RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Zephyr 커널에서 고정 시간 동기식 IPC 구현

        정주영,김은영,신동하,Jung, Jooyoung,Kim, Eunyoung,Shin, Dongha 대한임베디드공학회 2017 대한임베디드공학회논문지 Vol.12 No.4

        Linux Foundation has announced a real-time kernel, called Zephyr, for IoT applications recently. Zephyr kernel provides synchronous and asynchronous IPC for data communication between threads. Synchronous IPC is useful for programming multi-threads that need to be executed synchronously, since the sender thread is blocked until the data is delivered to the receiver thread and the completion of data transfer can be known to two threads. In general, 'IPC execution time' is defined as the time duration between the sender thread sends data and the receiver thread receives the data sent. Especially, it is important that 'IPC execution time' in the synchronous IPC should be fixed in real-time kernel like Zephyr. However, we have found that the execution time of the synchronous IPC in Zephyr kernel increases in proportion to the number of threads executing in the kernel. In this paper, we propose a method to implement a fixed time synchronous IPC in Zephyr kernel using Direct Thread Switching(DTS) technique. Using the technique, the receiver thread executes directly after the sender thread sends a data during the remaining time slice of the sender thread and we can archive a fixed IPC execution time even when the number of threads executing in the kernel increases. In this paper, we implemented synchronous IPC using DTS in the Zephyr kernel and found the IPC execution time of the IPC is always 389 cycle that is relatively small and fixed.

      • KCI등재

        붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구

        정주영,윤도군,한성민,장홍석,서태석,Jung, Joo-Young,Yoon, Do-Kun,Han, Seong-Min,Jang, HongSeok,Suh, Tae Suk 한국의학물리학회 2014 의학물리 Vol.25 No.3

        본 연구의 목적은 붕소 중성자 포획 치료 시 집적된 붕소 영역에서 중성자 선속의 변화와 그에 따른 방출된 즉발 감마선의 검출 시뮬레이션을 통하여 치료 영역에 대한 영상화의 가능성을 확인하고자 함이다. 전산 모사를 통하여 (1) 붕소 유무에 따른 중성자의 영향, (2) 내부와 외부에서의 즉발 감마선량 검출, (3) 즉발 감마선에 대한 에너지 스펙트럼 검출을 수행하였다. 모든 전산 모사는 Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA)를 이용하여 가상의 물 팬텀과 열중성자(thermal neutron) 소스, 붕소 영역을 지정하였다. 열중성자의 에너지는 1 eV 이하의 에너지였으며 선속은 2,000,000 n/sec.로 설정하였다. 이 때, 발생된 즉발 감마선의 검출은 물 팬텀과 수직 방향으로 위치시키고 납으로 둘러싸인 lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) 섬광체 검출기를 이용하였다. 붕소가 존재하는 영역인 5 cm 깊이에서의 28 분할로서 대략 0.18 cm의 bin을 도출하여 붕소 영역의 얕은 깊이에서부터 급격하게 저하되는 것을 확인하였다. 또한 붕소 영역이 시작되는 지점인 9 cm 깊이에서 감마선의 피크 레벨을 확인하였다. 그리고 478 keV 지점에서 정확한 즉발 감마선 피크가 관찰되는 것을 확인하였다. 478 keV의 즉발 감마선 피크는 41 keV의 반치폭으로 에너지 분해능 값은 8.5%로 측정되었다. 결론적으로 붕소 중성자 포획 치료 시 발생되는 즉발 감마선의 계측으로 치료가 행해지는 부위를 감마 카메라 또는 단일 광자 방출 단층 촬영 기기에서 영상화할 수 있는 가능성을 확인하였다. The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

      • KCI등재

        몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석

        정주영,윤도군,서태석,Jung, Joo-Young,Yoon, Do-Kun,Suh, Tae-Suk 한국의학물리학회 2013 의학물리 Vol.24 No.4

