http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
만성 뇌졸중 환자들의 균형과 보행에 대한 가상현실 피드백의 효과
전재환,안희은,윤태림 한국신경근육물리치료학회(구 한국신경근육재활학회) 2019 한국신경근육재활학회지 Vol.9 No.1
The purpose of this study is to investigate the effect of auditory feedback in virtual reality (VR) walking training on balance and gait functions in chronic stroke patients. Ten chronic stroke hemiplegic patients (age:625, height:167.5, weight:59.7). All subjects underwent three interventions in randomized order: (1) treadmill walking, (2) treadmill walking with virtual reality, (3) treadmill walking with virtual reality and auditory feedback. Outcome measures were he Berg balance scale (BBS), time up-and-go test (TUG), 10-m walk test (10MWT), gait velocity, and paretic side-to-nonparetic side ratio, and measurements were performed before and after the intervention. There was no significant difference in balance and gait (10MWT, TUG, BBS, walking speed, paretic/non-paretic symmetric walking ratio) among the interventions (p>.05). These findings suggest that virtual reality and auditory feedback may not be beneficial for balance and walking in clinical setting. It needs to perform further trials with more robust design.
전통 메주 제조과정에 있어서 근적외 모니터링 가능성 조사
전재환,이선미,조래광 한국식품저장유통학회 2017 한국식품저장유통학회지 Vol.24 No.1
In this study, near infrared (NIR) spectroscopy known as a non-destructive analysis technique was applied to investigate peptide cleavage and consequent release of amino acids in soybean lumps as affected by its moisture content and incubation time during fermentation at 25 for 3 weeks. The NIR spectra of the soybean lump semi-dried and soaked in saline water showed that absorption intensity around 1,400 nm originating from hydrogen bonds of water decreased and absorption band shifted to 1,430 nm as moisture content decreased during incubation at 25 for 3 weeks. In addition, absorption around 2,050 nm which was assigned to amino groups increased as incubation time increased. NIR spectra data from 1,000 to 2,250 nm showed higher accuracy in the discriminant analysis between outside and inside parts of fermented soybean lumps than visible spectra result. NIR spectroscopy for the amino acid and moisture contents in traditional fermented soybean lumps showed relatively good accuracy with the multiple correlation coefficient (R2) of 0.91 and 0.81, respectively, and root mean square error of cross validation (RMSECv) of 0.23 and 0.83%, respectively, in partial least square regression (PLSR). These results indicate that NIR spectral observations could be applicable to control the fermentation process for preparation of soybean products.
조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성
전재환,김병진,이홍재,김진의,김현주,Jeon, Jae-Hwan,Kim, Byeong-Jin,Lee, Hong-Jae,Kim, Jin-Eui,Kim, Hyun-Joo 대한핵의학기술학회 2010 핵의학 기술 Vol.14 No.2
최근 수 년 동안 암 진단의 예민도가 우수한 $^{18}F$-FDG Fusion PET이 건강검진 목적으로 적용되어 왔다. 건강검진에서 $^{18}F$-FDG Fusion PET의 시행 유 무가 조기 암 발견에 유용한지를 규명하기 위하여 건강검진센터에서의 18F-FDG Fusion PET 검사 유 무에 따른 진단율을 비교하였다. 2004년 2월부터 2008년 12월까지 건강검진을 목적으로 서울대학교병원 강남센터를 내원하여 $^{18}F$-FDG Fusion PET을 시행한 2790명을 대상으로 하였다. 피검자에게 $^{18}F$-FDG 5.18 MBq/kg (0.14 mCi/kg)을 투여한 후 1시간이 경과되면 두개골 기저부터 대퇴부까지 영상을 획득하였다. PET scanner는 PHILIPS사의 GEMINI GS를 사용하였다. 서울대학교병원 강남검진센터에서 PET 시행 유 무가 조기 암 진단율에 영향을 주는지에 대하여 분석하였다. 상기 기간 동안 서울대학교병원 강남센터에서 건강검진을 진행한 피검자 중 $^{18}F$-FDG Fusion PET 검사를 시행하지 않은 집단과 시행한 집단은 각각 99,009명과 2,790명이었다. 건강검진에서 PET 검사가 제외된 집단과 시행된 집단의 악성종양 진단율은 각각 0.95%, 1.94%로 나타났다. PET 검사에서 비정상 소견을 보인 사람은 542명이었으며, 이 중 악성 및 양성종양은 각각 10%, 90%로 판명되었다. 악성종양의 종류 및 비율은 갑상선암 31.5%, 폐암 14.8%, 위암 9.3%, 직장암 3.7%, 유방암 3.7%, 전이암 16.7% 등으로 나타났다. 또한 양성 소견으로는 종격동 림프절의 비 특이적인 섭취, 대장의 생리적인 섭취, 갑상선의 미만성 섭취 증가 등이 있었다. 검진 목적으로 시행한 $^{18}F$-FDG Fusion PET의 악성종양 진단율은 일반적인 검진보다 상대적으로 높았다. 결론적으로 건강검진에서 $^{18}F$-FDG Fusion PET을 시행하는 것은 조기 암 진단에 우수하며 유용하다고 사료된다. Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.
