http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
방사선 치료에 따른 99mTc - pertechnetate를 이용한 이하선과 악하선 기능 검사의 유용성
홍인수(In Soo Hong),성기준(Ki Joon Sung),김명순(Myung Soon Kim),김종진(Jong Jin Kim),이종영(Jong Young Lee),박진숙(Jin Sook Park) 대한핵의학회 1996 핵의학 분자영상 Vol.30 No.3
N/A Purpose: To assess the functional change of salivary gland, recovery of salivary destruction, difference of susceptibility to irradiation between the parotid and submandibular gland, correlation between the xerostomia and excretory rate by irradiation in salivary Tc-99m-pertechnetate in patients with head and neck cancer. Materials and Methods: We evaluated 19 patients with head and neck cancer who Tc-99m-pertechnetate salivary gland scan before, during and after radiotherapy. We measured the uptake of radioactivity every 5 minutes for 60 minutes after injection of Tc-99m-pertechnetate(370MBq). We also evaluated the first excretory function stimulated by 5% citric acid at 30 minutes after injection of Tc-99m-pertechnetate and then the second excretory function stimulated by 10% citric acid at 45 minutes. Results: The mean uptake curves showed a sharp increase at the 1st week of radiotherapy and then showed a gradual decrease afterwards during radiotherapy. And the mean uptake curves after radiotherapy persistently decreased on follow up scans without being recovered. The excretory rates decreased gradually as radiation dose increased and were not recovered after radiotherapy. Our study was not satisfactory enough to show the difference of susceptibility to irradiation between the parotid and salivary gland and the correlation between the symptom of xerostomia and the change of the excretory rates. Conclusion: The parotid and submandibular gland scans using Tc-99m- perechnetate are useful in the assessment of the functional change of the salivary gland by radiotherapy and predicted the functional change of the salivary gland until 1 year-follow up scan. KW: Salivary gland abnormality, Salivary gland, radionuclide studies, Salivary gland, therapeutic radiology, Tc-99m-pertechnetate
지훈,조휘율,김영주,홍인수,김명순,성기준,Ji, Hoon,Cho, Whi-Youl,Kim, Young-Ju,Hong, In-Soo,Kim, Myung-Soon,Sung, Ki-Joon 대한영상의학회 1992 대한영상의학회지 Vol.28 No.5
An echogenic lobulated round mass in the head of pancreas was found during abdominal ultrasonography for routine on a 34 vear-old man. CT and MRI showed characteristic findings of lipoma. Clinical followup confirmed intrapnacreatic lipoma, which had been reported only once proviously. This lesion should be added to list of benign connective tissue tumor of the pancreas.
한영 혼용 문서에서의 효과적인 문자 분할을 위한 언어 인식에 관한 연구
최원효(Won-Hyo Choi),양병석(Byoung-Seok Yang),성기준(Ki-Joon Sung),강재우(Jae-Woo Kang),하진영(Jin-Young Ha) 한국정보과학회 2008 한국정보과학회 학술발표논문집 Vol.35 No.1
본 논문은 한영 혼용 문서에서의 문자 분할을 위한 효율적인 언어 인식기를 고안하였다. 한영 혼용 문서를 스캔한 후, OCR(광학 문자 판독, Optical Character Recognition)을 할 때, 문자 분할의 중요성은 상당히 크다. 인식 없이 문자를 분할하는 external segmentation 방법에서는, 인식할 언어가 한글 혹은 영어인가에 따라 문자 분할 방법이 달라진다. 그러므로, 한영 혼용 이미지를 인식하기 위해서 문자 분할을 하기 전에 언어를 미리 결정해야 한다. 본 논문에서는 문자 분할 방법을 효율적으로 하기 위한 언어 인식기를 제안하고 그 방법을 적용하였다. 그 결과 한영 혼용된 책 이미지에서 94.09%의 문자 분할 성공률을 보였다.
