http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김병찬,정창기,김상수,박혜미,김지선,Kim, Byung Chan,Jung, Chang Gi,Kim, Sang Su,Park, Hae Mi,Kim, Ji Sun 대한핵의학기술학회 2015 핵의학 기술 Vol.19 No.1
Purpose Quality control used in laboratory help to sustain precision and accuracy consistently to ensure the Diagnostic and treatment for medical employee. To perform an evaluation in statistical manner, it is recommended to use different quality control material than calibrator from manufacturer, quality control material must include analyzed concentration perimeter, must use more than two different concentration materials and recommended to use materials to indicate the concentration in clinical use. However, currently used quality control material has limit of evaluation due to unconsidered concentration or improperly used to get clinical importance data. Therefore, we compared the value of quality control, DIACON Hormone Level 1, 2, 3 (Scantibodies, USA) and DIACON Tumor Level 1, 2, 3 which applied to clinical concentration range. Materials and Methods DIACON Hormone Level 1, 2, 3 (Scantibodies, USA) and DIACON Tumor Level 1, 2, 3 (Scantibodies, USA) that used materials and methods test to compare the result from five RIA testing institution and one institution that used Elecsys (ROCHE) and Architect (ABOTT) for each level. The reagent RIA kit that used in this experiment is followed by Table 2 and 3. Test has performed by instruction itself and follow by instruction. Results Among DIACON hormone result of twenty four items, level 1 have three items, level 2 have four items and level 3 have five items were out of manufacturer set up range based on the average value. Among DIACON tumor result of thirteen items, level 1 have three items, level 2 have four items and level 3 have five items were out of manufacturer set up range. Other result were inside of manufacturer range. Conclusion For quality control material, it is widely available in market, but it is limited for normal range which is only concerned in improper clinical value and difficult to evaluate important concentration area in terms of clinical analyze. In this experiment, we evaluate Hormone twenty three items and Tumor thirteen items with DIACON Hormone and Tumor (Scantibodies, USA) to resolve this limit and we could observe that it ca be substituted and used.
터널 갱구사면 쏘일네일링 보강배치계획을 위한 최적화기법 연구
김병찬,문현구,Kim, Byung-Chan,Moon, Hyun-Koo 한국터널지하공간학회 2016 한국터널지하공간학회논문집 Vol.18 No.6
국내 터널 갱구사면에 안정성을 확보하기 위한 사면보강은 앵커, 쏘일네일 및 록볼트 등을 이용한 다양한 공법이 사용되고 있다. 갱구 사면보강공법 및 보강재 배치, 보강재 길이 등을 선정하기 위해서는 시행착오법 등 시간이 많이 소요되기도 하며, 최적조건의 상태가 선정되었는지에 대한 검증이 쉽지 않은 경우도 발생한다. 본 연구에서는 FLAC3D 프로그램에 내장된 FISH 언어를 사용해서, 차분진화 알고리즘(DEA)을 적용한 최적화기법을 개발하였다. 갱구사면 보강공법 중에 쏘일네일링 공법에 대한 데이터베이스를 구축한 후, FLAC3D 해석을 통한 안전율 기반의 최적보강배치 계획을 선정할 수 있도록 하였다. 수치해석 결과, 완전조합(FC)에 비해서 DEA 기반의 최적화기법이 해석회수가 8배 정도 감소함을 확인하였다. 갱구 사면보강 설계 시 개발된 시스템을 활용하면, 최적보강배치 계획을 상대적으로 쉽게 선정할 수 있을 것으로 기대된다. In order to ensure the stability of tunnel portal slope, reinforcement method such as anchors, soil nails and rock bolts have been used in Korea. When selecting slope reinforcement methods in tunnel portal area such as reinforcement arrangement and length, trial and error method can be very time-consuming and it was also not easy to verify the selection of an optimum condition. In this study, using the FISH language embedded in the finite difference code FLAC3D program, the optimization technique was developed with the Differential Evolution Algorithm (DEA). After building a database on the soil nailing method in tunnel portal area, this system can be selected to an optimum arrangement plan based on the factor of safety through the FLAC3D analysis. Through the results of numerical analysis, it was confirmed that the number of analysis was decreased by about 8 times when DEA based optimization technique was used compared to the full combination (FC). In case of the design of slope reinforcement in tunnel portal area, if this built-system is used, it is expected that the selection of an optimum arrangement plan can be relatively easier.
