http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김태훈,유영훈,김형중,안철민,백효채,이두연,김상진,Kim, Tae-Hun,Yu, Yeong-Hun,Kim, Hyeong-Jung,An, Cheol-Min,Baek, Hyo-Chae,Lee, Du-Yeon,Kim, Sang-Jin 대한영상의학회 2003 대한영상의학회지 Vol.49 No.4
Purpose: To elucidate the sequential radiologic manifestations of reperfusion edema after lung transplantation. Materials and Methods: The study group comprised five consecutive lung transplant recipients (M:F=3:2; mean age; 47.5 years) who between July 1996 and April 2002 underwent lung transplantation procedures (four, unilateral; one, bilateral) at our institution. We retrospectively reviewed the serial postoperative radiographs obtained and characterized the lung infiltrates. Results: Lung infiltrates compatible with reperfusion edema were present in all patients (5/5). Reperfusion edema appeared on day 1 in four, and by day 2 in the other. In all transplanted lungs, infiltrates were found in the perihilar and basilar regions, and were scored as maximal on day 1 in one, day 3 in two, day 4 in one and day 5 in the other. Conclusion: The recognition of sequential radiological manifestations helps identify recognition of reperfusion edema after lung transplantation. 목적: 본 연구는 폐이식후 재관류부종의 시기에 따른 방사선적 소견을 기술하려고 한다. 대상과 방법: 본원에서 폐이식을 시행받은 5명의 수여자를 대상으로 하였다. 1996년 7월부터 2002년 3월까지 세 명의 남자와 두 명의 여자가 폐이식을 받았고, 평균 연령은 47.5세 였다. 이 중 4 명은 한쪽 폐만 이식을 받았고, 1명은 양폐 이식을 받았다. 모든 수술후 연속적인 수술후 방사선 사진을 분석하고, 폐음영을 기술 하였다. 결과: 재관류부종은 네 명에서는 수술후 1일째에 , 한 명에서는 2일째에 나타났다. 최대치의 폐음영은 한 명에서 수술후 1일에, 두 명에서 수술후 3일째에, 한 명에서 4일째에, 나머지 한 명은 술후 5일째에 있었다. 결론: 재관류부종은 모든 폐이식 이후에 일어나는 현상이며 방사선학적으로는 폐문주위와 하폐에 우세하게 분포하는 미세 망상형 또는 기강경화로 나타나며, 약 5일 이내에 최대 시기를 거치고 3주 이내에 특별한 치료없이 소실된다.
김태훈,양재호,이재봉,한중석,김성훈,Kim, Tae-Hoon,Yang, Jae-Ho,Lee, Jai-Bong,Han, Jung-Suk,Kim, Sung-Hun 대한치과보철학회 2010 대한치과보철학회지 Vol.48 No.1
연구 목적: 치과용 레진시멘트의 중합 수축은 수복물이 치아에 정확하게 합착되는 것을 방해하고, 내부 응력의 원인이 되어 치아에 여러 문제점을 일으킬 수 있다. 이러한 임상적인 문제점을 줄이기 위해서 사용하는 치과용 레진시멘트의 중합 수축률에 대해 아는 것이 중요하다. 본 연구에서는 상업적으로 이용되고 있는 몇 가지 레진시멘트의 시간에 따른 중합 수축률을 측정, 서로 비교하고자 하였다. 연구 재료 및 방법: 3종류의 자가 중합형 레진시멘트(Fujicem, Superbond, M bond)와 3종류의 이원 중합형 레진시멘트(Maxcem, Panavia F, Variolink II) 별로 각각 5개의 시편을 이용하였다. 각 재료의 중합 수축률은 Bonded disk method를 이용하여 측정하였다. 안쪽 직경 16 mm, 두께 1 mm 의 동으로 제작된 링을 유리판 ($74\;mm\;{\times}\;25\;mm\;{\times}\;3\;mm$) 위의 중앙에 위치시켜 부착하고, 그 유리판 중앙에 실험 재료를 구 형태로 만들어 올리고, 다른 유리판으로 눌러서 원판 형태 (직경 8 mm, 두께 1 mm)의 시편을 제작하였다. 시편의 중합 수축률은 재료가 중합이 시작된 후 120분동안, $23^{\circ}C$에서 측정하였다. 시간에 따른 수축량에 대한 kinetics curve를얻고, 각 실험 재료의 수축률의 평균값 (%)과 표준편차를 구한 뒤, one-way ANOVA 및 Scheffe post hoc test를 유의수준 0.05 에서 처리하여 그 결과 값을 비교하였다. 