Columns (CFT) was evaluated by numerical analysis. As the materials of CFT columns, the steel of SPSR 400 grade and the concrete of 27.5MPa, 37.8MPa strengths were used. Significant parameters,such as concrete strength, axial load, and cross-sectional dimensions were determined. To verify the accuracy of the numerical analysis,the analysis results were compared with the former experiment results. The effect of the fire resistance time, axial load ratio, cross-sectional dimensions and concrete strength was evaluated by comparison with the fire resistance of the square CFT columns. This research showed that the structural behavior and fire resistance from the findings of numerical parametric studies showed a similarity to that of the experimental results. Therefore, this numerical analysis is reasonable in estimating the fire resistance of the circular CFT column. 본 연구에서는 콘크리트충전 원형강관(원형 CFT)기둥의 내화성능을 평가하기 위하여 수치해석을 수행하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 축력, 단면 직경을 변수로 설정하였다. 수치해석의 정확성을 검증하기 위하여, 기존의 각국 내화성능설계식들에 의한 계산 결과값과 비교 평가 하였다. 또한, 기존의 실대 원형 CFT기둥의 내화성능 평가 실험 결과와 함께 비교 분석하여 수치해석의 타당성을 검증하였다. 원형 CFT기둥의 내화실험 및 수치해석적 연구를 통해 도출된 내화저항시간과 축력비, 단면직경, 콘크리트 강도의 영향을 각형 CFT기둥의 내화성능과 비교 분석하여 각 영향인자들의 영향을 평가하였다. 본 연구의 수치해석적 연구는 실험결과와 비슷한 거동 및 내화성능을 보였다. 따라서 본 연구에서의 수치해석에 의한 CFT기둥의 내화 성능 예측은 타당하다고 판단된다.
박수희 ( Soo Hee Park ),박수정 ( Su Jong Park ),양영애 ( Yeong Ae Yang ) 한국고령친화건강정책학회 2010 대한고령친화산업학회지 Vol.2 No.1
연구목적: 본 연구에서는 장기요양의 작업치료 중재에 대해 검토해보고자 체계적 고찰을 시행하였다. 연구방법: 2000년 1월부터 2009년 10월까지 Pubmed를 통해서 학회지에 게재된 논문을 검색하였다. "long-term care"와 "occupational therapy"를 주요 검색 용어로 사용했다. 연구결과: 8개의 논문이 사용되었으며 분석 결과 높은 수준의 무작위 임상실험 설계를 사용한 RCT(Randomized Controlled Trial) 연구논문은 1개(12.5%)였으며, 디자인 근거수준 다음단계인 대조군 실험 설계를 사용한 CCT(Controled Clinical Trials)는 3개(37.5%), 단일군 실험 설계를 사용한 OD(efficacy study with either a controlled or an other than controlled design)는 4개(50%)였다. 총 8개의 논문에서 장기요양에서 실시되고 있는 작업치료 중재는 9종류였다. 가장 많이 사용된 작업치료 중재는 일상생활동작으로 20%였으며 그 외 삶의 질, 삶의 인식, 인지, 지각, 구강위생교육, 행동치료, 먹기, 음악치료가 실시되었다. 결론: 장기요양의 작업치료 중재는 일상생활동훈련이 가장 많이 사용되고 있었다. 장기요양보험을 통한 작업치료 서비스에 대한 연구는 부족한 편이며, 앞으로 지속적인 연구가 필요할 것이다. Objective: The aim of the present study is to know about occupational therapy of long-term care. Methods: An systematic search in MEDLINE until January 2001 to October 2009 was performed. RCT(Randomized Controlled Trial), CCT(Controled Clinical Trials), OD(efficacy studies with either a controlled or an other than controlled design) and Cohorts designs were included. PubMed databases were searched using key terms relating to "long-term care" and "occupational therapy". Results: 8 studies were included, RCT(n=1) 12.5%, CCT(n=3) 37.5%, and OD(n=4) 50.0% in the review. In the all of included studies, the ADL traing was the biggest part of occupational therapy. The using rate was 20.0% of ADL training, 10.0% of Quality of Life(QOL), perception of life, cognition, perception, oral hygien, behavior control, feeding and music therapy. Conclusion: Although the ADL training is widely used in the result. There was lack of evidence that occupational therapy in long-term care was effective for progress. Future well-designed clinical trials is needed.
콘크리트충전 강관기둥의 내화성능에 대한 국내 구성재료 (강재, 콘크리트)의 고온특성 영향
박수희(Park Su-Hee),송경철(Song Kyung-Chul),정경수(Chung Kyung-Soo),김흥열(Kim Heung-Youl),원용안(Won Yong-Whn),최성모(Choi Sung-Mo) 대한건축학회 2008 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.28 No.1(구조계)
The behaviour of CFT columns exposed to fire is dependent on the thermal and mechanical properties of CFT materials. In this research, the Korean test's thermal properties model of the CFT materials/steel and concrete) is compared with the four model(Eurocode model, AIJ model, T.T. Lie model, J. Yin model) of the outside the country to estimate the thermal properties of the Korea test's model. Using the thermal properties, the numerical analysis was performed to estimate the fire resistance of the CFT structures. We evaluated the actual effect by the thermal and mechanical characteristics of the materials. Through this research, the temperature calculated from test model was overestimated than other models. It is because the thermal diffusivity of domestic concrete test model is the highest. Also, test model was suddenly collapse without sufficient axial deformation. It is because the thermal diffusivity of test model is higher than the other models. And it is because stress-strain curves decreased suddenly after yielding