http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
전압형 2중 Half-Bridge를 이용한 직렬공진 인버터에 관한 연구
金利國,丁元榮 慶一大學校 1994 論文集 Vol.10 No.1
This paper descrived a study on the series resonant inverter using the Dual-Half Bridge. Voltage control by phase shift involves phasor addition of the outputs of two inverter. This voltage equal to the vector sum of outputs when they are added in-phase. Especially, this inverter system is newly proposed in order to minimize switching losses, low ripple and low noise. A theoretial discussed to the charateristics of the dual inverter circuits.
EIA로 측정한 혈청β-hCG치의 자궁외 임신에 대한 진단적 가치
박윤기,김종욱,이태형,박완석,이승호,정원영 영남대학교 의과대학 1985 Yeungnam University Journal of Medicine Vol.2 No.1
1984년 1울 1일부터 1985년 10월 30일까지 22개월간 영남대학교 의과대학 부속병원 산부인과 자궁외 임신 진단하에 입원하여 수술을 시행받은 환자중, 수술전에 β- hCG 효소면역 측정법에 의해 혈청 hCG치가 측정된 34예의 최종진단 및 수술소견과 뇨 임신반응 검사의 판정결과를 중심으로 혈청 hCG농도를 비교 분석한 결과 다음과 같은 결과를 얻었다. 1. 28예의 난관임신 전예와 계류유산을 동반한 황체파열 1예의 형성 hCG 농도는 59mlU/ml 이상이었으며, 나머지 황체파열 4예와 자궁부속기 농양 1예의 혈청 hCG 농도는 6.6mlU/ml 이하이었다. 2. 난관임신 28예의 혈청 hCG 농도의 분포범위는 59~21, 980 mIU/ml로 22예(78.6%)에서 3,000mlU/ml이하의 혈청 hCG치를 보였으며 100mlU/ml이하의 저농도는 4예(14.3%), 6,500mlU/ml 이상의 고농도는 6예(21.4%)에서 관찰되었다. 3. 난관임신 28예중 복강내 유리혈액이 500ml 이하인 12예와 500ml이상인 16예의 평균 혈청 hCG 농도는 통계적으로 유의성이 있는 차이가 없었다(p>0.05). 4. 파열형 난관임신 15예의 평균 혈청 hCG농도는 비파열형 난관임신 13예의 평균혈청 hCG 농도보다 통계적으로 유의성 있게 높았으나 (P<0.01), 각각의 분포범위에 있어서는 차이가 없었다. 5. 뇨 임신반응 검사의 자궁외 임신에 대한 양성율은 64%(16/25)이었으며, 가음성을 보인 9예 의 평균혈청 hCG 농도와 분포범위는 353mlU/ml와 59~933mlU/ml이었다. 이상의 연구결과로 미루어 보아 뇨 임신반응 검사는 근래 감도가 크게 향상되었음에도 불구하고 자궁외 임신에 대한 진단적 가치의 증대는 없었으며, β- hCG 효소면역 측정법에 의한 단일 혈청 hCG치는 자궁외 임신과 유사한 증상을 나타내는 복강 및 골반질환군에서 자궁외 임신의 진단을 완전히 배제함으로서 자궁외 임신을 조기에 진단할 수는 있으나, 정상 초기임신 및 유산과의 감별진단이나 혈청 hCG치에 따른 자궁외 임신의 평가에는 한계가 있는 것으로 판단되므로, 보다 정확한 진단 및 평가를 위해서는 근래 널리 이용되고 있는 초음파 진단을 병행하 혈청 hCG치를 연속 측정하여 평가하는 방법이 시도 되어야 할 것으로 생각된다. Thirty-four patients with suspected ectopic pregnancy whose serum hCG levels had been measured by beta- hCG EIA before surgery were evaluated retrospectively. The results were as follows: 1. Final diagnosis of thirty-four patients with suspected ectopic pregnancy comprised twenty-eight tubal pregnancy, five ruptures of hemorrhagic corpus luterm and one tubo-overian abscess. One of the five patients with ruptures of hemorrhagic corpus luterm was accompanied by missed abortion. 2. Range of serum hCG levels in twenty-eight patients with tubal pregnancy was 59-21,980mlU/ml and that of four patients with ruptures of hemorrhagic corpus luteum and one patient with tubo-overian abscess was 0.6-6.6 mlU/ml. Serum hCG level of a patient with rupture of hemorrhagic corpus luteum who was accompanied by missed abortion was 200mlU/ml. 3. Serum hCG levels in twenty-two of twenty-eight patients with tubal pregnancy were lower than 3,000 mlU/ml. Low serum hCG level below 100 mlU/ml and high serum hCG level above 6,500mlU/ml were noticed in four and six patients with tubal pregnancy, respectively. 4. Mean serum hCG levels (±SD) of twelve patients with tubal pregnancy who had intraab-dominal free blood of less than 500ml and sixteen patients with tubal pregnancy who had intraabdominal free blood of more than 500ml were 4,131 (±7,801) mlU/ml and 3,208 (±5,081) mlU/ml, respectively. There was no statistical difference in the mean level of serum hCG between both group(P>0.05). 5. Mean serum hCG levels (±SD) of thirteen patients with unruptured tubal pregnancy and fifteen patients with ruptured tubal pregnancy were 2,628(±5,448) mlU/ml and 4,449(±6,938) mlU/ml, respectively. Mean level of serum hCG was statistically higher in ruptured tubal pregnancy(P<0.01). 6. Positive rate of urine pregnancy test in the diagnose of ectopic pregnancy was 64%(16/25) and mean range serum hCG level of nine patients with false negative result were 353 mlU/ml and 59-933 mlU/ml.