Thermal Distribution in a Phantom Using 8MHz RF capacitive Type hyperthermia
이종영(Jong Young Lee),박경란(Kyung Ran Park),김계준(Kye Jun Kim),성기준(Ki Joon Sung) 대한방사선종양학회 1991 Radiation Oncology Journal Vol.9 No.2
8MHz 고주파 유전형 가열장치로 모형을 가열할 때에 전극의 크기와 모형의 두께에 따른 온도 분포를 알아보기 위하여 다양한 크기의 전극과 다양한 두께의 모형을 조합하여 실험하였다. 전극은 10, 15, 20, 25, 그리고 30cm 크기를 사용하였고 모형은 10, 15, 20, 25, 그리고 30cm 두께를 사용하였다. 모형의 두께가 25cm이상일 경우에는 전극의 크기가 모형의 두께보다 크거나 혹은 같을때에 중심부에 균일한 온도 분포를 얻을 수 있었으나, 무형의 두께가 20cm이하일 경우에는 전극의 크기가 모형의 두께와 같을 때는 균일한 온도 분포를 얻을 수 없었고 전극의 크기가 모형의 두께보다 클 때만 균일한 온도 분포를 얻을 수 있었다. 크기가 다른 한쌍의 전극을 사용하여 가열시에는 작은 전극 쪽으로 가열 부분이 집중되었고 그 현상은 전극크기의 차가 클 수록 심하였다. To evaluate the temperature distribution according to the size of the electorde and the thickness of the phantom using 8MHz radiofrequency capacitive heating device, various sized electrodoes and phantoms were used in combination. The radii of the electrodes are 10, 15, 20, 25, and 30cm and the thickness of cylindrical phantoms with diameter 30cm were 10, 15, 20, 25, 30, and 35cm. When the thickness of the phantom was 25cm or 30cm, homogenous heating was achieved by using the electrode which diameter was equal to or greater than the thickness of the phantom. When the thickness of the phantom was 20cm or less. homogenous heating was not achieved by using the electrode which diameter was equal to the thickness of the phantom, but achieved by the larger diameter of the electorode. When the sizes of paird electrodes were not equal, the smaller electrode side was preferentially heated.
김계준(Kye Jun Kim),박경란(Kyung Ran Park),이종영(Jong Young Lee),김희연(Hie Yeon Kim),성기준(Ki Joon Sung),추성실(Sung Sil Chu) 대한방사선종양학회 1992 Radiation Oncology Journal Vol.10 No.1
수술중 방사선치료를 환자에 적용하기에 앞서 본원이 보유하고 있는 LID를 이용한 전자선의선량분포 특성을 연구하였다. 이러한 선량 특성에 대한 자료는 적절한 Cone의 모향이나 크기, 에너지를 결정하게하며 빠르고 정확한 계산을 위하여 필요하다. 따라서, 본 저자들은 3-Dimensional Water Phantom Dosimetry System를 이용하여 Cone의 크기, Cone의 모양, 보상필터 사용 유무에 따라 Cone의 출력인자, 조직표면선량, 선축상 최대치 지점, 90%의 깊이, 대칭도와 편평도, SSD 보상인자, 선량분포 등을 측정하여 다음과 같은 결과를 얻었다. 1) Cone의 출력인자는 Cone 모양에 따라 각각 측정하였으며 Cone의 크기와 에너지가 작을수록 급격하게 감소하는 결과를 보였다. 2) 보상 필터의 하나인 Flattening Filter를 사용한 결과 표면 선량이 6MeV, 9MeV, 12MeV에 대하여 각각 85.3%, 89.2%, 93.4%였고, 이 보상 필터를 사용하므로 선량률과 beam의 투과율은 감소하지만 치료부위에 따라 beam의 모양을 변형시키며 특히, 표면선량을 90%나 그 이상으로 증가시킬수 있었다. 3) 3차에 걸친 beam의 collimation과 보상 필터를 결합하여 사용한 결과 매우 좋은 beam의 균일성과 편평도 뿐만아니라 90% 등선량곡선 넓이가 커지는 결과를 보였다. 4) 치료를 위하여 중요한 간격인 SSD 100cm에서 SSD 110cm까지의 출력인자는 측정치와 계산치가 Cone의 크기와 모양, 