http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
金熙鍾,柳又秀,金佳鉉,申東守,韓健模,全裕燦 東亞大學校 大學院 1984 大學院論文集 Vol.9 No.-
This paper is a study on relation between run-off ratio and antecedent discharge, run-off ratio and antecedent discharge per unit area, antecedent discharge and antecedent precipitation, by the data from the five major river basins in Korea and the small river basins in Pusan. The Nak-Dong rivers(An-Dong upper stream) f=0.4780+0.0124 ln qA r=0.99 qA=0.3368e0.1101R r=0.99 f=0.5793+0.0146 ln(qA/A) r=0.99 The Nak-Dong rivers except Ga-song station f=0.2017-0.0840 ln qA r=0.75 f=0.7012+0.0750 ln(aA/A) r=0.71 The Han rivers f=-0.0035+01267 on qA r=0.75 f=1.1311+0.1263 ln(qA/A) r=0.71 L=302.9064-43.8490 ln qA r=0.84 The Geun rivers(Mu-sin Cheon) f=0.295+0.1823 ln qA r=0.93 f=0.8417+0.1823 ln(qA/A) r=0.93 L=40.0456+62.0346 ln qA r=0.94 The Yeong-san rivers f=0.3766+0.0598 ln qA r=0.79 f=0.8084+0.0599 ln(qA/A) r=0.79 The Seom-jin rivers f=-1.3875+0.6505 ln qA r=0.92 f=2.1633+0.3465 ln(qA/A) r=0.76 Small river basin in Pusan f=0.3635+0.1120 ln qA r=0.87
유근종,한진우,김수태 창원대학교 산업기술연구소 2001 産技硏論文集 Vol.15 No.-
LES is applied to analyze transient turbulent flows which may cause thermal stripping. The LES is formulated based on Sub-Grid k model. For evaluating performance of the LES, two test cases of vertical water jet flow and parallel sodium jet flow are selected. Through the analysis, the LES confirms that it has proper ability to predict time dependent flow variables such as magnitude of temperature fluctuation and its frequency. For the better prediction, however, the LES is required to be improved through further evaluation of various SGS models and implementation of temperature SGS model into its energy equation.
상사성을 고려한 배수재 설치 연약점토 지반의 원심모델링
유남재,홍영길,정길수,조한기 강원대학교 산업기술연구소 2007 産業技術硏究 Vol.27 No.A
This paper is results of experimental research on the effect of application of similarity related to permeability of soil on the consolidation behavior as centrifuge modeling of consolidation is performed with the centrifuge model facility. In this research, the permeability of soil was controlled by changing the viscosity of porewater as the mixed water with glycerin was used during the centrifuge model experiments. The effect of drainage path on consolidation was investigated by installing the vertical drains. A serise of centrifuge model tests with conditions of single vertical and radial horizontal drainage were carried out. Kaolinite and Jumunjin standard sand were used as soft clay and surcharges respectively during tests. For testing condition of single vertical drainage considering similarity of permeability, it was found that consolidation with mixed porewater with glycerin was delayed in comparisons with test results with water only. For conditions of horizontal drainage with vertical drains, a low permeability by changing the viscosity of pore water resulted in delayed degree of consolidation at an initial stage of consolidation. But, it predicted not much differences in settlement as long as the consolidation time was sufficiently long enough to finish consolidation. Consequently, it was found that similarity in permeability should be considered to be critical for the case of centrifuge model experiments related to consolidation with long drainage path.
유남재,박병수,전상현,조한기 강원대학교 산업기술연구소 2006 産業技術硏究 Vol.26 No.B
A sensitivity analysis about effects of influencing factors on the stability of Soil cut slope was performed. Slope stability analyses were carried out under dry, rainy and seismic conditions. Dominant factors controlling the slope stability were chosen such as cohesion and internal friction angle, unit weight of soil, water table and seismic horizontal coefficient used for the slope stability during eurthquake. Parametric stability analysis with those factors was performed for sensitivity analysis. As results of analyzing the sensitivity of factors under dry and rainy conditions, effects of cohesion, internal friction angle and unit weight of soil on the stability of slope are more critical in the dry condition than in the rainy condition. Cohesion and internal friction angle are more dominant factors influencing the slope stability irrespective of dry or rainy conditions than unit weight of soil and the horizontal seismic coefficient. The unit weight and the horizontal seismic coefficient affects crucially the stability according to conditions of slope formation and dry or rainy seasons. For the effect of horizontal seismic coefficient on stability of slope, safety factor of slope is not affected significantly by dry or rainy conditions, However, increase of the horizontal seismic coefficient under the rainy condition does reduce the safety factor significantly rather than the dry condition. Therefore, it is needed that the location of the water table is assigned appropriately to satisfy the required safety factor of stability in the case of checking slope stability for the rainy and seismic conditions.