        본 연구의 목적은 electronic portal imaging device (EPID)를 통하여 방사선 치료를 받는 환자로부터 투과해 나오는 선량으로 외부적인 선량 재구성과 몬테카를로 전산모사로부터 도출되는 내부 선량 계측과의 관계를 도출하고 이를 분석하기 위한 연구로 진행되었다. 본 연구는 전산모사 연구로써 두 가지의 경우를 비교 분석하고 이와 비슷한 연구에 대한 기본적인 지표를 제공하고자 시행되었다. 실험에 관한 기하학적 정보와 방사선 소스에 대한 정보를 몬테카를로 전산모사 툴인 Monte Carlo n-particle (MCNPX)에 입력하였고 EPID 이미지 도출을 위하여 MCNPX 내에 tally카드를 이용하여 선량정보를 도출하고 이를 영상화 할 수 있도록 하였다. 또한 내부적인 계측을 위하여 물 팬텀을 소스와 표면의 거리(source to surface distance, SSD)가 100 cm이 되도록 설정하였으며, 그보다 10 cm 아래에 EPID를 위치시켰다. 내부 계측은 물팬텀 자체에서 흡수되는 흡수 선량을 mesh tally로 수집하였고, 4문 조사를 통하여 중첩된 선량에 대한 데이터를 획득하였다. 그와 동시에 EPID에서 물을 투과해 나오는 선량을 획득 한 뒤 역 투사 방법을 사용하여 선량 재구성을 하였다. 이둘의 경우를 비교하기 위해 자체적인 교정(calibration)을 통하여 투과해 나온 선량과 흡수된 선량과의 관계를 비교하고 4문 조사를 통하여 물 팬텀 내의 특정 부분에 대한 중첩된 선량 데이터와 EPID를 통해 재구성한 선량 데이터를 분석하였다. 물 팬텀과 EPID에서 획득한 누적 선량의 합은 각각 평균 3.4580 MeV/g과 3.4354 MeV/g이었다. 이는 앞서 계측된 물 팬텀 내부의 누적 선량과 0.6536% 선량 오차를 보였다. The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

      • KCI등재

        좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가

        정주영,김민주,정재홍,이스란,서태석,Jung, Joo-Young,Kim, Min-Joo,Jung, Jae-Hong,Lee, Seu-Ran,Suh, Tae-Suk 한국의학물리학회 2013 의학물리 Vol.24 No.4

        방사선 치료를 진행한 오른편 유방암 환자에 비해 왼편 유방암 환자의 방사선 치료 시 왼편 유방의 인접 주요 장기인 심장에 전달되는 선량에 의한 심장 질환의 발병 및 기타 질환의 발병으로 인한 높은 치사율과 관련된 예후가 보고되고 있다. 방사선 치료에서 computed tomography (CT) 영상을 획득 하는 방법 중 deep inspiration breath hold (DIBH) 기법은 들숨 상태에서 일정 시간 동안 환자의 호흡을 정지시키고 영상을 획득 하는 방법으로 심장과 흉곽 사이의 거리가 최대가 되게 한다. 따라서 본 연구에서는 DIBH 영상 획득 기법을 활용하여 왼편 유방암 환자의 방사선 치료 시 DIBH 기법을 적용한 CT 영상을 토대로 심장과 왼편 유방까지의 거리 계산 및 심장에 전달되는 피해 선량을 정량화 함으로써 왼편 유방암 환자의 방사선 치료 시 DIBH 기법의 유용성을 평가하고자 하였다. Free breathing (FB)와 DIBH 기법을 적용한 여성 유방암 환자의 CT 영상을 각 10세트를 획득하고, 50 Gy를 28번으로 분할하여 처방하였으며, 쐐기 필터(wedge filter)를 이용한 대향 2문 접선 조사를 적용했다. 심장과 왼편 유방까지의 거리는 각 장기의 중심 좌표를 획득하고, 각 중심좌표 간의 거리를 계산하였다. DIBH 기법의 경우, 일반적인 FB 기법을 적용 했을 때보다 심장과 왼편 유방 사이의 거리가 평균 1.43 mm 증가하였으며, 통계적 유효성을 확인할 수 있었다. 심장에 전달된 피해 선량의 경우, 최대 선량 기준으로 크게는 3,555 cGy 가량 감소함을 확인할 수 있었다. 각 영상마다의 거리 및 심장의 피해 선량에 대한 정도의 차이는 있었지만, DIBH 기법을 적용하였을 경우, 심장과 왼편 유방까지의 거리의 증가 및 피해 선량 감소 등의 경향성을 확인할 수 있었다. 본 DIBH 기법은 기존 방사선 치료 과정 중 추가적인 시간 소모가 적고, 쉽게 적용할 수 있다는 장점이 있으며, 임상에서의 적용으로 여성 유방암 환자의 불필요한 심장 피해 선량 전달을 감소 시킬 수 있을 것으로 사료된다. Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.