에너지에 따라 1~3%의 차이를 보였다. We have studied the dosimetric properties of electron beam using Lyon intraoperative device for intraoperative radiation therapy. The dosimetry data had compiled in such a way that a quick and correct decision regarding the cone shape, energy, and accurate calculations could be made. Using 3 dimensional water phantom, we have got the following data: cone output ratios. surface dose. dmax, d90 flatness, symmetry, beam profiles, isodose curve. and SSD correction factors, The cone output ratios were measured with straight and bevelled cone. respectively. As the cone size and the energy were reduced, the cone output ratios decreased rapidly. With the flattening filter. the surface dose increased by electron beam to 85.3%, 89.2%, and 93.4%. for 6 MeV. 9 MeV, and 12 MeV. respectively. It is important to increase the surface dose to 90% or more. Inspite of diminishing dose rate and beam penetration. this flattening filter increases the treatment volume significantly. With the combination of the three levels Collimation and the flattening filter. we achieved good homogeneity of the beam and better flatness and the diameter of the 90% isodose curve was increased. It is important to increase the area that is included in the 90% isodose level. The value of measured no calculated SSD correction factors did not agree over the clinically important range from 100 cm to 110 cm.
成耆俊 대한감염학회 1969 감염 Vol.1 No.1
근자에 우리 임상가들은 장티푸스를 의심하여 그 확진에 힘쓰고 그 경과를 추구하였으나 혈청학적으로 Widal 반응도 나타나지 않고 세균학적으로 균도 분리되지는 않으나 Chloramphemicol을 투여함으로서 1주내에 해열되고 회복되는 소위 F.U.O.(Fever Unknown Origin) 예들을 가끔 경험한다. 그 실예로서 전교수에 의하면 표1에서 보는바와 같이 1956년 6월부터 1959년 6월까지 사이에 서울대학병원에서 경험한 증예 홍수 87예 중 확진된 중예는 장티푸스가 96예, 파라티푸스 A가 10예, 파라티푸스 B가 4예로 도합 50예이고 불명열로 시종된 예는 37예로 총예수의 42%를 차지할만큼 많았다. 그러나 1959년 7월부터 1963년 7월까지 사이에는 Rickettsia의 분리, Complement Fixation Test, Rickettsial agglutination Test로서 과거라면 총수 139예 중 불명열이었을 34예 중에서 26예는 발진열(Murine Typhus)로 구명된 바 있다. 이때에는 6%에 해당하는 8예가 불명열로서 시종하였다. 이 기간 중 장티푸스를 임상적으로 의심하였던 중에 139예 중 약 5분의 1에 해당하는 증예는 발진열이었던 것이다. 표2는 1967년 8월부터 11월까지 5개월동안 가톨릭 의과대학 부속성모병원에서 전·정 교수 및 김선생에 의하여 외부개업의로부터 장티푸스를 의심하여 송원된 환자 23명에 대하여 이들을 처리한 성적을 표시하는 표인바 이 표에서는 총 증예 23예 중 티푸스균을 분리하거나(6예), Widal 반응치가 2회 이상 검사에서 640배 이상 상승된 것(7예)과 병리조직학적으로 간생검에 의하여 장티푸스로 진단된 예가 5예였다. 즉 23예 중 소위 불명열 10예가 있었는데 그중에서 5예는 같은 표에 제시된 티푸스간의 병리학적 소견 7개 Criterica에서 5개 이상 존재할 때를 양성으로 인정하여 장티푸스로 판정된 것이 5예가 있었다. 이렇게 하여도 23예 중 5예는 불명열로서 시종하였다. 이 5예 중에는 발진열이 몇 예 있었을 것으로 추정된다.