유경미,서우영,서한석,김완수,박재복,황인경 한국조리과학회 2004 한국식품조리과학회지 Vol.20 No.4
The purposes of this study were to investigate the physicochemical characteristics and storage stabilities of various sauces with added Yuza(Citrus Junos). Yuza consisted of three parts: peeled (46.17%), fleshed (43.74%) and seeded (10.09%). Yuza juice revealed 11.33% extraction yield, pH 2.85, 4.18% total acidity, 11° Brix, 1.16% transmittance and 2.63° Brix/acid ratio. Five kinds of sauces with added Yuza juice were Yuza red pepper paste sauce, Yuza soybean sauce for meat, Shahu shabu Yuza sauce, Korean Yuza vegetable sauce and Japanese Yuza soybean sauce. These sauces showed slight changes in pH, total acidity, total bacterial counts and overall sensory characteristics during storage period (60 days). In conclusion, Yuza juice could be applied to various sauces, which remained usable for 60 days.
야뇨증 환아들의 심리사회적 특성에 대한 다기관 연구 : 행동 및 정서 문제를 중심으로
조수철,김재원,신민섭,황준원,한상원,박관현,이상돈,김경도,김건석,서홍진,이유식,정재용,김영균,문두건,남궁미경,한창희,조원열,김영식,배기수,이종국,정우영,신의진 大韓神經精神醫學會 2005 신경정신의학 Vol.44 No.6
Objectives : The aim of this study was to examine the behavioral and emotional problems associated with nocturnal enuresis in Korean children. Methods : Three hundred eighteen children with nocturnal enuresis, together with their parents, completed the Child Behavior Checklist (CBCL), Disruptive Behavior Disorder Scale according to DSM-IV (DBDS), Children's Depression Inventory (CDI), State-Trait Anxiety Inventory for Children (STAIC), and Piers-Harris Children's Self-Concept Scale (PHCSC). Ninety-three normal students were selected as the control group. Results : Compared to the normal control group, the mean scores with regard to the withdrawn, social problems, attention problems, delinquent behavior, aggressive behavior, externalizing problems and total problems profiles were significantly higher in the nocturnal enuresis group according to the CBCL results. The nocturnal enuresis group also scored significantly higher in the ADHD and ODD profiles of the DBDS. The nocturnal enuresis group was more depressed and anxious than the control group according to the results of the CDI and STAI. The mean score of the PHCSC was significantly lower in the nocturnal enuresis group when compared to the normal control group. Conclusion : The results of this study suggest that children with nocturnal enuresis in Korea have clinically relevant behavioral and emotional problems. The findings support the link between nocturnal enuresis and psychopathology in Korean children.
프레탈^(R)정(실로스타졸 50mg)에 대한 실로졸^(R)정의 생물학적 동등성
최한곤,권기철,이승호,김학미,박병주,유봉규,이종달,이경희,하정희,우종수,박인숙,최진석,용철순 한국병원약사회 2003 병원약사회지 Vol.20 No.1
Bioequivalence of two cilostazol tablets, the Pletaal^(R)(Korea Otsuka Pharmaceutical Co., Ltd.) and the Cilozol^(R)(Hanmi Pharmaceutical Co., Ltd.), was evaluated according to the guideline of KFDA, Sixteen normal male volunteers(age 20~29 years old) were divided into two groups and a randomized 22 cross-over study was employed. After two tablets containing 50㎎ of cilostazol were orally administered. blood was taken at predetermined time intervals and the concentration of cilostazol in plasma was determined with an HPLC method using UV detector. The pharmacokinetic parameters(C_(max), T_(max) and AUC_(t)) were calculated and ANOVA was utilized for the statistical analysis of parameters. The results showed that the differences in C_(max), T_(max) and AUC_(t) between two tablets were 4.99%, 1.74% and 7.68%, respectively. The powers(1-β) for C_(max), T_(max) and AUC_(t) were83.92%, 80.12% and 85.03%, respectively. Detectable differences(Δ) and confidence intervals were all less than 20%, and confidence interval of all the parameters were also less than 20% at the significance level(α) of 0.05. All of these parameters met the criteria of KFDA for bioequivalence, indicating that Cilozol^(R) tablet is bioequivalent to Pletaal^(R) tablet.