http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김종혁,김일해,박만진,장동영,한동철,백영종 한국공작기계학회 2004 한국공작기계학회 춘계학술대회논문집 Vol.2004 No.-
General purpose of cylindrical capacitive displacement sensor(CCS) is measuring run-out motion and deflection of rotor. If CCS has narrow sensing range, its sensitivity coefficients must be calibrated precisely. And x, y component of CCS output can be coupled. In this research, CCS calibration procedure is automated with automatic calibration program and PC-controlled stage. And, coupled-terms of CCS signals were removed and the errors between measured position and mapped CCS signal were reduced obviously by sensitivity matrix that linearly
이장훈,권혁구,박승호,김동진,홍철호 한국환경독성학회 2004 환경독성보건학회지 Vol.19 No.2
Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs(Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for real time environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene(BTX). Also, it can be used as a stand-alone type and/or fixed type in the vehicle with rack for real-time environmental monitoring.
Si Bulk Micromachining을 위한 Wafer Rolling Etching 및 그 특성
김건년,이보나,박효덕,신상모,공경준,장동근,김병철,권혁채,이봉희 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
A wafer rolling etching system for the silicon bulk micromachining has been designed and fabricated. The silicon diaphragms were anisotropically etched in a 24.5 weight percent KOH solution. Compared to the conventional KOH etching systems, pyramidal hillocks, and wave-shaped structures on the etched surfaces were greatly reduced by using this system. After etching for time of 438 minutes, the average etched depth and the etch-rate were measured to be 537μm and 1.22μm/min, respectively. The average etching uniformity of etching depth was 0.87% in 5-inch wafer. Our results showed that the wafer rolling method enhanced etch uniformity and etch rate.
고혈압(高血壓) 뇌졸중(腦卒中) 환자(患者)에 대한 사혈(瀉血)의 강압효과(降壓效果)
문장혁,안호진,정동화,윤형선,장재원,김경선,문익렬,백종엽,이상무,Mon, Jang-hyuk,Ahn, Ho-jin,Jeong, Dong-hwa,Yoon, Hyung-sun,Jang, Jae-won,Kim, Kyung-sun,Moon, Ik-ryoul,Baek, Jong-yeob,Lee, Sang-moo 대한침구의학회 2003 대한침구의학회지 Vol.20 No.2
Objective : The aim of this research was to investigate the depressive effect of depletion of B15(心兪), B23(腎兪), L5(尺澤), B40(委中) in hypertentive stroke patients. Methods : Depletion on B15(心兪), B23(腎兪), L5(尺澤), B40(委中) in hypertentive stroke patient who were admitted in Dong-Seo Oriental Medical Hospital every other day form 4 weeks, without western antihypertensive drug. Results : After treatment in 2nd week, depletion on B15(心兪), B23(腎兪), L5(尺澤), B40(委中) without western antihypertensive drug increased the systolic and diastolic blood pressure. After treatment in 4th week, depletion on B15(心兪), B23(腎兪), L5(尺澤), B40(委中) without western antihypertensive drug decreased the systolic and diastolic blood pressure. After treatment in 4th week, values of RBC and hemoglobine were not significantly changed. Conclusions : Continous depletion on B15(心兪), B23(腎兪), L5(尺澤), B40(委中) in hypertentive stroke patient without western antihypertensive drug implies decreasement of blood pressure, without change of values of RBC and hemoglobine.
Fusarisetin A, an Acinar Morphogenesis Inhibitor from a Soil Fungus, Fusarium sp. FN080326
Jang, Jae-Hyuk,Asami, Yukihiro,Jang, Jun-Pil,Kim, Sun-Ok,Moon, Dong Oh,Shin, Kee-Sun,Hashizume, Daisuke,Muroi, Makoto,Saito, Tamio,Oh, Hyuncheol,Kim, Bo Yeon,Osada, Hiroyuki,Ahn, Jong Seog American Chemical Society 2011 JOURNAL OF THE AMERICAN CHEMICAL SOCIETY - Vol.133 No.18
<P>An acinar morphogenesis inhibitor named fusarisetin A (<B>1</B>) that possesses both an unprecedented carbon skeleton and a new pentacyclic ring system has been identified from an in-house fractionated fungal library using a three-dimensional matrigel-induced acinar morphogenesis assay system. The structure of <B>1</B> was determined in detail by NMR and circular dichroism spectroscopy, X-ray analysis, and chemical reaction experiments.</P><P><B>Graphic Abstract</B> <IMG SRC='http://pubs.acs.org/appl/literatum/publisher/achs/journals/content/jacsat/2011/jacsat.2011.133.issue-18/ja1110688/production/images/medium/ja-2010-110688_0005.gif'></P><P><A href='http://pubs.acs.org/doi/suppl/10.1021/ja1110688'>ACS Electronic Supporting Info</A></P>
돌발성 감각신경성 난청 환자에서 비디오 두부충동검사로 확인된 재고정 신속안구운동
Dong Hyuk Jang,Sun Seong Kang,Hyun Joon Shim,Yong-Hwi An 대한평형의학회 2023 Research in Vestibular Science Vol.22 No.2
Objectives: This study was performed to evaluate characteristics and their prognostic value of video-head impulse test (vHIT) in sudden sensorineural hearing loss (SSNHL) with vertigo. Methods: Of the 612 patients with a diagnosis of SSNHL from 2010 to 2018, 110 patients (18.0%) with vertigo and 39 patients (6.4%) with vHIT results were recruited. The patients were evaluated for their pure-tone hearing average (at initial, 1-month, and 6-month visit), the presence of re-fixation saccade and gains at vHIT, the canal paresis (CP) at ccaloric test. Results: Patients with saccade (+) showed higher pure-tone averages than those with saccade (‒) on initial and follow-up audiograms. The improvement in puretone averages was less in the saccade (+) group than in the saccade (‒) group. There was no significant difference of hearing recovery between SSNHL patients with normal gain and those with decreased gain. There was no difference of hearing improvement between CP (+) and CP (‒) groups according to the presence of re-fixation saccade. Conclusions: Concurrent re-fixation saccade at vHIT is a negative prognostic factor of hearing function in SSNHL. Re-fixation saccade in SSNHL may suggest widespread damages to both the cochlea and the vestibule, leading to the poor prognosis.