RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
          펼치기
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 감마나이프수술 환자의 만족도 및 재원일수에 대한 고찰

        정상순,정현태,백선하,김동규,Jeong, Sang Soon,Chung, Hyun-Tai,Paek, Sun Ha,Kim, Dong Gyu 한국의료질향상학회 2001 한국의료질향상학회지 Vol.8 No.2

        Background : Since a Gamma Knife had been installed on December 1997, 405 patients have been treated until December 1999 at department of neurosurgery of Seoul National University hospital. The authors analyzed results of a work to improve satisfaction of Gamma Knife surgery patients and to reduce hospital length of stay. Methods : To understand main discontent of patients, a pre-survey was performed from October 1998 to December 1999 using a questionnaire. By Analyzing 93 questionnaire received from 234 patients, pain on frame application, explanation before surgery, waiting time before surgery, waiting time before medical procedure were main discontent factor and overall satisfaction ratio was 71.0%. To improve satisfaction ratio, several quality improvement activity works were designed and applied to 123 patients during the period between January 2000 and September 2000. The same questionnaire were analyzed. Works to reduce the patient hospital LOS were devised and applied during the same period. Results : The overall satisfaction ratio of Gamma Knife radiosurgery patients was increased to 83.7%(P=0.10). The main factor to improve satisfaction ratio was to reduce waiting time(P=0.05) and improvement of discomfort during the surgery(P=0.06). The average LOS was reduced from 3.1 to 2.7 days(P=0.003). Conclusion : As a result of quality assurance activities, the overall satisfaction ratio of patients was improved and LOS was reduced. The pain during frame application was remained as a main discontent factor and a further study is required to reduce this pain.

      • KCI우수등재
      • KCI등재후보

        Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery

        최경식,오승종,이정우,김정기,서태석,최보영,김문찬,정현태,Choi Kyoung Sik,Oh Seung Jong,Lee Jeong Woo,Kim Jeung Kee,Suh Tae Suk,Choe Bo Young,Kim Moon Chan,Chung Hyun-Tai Korean Society of Medical Physics 2005 의학물리 Vol.16 No.1

        정위적 방사선 수술은 한 번에 두 개내 병소에는 고선량의 방사선을 조사하면서, 주위 정상조직에는 최소한의 방사선이 조사되도록 시술하는 치료기법이다. 본 연구는 정위적 방사선 수술시 자동적 치료계획을 수행하기 위하여, 선형가속기와 감마나이프의 다수의 회전중심점을 이용하는 치료계획에 대한 물리적 격자구조에 기반한 새로운 방법을 개발하였다. 최적의 방사선 수술계획은 많은 빔관련 변수들의 조합으로서 만들어진다. 본 연구에서는 선형가속기와 감마나이프 수술시 빔 측면도의 50% 수준에서의 선량분포가 콜리메이터/헬멧의 구멍 크기와 일치하는 점을 이용하여 하나의 회전중심점을 중심으로 선량분포를 구형으로 모델화시켰다. 그리고, 다수의 회전중심점들은 병소내 위치와 크기를 고려한 정육면체 구조와 1×1×1 ㎣의 체적소 단위의 계산에 의해 자동적으로 배치시켰다. 이 기법에 의한 치료계획 방법은 선량체적히스토그램, 선량의 일치성, 선량의 균질성의 병소내 선량분포로서 평가되었다. 그 결과, 새로운 기법은 불규칙한 병소들에 대하여 프로그램 시스템에 의해 빠르게 다수의 회전중심점들을 배치시켰다. 또한, RTOG의 권고사항에 언급된 병소내 선량분포의 일치성, 균질성이 기준을 잘 만족하였고, 병소들은 50% 이상의 등선량 곡선 내에 포함되었다. 이와 같은 성과는 불규칙하게 형성된 병소와 선형가속기나 감마나이프와 같은 다른 치료 장치 기법들에서 특별한 제약없이 보편적으로 적용이 될 수 있을 것으로 생각된다. The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

      • KCI등재후보

        감마나이프수술 환자의 만족도 및 재원일수에 대한 고찰

        정상순,정현태,백선하,김동규 한국의료QA학회 2001 한국의료질향상학회지 Vol.8 No.1

        Background : Since a Gamma Knife had been installed on December 1997, 405 patients have been treated until December 1999 at department of neurosurgery of Seoul National University hospital. The authors analyzed results of a work to improve satisfaction of Gamma Knife surgery patients and to reduce hospital length of stay. Methods : To understand main discontent of patients, a pre-survey was performed from October 1998 to December 1999 using a questionnaire. By Analyzing 93 questionnaire received from 234 patients, pain on frame application, explanation before surgery, waiting time before surgery, waiting time before medical procedure were main discontent factor and overall satisfaction ratio was 71.0%. To improve satisfaction ratio, several quality improvement activity works were designed and applied to 123 patients during the period between January 2000 and September 2000. The same questionnaire were analyzed. Works to reduce the patient hospital LOS were devised and applied during the same period. Results : The overall satisfaction ratio of Gamma Knife radiosurgery patients was increased to 83,7%(P=0.10). The main factor to improve satisfaction ratio was to reduce waiting time(P=0.05) and improvement of discomfort during the surgery(P=0.06). The average LOS was reduced from 3.1 to 2.7 days(P=0.003). Conclusion : As a result of quality assurance activities, the overall satisfaction ratio of patients was improved and LOS was reduced. The pain during frame application was remained as a main discontent factor and a further study is required to reduce this pain.

      • SCOPUSSCIEKCI등재

        뇌동맥류 수술환자의 정신신경학적 분석

        정현태,박순필,김상진,도종웅 대한신경외과학회 1987 Journal of Korean neurosurgical society Vol.16 No.4

        The mortality rate of aneurysmal surgery had recently been reduced remarkably due to mordern microsurgical technique and refinement of the timing of operation. Despite recovery without neurological deficits, many patients remain with emotional and psychological sequelae postoperatively. We evaluated 33 patients, operated on intracranial aneurysm for recent 2 years, about quality of life and degree of cognitive function. For proper evaluation of outcome of aneurysmal surgery, in addition to the neurological outcome, psychological aspects must be considered.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