잡음에 강인한 초점 값을 이용한 피사체 중심의 자동초점 알고리듬
전재환(Jaehwan Jeon),윤인혜(Inhye Yoon),이진희(Jinhee Lee),백준기(Joonki Paik) 大韓電子工學會 2011 電子工學會論文誌-SP (Signal processing) Vol.48 No.2
본 논문은 잡음에 강인한 초점 값을 이용한 피사체 중심의 자동초점 알고리듬을 제안한다. 제안된 방법은 영상의 엔트로피를 이용하여 피사체가 존재하는 영역을 자동으로 추정함으로써, 배경에 의해 잘못된 자동초점 결과를 얻는 문제점을 개선하였다. 또한 이산 코사인 변환 계수를 분석하여 새로운 초점 값 계산 방법을 제안하였고, 실험결과를 통해 기존의 알고리듬에 비해 제안된 방법이 가우시안 잡음과 임펄스 잡음이 있는 경우에도 초점 값 특성이 강인함을 검증하였다. 제안하는 자동초점 알고리듬은 지능형 감시 시스템의 팬-틸트-줌 카메라 등에 적용 가능하다. In this paper we present subject region-based auto-focusing algorithm using noise robust focus measure. The proposed algorithm automatically estimates the main subject using entropy and solves the traditional problems with a subject position or high frequency component of background image. We also propose a new focus measure by analyzing the discrete cosine transform coefficients. Experimental results show that the proposed method is more robust to Gaussian and impulse noises than the traditional methods. The proposed algorithm can be applied to Pan-tilt-zoom (PTZ) cameras in the intelligent video surveillance system.
UPnP-Zigbee 브릿지 구성 을 통한 임베디드 센서 네트워크에 대한 연구
전재환(Jae-hwan Jun),강성인(Sung-in Kang),김관형(Gwan-hyung Kim),최성욱(Sung-wook Choi),김해영(Hae-Young Kim),오암석(Am-suk Oh) 한국멀티미디어학회 2008 한국멀티미디어학회 학술발표논문집 Vol.2008 No.2
본 논문에서는 최근 의료, 방법, 관재 등의 다양한 활용 시스템에서 중요성이 부각되는 USN 환경을 기반으로 다양한 센서 장치를 활용하며 이러한 센서 장치들의 네트워크 구성을 표준화된 연결성과 효율적인 장치관리를 제공할 수 있는 UPnP 통합 네트워크로 구성하고자 한다. 통합 네트워크 연결 확인을 위하여 PSOC를 활용한 소형화핀 센서 모듈 구성을 바탕으로 Zigbee 기반의 착용형 무선 생체 데이터 취득 센서, 사용자 상황 인식을 위한 환경 데이터 취득 센서를 설계 구현하였다. 그리고 이러한 Zigbee 기반의 임베디드 센서 장치의 UPnP 장치화를 위하여 UPnP-Zigbee 브릿지를 구성 하였다.