      • KCI등재

        방사선치료계획시스템의 Collapsed Cone Convolution 선량계산 알고리듬을 이용한 빔 모델링의 정확성 평가

        정주영,조웅,김민주,이정우,서태석,Jung, Joo-Young,Cho, Woong,Kim, Min-Joo,Lee, Jeong-Woo,Suh, Tae-Suk 한국의학물리학회 2012 의학물리 Vol.23 No.3

        본 연구의 목적은 국내 개발된 치료계획장치(Treatment Planning System, TPS)인 CorePLAN$^{TM}$에서의 빔 모델링을 기반으로 하는 Collapsed Cone Convolution (CCC) 선량 계산 알고리듬의 정확성을 평가하는 것이다. 여러 셋업 조건에 따라 빔 모델을 TPS에 생성하였고, 6 MV와 15 MV 광자 에너지에 대하여 $50{\times}50{\times}50cm^3$의 물 팬톰 내에서 CCC 알고리듬을 사용하여 선량 계산을 하였다. 대상 조사면은 $4{\times}4cm^2$, $6{\times}6cm^2$, $10{\times}10cm^2$, $20{\times}20cm^2$, $30{\times}30cm^2$와 $40{\times}40cm^2$을 대상으로 하였고, 각각에 대하여 열린 조사면과 쐐기 조사면으로 구분하였다. 생성된 빔 모델들은 측정된 데이터와 계산된 데이터의 심부선량백분율(Percent depth dose, PDD)과 선량프로파일(lateral profile)을 비교하여 모든 깊이에서도 잘 맞는지 평가하였다. 측정된 방사선량과 CorePLAN$^{TM}$에서 CCC 알고리듬을 이용하여 계산된 방사선량은 PDD에 있어 build-up 영역을 제외하고 열린 조사면은 최대 2%, 쐐기 조사면는 최대 3% 이내로 일치하였다. 선량프로파일은 조사면 내 영역에서는 1%, 반음영 영역에서는 4% 이내로 일치함을 확인하였다. 모든 조사면에서 반음영을 제외한 $10{\times}10cm^2$에서 최대 $40{\times}40cm^2$까지의 선량프로파일에 대하여 측정된 방사선량과 계산된 방사선량이 3% 이내로 일치하였다. 반면에, 열린 조사면에 비하여 쐐기 조사면에서 선량 차이가 뿔(horn) 영역의 가장자리에서 4%까지 높게 나타났다. 본 연구 결과에서 보여주는 선량 차이는 일부 영역을 제외하고 국제 기준에 적합한 결과값을 보였다. 선량 차이가 크게 발생하는 영역은 임상적으로 중요성이 크지 않은 표면 영역임을 감안할 때, 임상에서의 활용이 가능하리라 기대된다. This study aims to evaluate the accuracy of the collapsed cone convolution (CCC) algorithm for dose calculation in a treatment planning system (TPS), CorePLAN$^{TM}$. We implemented beam models for various setup conditions in TPS and calculated radiation dose using CCC algorithm for 6 MV and 15 MV photon beam in $50{\times}50{\times}50cm^3$ water phantom. Field sizes were $4{\times}4cm^2$, $6{\times}6cm^2$, $10{\times}10cm^2$, $20{\times}20cm^2$, $30{\times}30cm^2$ and $40{\times}40cm^2$ and each case was classified as open beam cases and wedged beam cases, respectively. Generated beam models were evaluated by comparing calculated data and measured data of percent depth dose (PDD) and lateral profile. As a result, PDD showed good agreement within approximately 2% in open beam cases and 3% in wedged beam cases except for build-up region and lateral profile also correspond within approximately 1% in field and 4% in penumbra region. On the other hand, the discrepancies were found approximately 4% in wedged beam cases. This study has demonstrated the accuracy of beam model-based CCC algorithm in CorePLAN$^{TM}$ and the most of results from this study were acceptable according to international standards. Although, the area with large dose difference shown in this study was not significant region in clinical field, the result of our study would open the possibility to apply CorePLAN$^{TM}$ into clinical field.

