http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
펌프 맥동하중에 대한 노심지지배럴 집합체의 음향-구조 연성해석
이장원,문종성,김정규,성기광,김현민,Lee, Jang Won,Moon, Jong Sung,Kim, Jung Gyu,Sung, Ki Kwang,Kim, Hyun Min 대한기계학회 2017 대한기계학회 논문집. Transactions of the KSME. C, 산업기술과 혁신 Vol.5 No.2
The reactor internals shall be secured in safety and structural integrity under various vibrational loading conditions. Thus, U.S. NRC, Regulatory Guide 1.20 requires the evaluation for the reactor internals due to acoustic induced vibration including the response to the reactor coolant pump pressure pulsation. This paper suggests a methodology to develop an analytical model of the core support barrel accounting for the fluid around the structure and to analyze the responses to the pump pulsation loads using acoustic structure interaction analysis. The analysis results were compared with those of US Palo Verde 1 CVAP and showed a good agreement. Thus, it is expected that the suggested methodology could be an efficient way to evaluate the response of the core support barrel to the pump pulsation loads. 원자로내부구조물은 다양한 진동하중조건에서 안전성과 건전성을 유지해야한다. 그러므로 미국원자력규제 위원회는 펌프 압력 맥동에 의한 진동을 포함하여 음향으로 유발되는 진동을 평가하기 위한 규제지침서 1.20을 제시하고 있다. 본 논문은 음향-구조 연성해석 기법을 사용하여 펌프 맥동 가진으로 인한 해석을 위해 노심지지배럴 주변의 유체와 구조의 연성을 고려하여 해석하는 방법론을 제안하였다. 해석결과는 미국 Palo Verde 1호기 종합진동평가 프로그램 발전소 시험결과와 잘 일치한다. 따라서 제안된 해석 방법론은 펌프 압력맥동에 대한 노심지지배럴의 구조응답을 평가하기 위한 효과적 방법으로 판단된다.
김철우(Cheol-Woo Kim),문종성(Jong-Sung Moon),김정규(Jung-Gyu Kim),맹철수(Cheol-Soo Maeng),성기광(Ki Kwang Sung),김현민(Hyun-Min Kim) 대한기계학회 2018 대한기계학회 논문집. Transactions of the KSME. C, 산업기술과 혁신 Vol.6 No.1
상부탑재형 노내계측계통(top-mounted in-core instrumentation, TM-ICI)은 하부탑재형 노내계측계통(bottom mounted in-core instrumentation, BM-ICI)과 달리 원자로 하부 헤드에 관통부가 없고 구조가 단순하기 때문에 중대사고 발생 시 대처 능력을 향상시킬 수 있다. 국내 경수로 원전에서는 하부탑재형 노내계측계통을 채택하고 있기 때문에 중대사고 대응능력 향상을 위해 상부탑재형 노내계측계통 및 연계구조물의 설계를 개발 중에 있다. 본 논문에서는 현재 개발 중에 있는 TM-ICI의 연계 구조물인 원자로 내부구조물에 대한 유한요소 모델을 소개하고 동특성 해석 결과를 제시하였다. 본 논문에서 개발한 모델 및 결과는 다양한 하중에 대한 원자로내부구조물 응답해석에 적용할 수 있으며 상세 설계의 개선에 이용할 수 있을 것으로 기대된다. Since the top mounted in-core instrumentation (TM-ICI) system, which is different from the bottom mounted in-core instrumentation (BM-ICI), has simple configuration without penetration in the reactor lower head, it can improve the abilities to cope with severe accidents. Because domestic light water reactors have BM-ICI, TM-ICI is under development in Korea for improvement of ability to respond to severe accidents. This paper introduces a finite element model of the reactor internals for TM-ICI and its dynamic characteristics. The model and result in this paper are expected to be applied to response analysis for reactor internals of TM-ICI and to be used for improvement of detail design of TM-ICI component.
펌프 맥동하중에 대한 노심지지배럴 집합체의 음향 구조 연성해석
이장원(Jang Won Lee),문종성(Jong Sung Moon),김정규(Jung Gyu Kim),성기광(Ki Kwang Sung),김현민(Hyun Min Kim) 대한기계학회 2016 대한기계학회 춘추학술대회 Vol.2016 No.12
The reactor internals shall be secured in safety and structural integrity under various vibrational load conditions. Thus, U.S. NRC, Regulatory Guide 1.20 requires the evaluation for the reactor internals due to acoustic induced vibration including the response to the reactor coolant pump pressure pulsation. This paper suggests a methodology to develop an analytical model of the core support barrel accounting for the fluid and structures around the core support barrel and to analyze the responses to the pump pulsation loads using acoustic structure interaction analysis. The analysis result was compared to that Palo Verde CVAP and showed a good agreement. Thus, it is expected that the suggested methodology could be more efficient way to evaluate the core support barrel for the pump pulsation loads.
김철우(Cheol Woo Kim),문종성(Jong Sung Moon),김정규(Jung Gyu Kim),맹철수(Cheol Soo Maeng),성기광(Ki Kwang Sung),김현민(Hyun Min Kim) 대한기계학회 2016 대한기계학회 춘추학술대회 Vol.2016 No.12
Since the top mounted in-core instrumentation (TM-ICI) system has abilities to cope with severe accidents for simple configuration and no penetration of the reactor lower head, TM-ICI is under development in Korea. Therefore it needs development of the reactor internals for the TM-ICI. This paper introduces a finite element model of the reactor internals for TM-ICI and its dynamic characteristics for future structural response analyses.
김기유,엄미나,강정복,도영숙,문수경,정일형,손종성,피일선,박은미,김영수,이성봉,조상훈,문선애,Kim, Ki-Yu,Eom, Mi-Na,Kang, Jung-Bok,Do, Young-Suk,Moon, Su-Gyeong,Jung, Il-Hyeong,Son, Jong-Sung,Pi, Il-Seon,Park, Eun-Mi,Kim, Young-Su,Lee, Seong- 한국식품연구원 2008 食品技術 Vol.21 No.2
농산물 중 잔류농약을 보다 쉽고 효율적으로 분석 할 수 있는 다성분 동시분석 방법에 따라서 UPLC-PDA을 이용하여 기기조건에 따른 검출한계 및 정량한계를 식품별 최저 MRL과 비교하여 유효성을 알아보고 회수율을 통하여 방법의 재현성을 조사한 결과 다음과 같다. 41종의 농약에 대한 검량선은 직선성이 우수하였으며 검출한계 $0.005{\sim}0.109mg/kg$으로 나타났으며 정량한계 는 $0.018{\sim}0.363ppm$으로 나타났다. Cycloprothrin 등의 경우처럼 검출기의 감응도가 최저 MRL 기준을 초과하는 농약에 대한 보완으로는 검출감도가보다 우수한 UV 검출기 등의 병행 활용이 필요하다. 회수율에 따른 재현성은 쌀의 경우 첨가 농도 0.4 mg/kg 일때 $62.09{\sim}99.58%$로 편차범위는 $1.03{\sim}13.92%$ 얻을 수 있었다.