Byung-Chan Kim(김병찬),Seok-Jae Ha(하석재),Ji-Kyung Yang(양지경),In-Cheol Lee(이인철),Dong-Seong Kang(강동성),Bong-Seok Han(한봉석),Yu-Jin Han(한유진) 한국산학기술학회 2017 한국산학기술학회논문지 Vol.18 No.4
본 와이어 본딩은 발광 다이오드의 패키징 공정에서 매우 중요한 공정으로 금 와이어를 이용하여 발광 다이오드칩과 리드 프레임을 연결함으로써 다음 공정에서의 전기적 작동을 가능하게 한다. 와이어 본딩 공정은 얇은 금속선을 연결하는 공정으로 열 압착 본딩(thermo compression bonding)과 초음파 본딩(ultra sonic bonding)이 있다. 일반적인 와이어 본딩공정은 LED 칩 상부 전극 부위에 볼 모양의 본딩을 진행하는 1st ball bonding 공정, loop를 형성하여 다른 전원 연결부위로 wire를 늘어뜨리는 looping 공정, 다른 전극 부위 상부에 stitch를 형성하여 bonding 하는 2nd stitch bonding으로 구분된다. 본 논문에서는 발광 다이오드 다이 본딩 공정에 영향을 주는 다양한 공정 변수에 대하여 분석을 수행하였다. 그리고 반응표면 분석법을 통하여 Zener 다이오드 칩과 PLCC 발광 다이오드 패키지 프레임을 연결하는 공정 최적화 결과를 도출하였다. 실험 계획법은 5인자, 3수준에 대하여 설정하였으며 4가지 반응에 대하여 인자를 분석하였다. 결과적으로 본 연구에서는 모든 목표에 맞는 최적 조건을 도출하였다. In light emitting diode (LED) chip packaging, wire bonding is an important process that connects the LED chip on the lead frame pad with the Au wire and enables electrical operation for the next process. The wire bonding process is divided by two types: thermo compression bonding and ultrasonic bonding. Generally, the wire bonding process consists of three steps: 1st ball bonding that bonds the shape of the ball on the LED chip electrode, looping process that hangs the wire toward another connecting part with a loop shape, and 2nd stitch bonding that forms and bonds to another electrode. This study analyzed the factors affecting the LED die bonding processes to optimize the process capability that bonds a small Zener diode chip on the PLCC (plastic-leaded chip-carrier) LED package frame, and then applied response surface analysis. The design of experiment (DOE) was established considering the five factors, three levels, and four responses by analyzing the factors. As a result, the optimal conditions that meet all the response targets can be derived.
김병찬 ( Kim Byung-chan ),정시현 ( Jeong Si-hyeon ),최윤수 ( Choi Yun-soo ),김동환 ( Kim Dong-hwan ),김길희 ( Kim Kil-hee ) 한국구조물진단유지관리공학회 2023 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.27 No.1
이 연구는 PC 보-기둥 접합부의 동등성 평가를 위해 RC와 PC 실험체를 계획한 뒤 실험을 진행하였다. AIJ 2002 PC골조 동등성 지침을 통해 RC 골조에 대한 PC 골조의 동등성 평가를 진행한 결과 AIJ 2002에서 제시한 동등성 지침을 모두 만족하는 것으로 나타나 PC 골조가 충분한 구조 성능을 발휘하는 것을 확인하였다.