결과: 1. 실험에 사용된 Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II 은 중합이 시작 된 120 분 후의 중합 수축률이 각각 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90%의 값을 보였다. 2. Panavia F가 중합 수축률이 가장 작았고, Superbond가 중합 수축률이 가장 컸다 (P<.05). 3. Maxcem 과 M Bond 간에는 유의한 차이가 없었다 (P>.05). 4. 6종류의 레진 시멘트에서 90% 이상의 대부분의 수축은 중합이 개시된 30분 내에 거의 일어났다. 결론: 자가 중합형 레진시멘트의 혼합 후 나타나는 중합 수축이 이원 중합형 레진시멘트보다 천천히 일어나지만, 혼합 120분 뒤의 중합 수축은 이원 중합형 레진 시멘트 보다 유의할 정도로 높았다. 치과용 레진시멘트의 중합 수축은 혼합한 후 30 분내에 대부분 일어난다. Purpose: The shrinkage of dental resin cement may cause several clinical problems such as distortion that may jeopardize the accurate fit to the prepared tooth and internal stress within the restorations. It is important to know the polymerization shrinkage-strain of dental resin cement to reduce clinical complications. The purpose of this study was to investigate the polymerization shrinkage-strain kinetics of six commercially available dental resin cements. Material and methods: Three self-cure resin cements (Fujicem, Superbond, M-bond) and three dual-cure resin cements (Maxcem, Panavia-F, Variolink II) were investigated. Time dependent polymerization shrinkage-strain kinetics of the materials were measured by the Bonded-disk method as a function of time at $23^{\circ}C$, with values particularly noted at 1, 5, 10, 30, 60, 120 min after mixing. Five recordings were taken for each materials. The data were analyzed with one-way ANOVA and Scheffe post hoc test at the significance level of 0.05. Results: Polymerization shrinkage-strain values were 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90% for Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II, respectively at 120 minutes after the start of mixing. Panavia F exhibited maximum polymerization shrinkage-strain values, but Superbond showed minimum polymerization shrinkage-strain values among the investigated materials (P < .05). There was no significant differences of shrinkage-strain value between Maxcem and M bond at 120 minutes after the start of mixing (P > .05). Most shrinkage of the resin cement materials investigated occurred in the first 30 minutes after the start of mixing. Conclusion: The onset of polymerization shrinkage of self-cure resin cements was slower than that of dual-cure resin cements after mixing, but the net shrinkage strain values of self-cure resin cements was higher than that of dual-cure resin cements at 120 minutes after mixing. Most shrinkage of the dental resin cements occurred in the first 30 minutes after mixing.
