http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이경원,박찬흔,박용래,현기훈,윤지섭,Kyung-Won Lee,Chan-Heun Park,Yong-Lai Park,Ki-Hun Hyun,Ji-Sup Yoon 대한갑상선-내분비외과학회 2013 The Koreran journal of Endocrine Surgery Vol.13 No.4
Purpose: Gasless transaxillary approach to endoscopic thyroidectomy is a widely performed procedure for benign or malignant thyroid neoplasms. However, it requires wide dissection for approaching the target area. The intravenous patient-controlled analgesia (IV PCA) is an effective method for postoperative pain control and patients can use it according to their requirement. However, patients suffer from nausea, vomiting, sleep disturbance, etc. due to opioids. Pain pump ON-Q<sup>Ⓡ</sup> PainBuster<sup>Ⓡ</sup> (pain buster) has been used widely in various surgeries for control of postoperative localizing and wide area pain without side effects of opioid analgesia because it consists of Ropivacaine. Methods: From Aug. 2008 to Jan. 2013, Gasless transaxillary endoscopic thyroidectomy was performed in 90 patients in a single institution, who were divided into three groups, including the IV PCA, pain buster, and null groups. We compared postoperative outcomes, pain severity between groups. We recorded scores immediately, 6, 12, 24, and 48 hours after surgery following visual analog pain score (VAS), and investigated hospital stay and occurrence of events of nausea, vomiting, and complications. Results: In the IV PCA group, it was discontinued due to nausea in 36.7% of patients. No significant difference in pain severity following VAS score was observed among the three groups. However, smaller numbers of analgesia injections were required in the Pain buster group than in the other groups, and fewer patients suffered from constipation, compared with the PCA group. Conclusion: Pain buster showed even effects compared to IV PCA, with few side effects and less discomfort of patients, compared with the other groups. Therefore, pain buster was thought to be the proper method for pain control after dissection of the anterior chest wall, cervical area in order to secure an operative view for transaxillary endoscopic thyroi-dectomy.
설계 모델을 이용한 $UO_2$ 펠릿 20 kg HM/batch용 분말화 장치 제작
김영환,윤지섭,정재후,홍동희,엄재법,Kim Young-Hwan,Yoon Ji-Sup,Jung Jae-Hoo,Hong Dong-Hee,Uhm Jae-Beop 한국방사성폐기물학회 2006 방사성폐기물학회지 Vol.4 No.3
Vol-oxidizer is a device to convert $UO_2$ pellets into $U_3O_8$ powder and to feed a homogeneous powder into a Metal Conversion Reactor in the ACP(Advanced Spent Fuel Conditioning Process). In this paper, we propose a design model of the vol-oxidizer, develop the new vol-oxidizer with a capacity of 20 kg HM/batch in $UO_2$ pellets, and conduct a verification for the device. Design considerations include the internal structure, the capacity, the heating position of the device, and the size. The dimensions of the new vol-oxidizer are decided by the design model. We determine a permeability test of the $U_3O_8$ measuring the temperature distribution, and the volume of $UO_2$ and $U_3O_8$. We manufactured the new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets, and then analyzed the characteristics of the $U_3O_8$ powder for the verification. The experimental results show that the permeability of the $U_3O_8$ throughout mesh enhance more than old vol-oxidizer, the oxidation time takes only 8 hours when compared with the 13 hours of the old device, and the average distribution of particle size is $40{\mu}m$. The capacities of new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets were agree well with the predictions of design model.
UO$_{2}$ 펠릿 산화로의 분말 비산 방지를 위한 최종속도 측정
김영환,윤지섭,정재후,진재현,홍동희,Kim Young-Hwan,Yoon Ji-Sup,Jung Jae-Hoo,Jin Jae-Hyun,Hong Dong-Hee 한국방사성폐기물학회 2005 방사성폐기물학회지 Vol.3 No.2
A voloxidizer for a hot cell demonstration, that handles spent fuels of a high radiation level in a limited space should be small and spent fuel powders should not be dispersed out of the equipment involved. In this study a density rate equation as well as the Stokes'equation has been proposed in order to obtain the theoretical terminal velocity of powders. The terminal velocity of U$_{3}$O$_{8}$ has been predicted by using the terminal velocity of SiO$_{2}$, and then determination has been the optimum air flow rate which is able to prevent powders from scattering. An equation which has shown a relationship between theoretical terminal velocities of U$_{3}$O$_{8}$ and SiO$_{2}$ has been derived with the help of the Stokes'equation, and then an experimental verification made for the theoretical Stokes' equation of SiO$_{2}$ by means of an experimental device made of acryl. The theoretical terminal velocity based on the proposed density rate equation has been verified by detecting U$_{3}$O$_{8}$ powders in a filter installed in the mock-up voloxidizer. As the results, the optimum air flow rates seem to be 20 LPM by the Stokes'equation while they are 14.5 L/min by the density rate equation. At the experiments with the mock-up voloxidizer, a trace amount of U$_{3}$O$_{8}$ seems to be detectable at the air flow rate of 14.5 L/min by the density rate equation, but U$_{3}$O$_{8}$ powders of 7$\mu$m diameter seem detectable at the air flow rate of 20 L/min by the Stokes'equation. It is revealed that 14.5 L/min is the optimum air flowe rate which is capable of preventing U$_{3}$O$_{8}$ powders from scattering in the UO$_{2}$ voloxidizer and the proposed density rate equation is proper to calculate the terminal velocity of U$_{3}$O$_{8}$ powders.
액와접근법을 이용한 무기하 내시경적 갑상선 절제술: 634예에 대한 수술 결과
강상욱,정종주,윤지섭<SUP>1<,SUP>,성태연,이승철,이용상,남기현,장항석,정웅윤,박정수,Sang-Wook Kang,Jong Ju Jeong,Ji-Sup Yoon,<SUP>1<,SUP>,Tae Yon Sung,Seung Chul Lee,Yong Sang Lee,Kee-Hyun Nam,Hang Seok Chang,Woong Youn Chung,and Ch 대한갑상선-내분비외과학회 2008 The Koreran journal of Endocrine Surgery Vol.8 No.1