      • 최적경로 알고리듬을 활용한 경제적인 통신망 설계 적용 사례

        정주영,최윤수,전철민,조성길,Jung, Ju-Young,Choi, Yun-Soo,Jun, Chul-Min,Cho, Seong-Kil 한국공간정보시스템학회 2006 한국공간정보시스템학회 논문지 Vol.8 No.1

        본 논문에서는 GIS와 네트웍 알고리듬을 이용하여 통신관망의 설계를 최적화하였다. 구체적이고 계량적인 분석을 위해 신규로 조성되는 대규모의 도시개발지역을 대상으로 하여 기존의 설계방식에 의해 산출된 통신관망과 최적경로 알고리듬을 이용한 통신관망과의 건설비용을 비교하였다. 본 연구의 결과 GIS와 최적경로 알고리듬을 적용한 설계 결과가 기존의 설계방법에 비해 상당한 비용절감 효과가 있음을 보여준다. 연구 대상지역에서 기존설계에 의해 산출된 통신관로의 거리는 5,267m이며 최적경로를 적용한 결과는 4,807m로 460m(9.5%)의 차이를 보였다. 결과를 비용으로 산정했을 경우 약 19,469천원(8.7%)의 비용절감 효과를 보였다. 본 연구에서 제시된 최적화 기법은 기존 설계기법에 비해 통신관망의 공사비의 절감 이외에 설계과정의 표준화 및 자동화가 가능하므로 이를 이용한 자동설계 시스템 개발로 설계비용과 인력이동에 따른 설계업무 적응기간 단축과 인건비 절감이 가능하며, 또한 설계 결과에 대한 객관적 검증이 가능할 것으로 판단된다. In this paper, several network algorithms were tested to find an optimal one for telecommunication network design. Algorithms such as Dijkstra's shortest path algorithm, Ford-Bellman's shortest path algorithm, Prim's minimum spanning tree algorithm, and Kruscal's minimum spanning tree algorithm were reviewed and compared in terms of feasibility and resulted network construction cost. Then an optimal algorithm that is most suitable for telecommunication network design was selected. For more specific and quantitative analysis of the selected algorithm, it was implemented to a real telecommunication network construction site. The analyzed results showed that the suggested design method when compared with the conventional one, reduced the network construction cost considerably. The total network length estimated by the conventional method were 5267 meters while the suggested method resulted in 4807 meters. Thus the new method reduced the total network length by 8.7 percent which is equivalent to 97,469,000 Won of construction cost. Considering the frequent telecommunication network constructions, due to new urban developments in the nation, the economic benefit of the suggested telecommunication network design method will be significant. In addition to the construction cost savings, the suggested telecommunication network design procedure possesses several other economic benefits. Since the design procedure can be standardized and automatized, it can reduce the design cost itself and the skill acquirement periods required for new or inapt design crews. Further, due to the standardized and automatized design procedure, any telecommunication network design results can accessed more objectively.