리튬이온 이차전지용 고용량 KVO<sub>3</sub> 음극의 전기화학적 성능개선
김태훈,김경래,박환동,김해빈,류지헌,Kim, Tae Hun,Gim, Gyeong Rae,Park, Hwandong,Kim, Haebeen,Ryu, Ji Heon 한국전기화학회 2019 한국전기화학회지 Vol.22 No.4
바나듐 산화물계 물질은 고용량의 구현이 가능하여 리튬이온 이차전지용 음극재료로 많은 연구가 진행되어 왔다. 본 연구에서는 새로운 음극물질로써 포타슘 메타바나데이트($KVO_3$)를 합성하였으며, 이를 음극 활물질로서의 전기화학적 특성에 대하여 평가하였다. $NH_4VO_3$와 KOH 수용액을 당량에 맞추어 혼합한 후에 이를 가열하여 암모니아를 제거하고 건조함으로써 $KVO_3$ 분말을 손쉽게 합성할 수 있었다. 이렇게 얻어진 $KVO_3$를 300 내지 $500^{\circ}C$에서 8시간 동안 열처리하였다. 열처리 온도가 증가할 수록 초기용량은 감소하였으나, 수명과 효율은 일부 개선되는 경향을 나타내었으나 큰 차이가 나타나지 않았다. 반면에 $KVO_3$를 사용한 전지의 제조 시에 PVdF (polyvinylidene fluoride) 대신에 PAA (polyacrylic acid) 바인더를 사용한 경우 및 전해액 첨가제인 FEC (fluoroethylene carbonate) 를 적용하는 경우에 전기화학적 성능이 크게 개선되었다. 이 전지의 초기 가역용량과 쿨롱효율이 각각 1169 mAh/g과 76.3%로 개선되어 리튬이온 이차전지용 새로운 음극재료로 가능성을 기대할 수 있을 것이다. Vanadium oxide based materials have been studied as novel negative electrode materials in lithium-ion batteries (LIBs) because of their high specific capacity. In this study, potassium metavanadate ($KVO_3$) was synthesized and its electrochemical properties are evaluated as a negative electrode materials. The aqueous solution of $NH_4VO_3$ is mixed with a stoichiometric amount of KOH. The solution is boiled to remove $NH_3$ gas and dried to obtain a precipitate. The obtained $KVO_3$ powders are heat-treated at 300 and $500^{\circ}C$ for 8 h in air. As the heat treatment temperature increases, the initial reversible capacity decreases, but the cycle performance and Coulombic efficiency are improved slightly. On the contrary, the electrochemical performances of the $KVO_3$ electrodes are greatly improved when a polyacrylic acid (PAA) as binder was used instead of polyvinylidene fluoride (PVDF) and a fluoroethylene carbonate (FEC) was used as electrolyte additive. The initial reversible capacity of the $KVO_3$ is 1169 mAh/g and the Coulombic efficiency is improved to 76.3% with moderate cycle performance. The $KVO_3$ has the potential as a novel high-capacity negative electrode materials.
수술 술기: 변경된 비침습적 경피적인 비복근 근막 절제술
김태훈,한승환,Kim, Tae-Hun,Han, Seung-Hwan 대한족부족관절학회 2011 대한족부족관절학회지 Vol.15 No.1
Equinus contracture of the gastrocnemius-soleus complex is associated with many foot and ankle diseases. We introduce a new simple technique that can be performed using a minimal incision with simple devices. Briefly, 0.5 cm sized medial and lateral longitudinal skin incisions are made at the level of the distal one third of the calf. The musculotendinous junction of the gastrocnemius is gently transected using an Arachnoid blade. The skin is, then, closed with non-absorbable sutures.
직물의 물리적 특성에 따른 쾌적성 연구(II) - 직물의 표면특성과 기공특성변화를 중심으로 -
김태훈,전병익,Kim, Tae-Hun,Jeon, Byeong-Ik 한국섬유공학회 1997 한국섬유공학회지 Vol.34 No.10
The purpose of the study was to evaluate the surface and pore characteristics of the wool fabrics. The fabrics used for the study were 100fo wool fabrics woven with variation of weft density, weaving structure, and linear density. Their surface characteristics and mean pore diameter were measured. The results of the study were as follows: 1) Mean Pore diameter (MPD) of the samples increased with decreasing cover factor and weft density, and increasing surface roughness (SMD). It showed that MPD of 30's, single yarn, and plain fabrics were lam or 2) MPD of the samples increased with water vapor transmission rate and air permeability of the samples. 3) Coefficient of friction (MIU) of the samples decreased with increasing bulk dencity and weft density. It showed that MIU of 40's, folded yarn, and satin fabrics were lower In addition, MIU of the samples increased with keeping warmth ratio. 4) SMD of the samples decreased with increasing cover factor and weft density. It showed that SMD of 40's, folded yarn, and satin fabrics were lower. 5) As SMD of the samples increased, there were lots of larger pore in the structure, and thus water vapor transmission rate and air permeability of the samples increased.