      • KCI등재

        콩팥에서 Erythropoietin 투여로 인한 HSP70의 발현 변화

        정주영,김진,Jung, Ju-Young,Kim, Jin 한국현미경학회 2007 Applied microscopy Vol.37 No.3

        Heat shock protein 70 (HSP70)은 다양한 질병상태와 치명적인 열 손상에서 세포 및 조직을 보호하는데 중요한 역할을 하며, 또한 외부의 stress로부터 세포내 단백질의 파괴와 변화를 감소시키는 단백질로 알려져 있다. 본 연구에서는 오랜 기간 동안 조혈기관의 치료제로 콩팥에서도 세포보호효과가 있는 것으로 알려진 Erythropoietin(EPO)을 투여하여 콩팥내의 HSP70의 발현변화를 세포수준에서 관찰하고자 하였다. Sprague-Dawley계 흰쥐를 사용하여 전자현미경적 면역조직화학법으로 rHuEPO투여군과 대조군에서 HSP70의 발현변화를 관찰하였다. 대조군에서 HSP70은 콩팥의 바깥수질과 속수질에서 관찰되었으며, 특히 속수질에서 강하게 발현되었고 그 부위는 속수질집합관세포와 헨레고리의 내림가는 부분이었다. EPO 투여군에서는 속수질과 바깥수질의 내림가는 부분에서는 발현변화가 관찰되지 않았으나, 바깥수질의 집합관 세포에서 발현이 급격히 증가함을 관찰되었다. 특히 대조군에서의 핵주변부위뿐 아니라 세포내 핵상부분을 비롯한 세포막주변부위에도 강한 면역 염색성을 나타내었다. 이러한 결과는 콩팥의 바깥수질에서 stress성 단백질인 HSP70의 조절기전이 EPO에 의해 매개됨을 보여주면, 세포 stress및 질병상태에서도 이러한 기전이 작용할 것으로 생각된다. Heat shock protein (HSP) 70 functions as a molecular chaperon and reduces stress-induced denaturation and aggregation of intracellular proteins. Erythropoietin (EPO) plays an important role during acute renal failure repair process by rapidly correcting anemia and enhancing renal tubular regeneration. The purpose of this study was to examine the effect of EPO treatment on renal HSP70 expression. Male Sprague-Dawley rats were injected rHUEPO. Kidney were preserved by in vivo perfusion with paraformaldehyde-lysine-periodate (PLP) and processed for immunohistochemistry and electron microscopy. In control kidney, HSP70 was expressed in the cortex, outer medulla and inner medulla. Especially, HSP immunoreactiviy was mainly founded in descending thin limb of outer medulla and inner medullary collecting duct. In EPO treated kidney, HSP70 expression markedly increased in the descending thin limb of outer medulla and newly detected in cortical collecting duct. Electron microscopy showed the presence of HSP immunoreactivity on the intracelluar vesicles and Golgi complex of descending thin limb and cortical collecting duct. These findings suggest that EPO treatment leads to new production of HSP70 in renal tubular cells, and induction of HSP70 by rHuEPO is causally related to protective function.

      • 용접부를 고려한 습분분리기 구조 건전성에 대한 해석적 연구

        정주영(J. Y. Jung),구태완(T. W. Ku),강범수(B. S. Kang) 한국소성가공학회 2011 한국소성가공학회 학술대회 논문집 Vol.2011 No.10

        Moisture separator plays a major role in separating dried steam from moisture. For maintenance and repair of a moisture separator in steam generation used for nuclear power plant, mechanical deformation behavior within welding region is critical in view of the structural integrity. In this study, stress analysis was performed using material property which was obtained by tensile test. Furthermore, the safety factor of the moisture separator is calculated and compared with the allowable strength on each component of the moisture separator. Resultantly, it is confirmed that the safety of the moisture separator under the operating condition.

      • 직접 접촉식 마이크로 점화기의 성능 평가

        정주영(Juyeong Jung),서대반(Daeban Seo),김태규(Taegyu Kim),오현웅(Hyunung Oh),이종광(Jongkwang Lee) 한국추진공학회 2014 한국추진공학회 학술대회논문집 Vol.2014 No.12

        MEMS 추력기를 위한 직접 접촉식 마이크로 점화기를 제안하였다. 제안된 점화기는 Pt/Ti 코일을 유리 박막의 하단에 배치하여 점화 특성을 향상시킬 수 있으며, 유리 박막의 두께를 균일하게 제작할 수 있어 성능 재연성을 향상시킬 수 있다. 직접 접촉식 마이크로 점화기의 성능을 확인해보기 위한 수치 해석을 수행하였다. 코일 표면에서 열유속이 5.66 ㎿/㎡인 경우 기존의 유리 박막 보다 점화 지연이 4.86% 짧아졌으며, 점화 지연은 열유속이 증가함에 따라 지수적으로 감소하는 특성을 보였다. 수치 해석 결과 제안한 점화기가 기존의 점화기에 보다 우수한 점화 성능을 가짐을 확인하였다. Micro igniter using direct contact ignition for MEMS thruster was proposed. The Pt/Ti coil was placed under the glass membrane in order to improve the ignition characteristic. Another merit of the proposed micro igniter is the uniform thickness of the glass membrane to enhance the repeatability. The effectiveness of the micro igniter using direct contact ignition was estimated through a numerical simulation. Ignition delay was 4.86 % shorter than previous micro igniter on the glass-ceramic membrane at the input heat flux of 5.66 ㎿/㎡. The ignition delay and energy exponentially decreased as the input heat flux increased. From the numerical simulation, we confirmed that the ignition characteristics of the proposed micro igniter surpassed that of the previous micro igniter.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