http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
커튼월 단열 앵커링 유닛의 난방에너지 성능 및 경제성 평가
강승희,구보경,주선경,송승영 대한건축학회 2003 대한건축학회논문집 Vol.19 No.12
Curtain wall system has been widely applied to the residential unit of high-rise complex building which is the new trend in a recent construction market. It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. Thus this study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.
박보경,김강련 고신대학교 보건과학연구소 2006 보건과학연구소보 Vol.16 No.-
This study was carried out to improve the curricula of the two-year college courses related to beauty-care. The survey was focused to investigate the satisfaction in their majors, educational process, and course management of beauty-care students. Various questions were asked the student groups attending at the colleges in Busan. The satisfaction to their curricula was more related to the overall satisfaction rate in the course than that with the management of the curricula. The statistical analysis and interpretation of this survey was described in detail. Consequently, the beauty-care related colleges may need to develop the diversified educational system, including the customized education for the aptitude of each student, rather than to put more efforts into the hardware part, such as the investment of facilities.
김만구,강미희,임양석,박기준,황훈,이보경,홍승희,이동수 江原大學校 附設 環境硏究所 1999 環境硏究 Vol.16 No.-
The rain water samples were collected at Chunchon and Seoul by using wet only automatic sampler from January 1996 through December 1997. The daily base rain water samples collected over than 95% rainy events during the whole period. The samples were measured both pH and conductivity, and were analysed major ionic components, SO₄^(2-), NO₃^(-), Cl^(-), NH₄^(+), Ca^(2+), Na^(+) and K ^(+), by ion chromatography. In 1996, about 77% sampled rain water showed below pH 5.6 and the 60% of rain water was lower than pH 5.0. The volume weighted average pH was 4.7 at all sites. In 1997, the volume weighted average pH was 4.6 and 4.9 at Seoul and Chunchon, respectively. Among the rain water samples, 87% and 55% of samples showed below than pH 5.6 and 5.0, respectively. The pH value of Chunchon was significantly (p<0.05) lower than Seoul at the rain samples for less than 20 ㎜ rainfall. However conductivity of the rain samples were 20.9 μS/㎝ for 1996 and 27.7 μS/㎝ for 1997 at Seoul, and 19.1 μS/㎝ for 1996 and 14.1 μS/㎝ for 1997 at Chunchon. H₂SO₄AND HNO₃CONTRIBUTED 65.9% and 29.6% of free acidity at Seoul, respectively. The ratio of [NO₃^(-)]/[nss-SO₄^(2-)] were 0.43 at Seoul and 0.51 at Chunchon for rain samples for less than 20 ㎜ rainfall. The annual wet deposition of Cl^(-), NO₃^(-), SO₄^(2-), H^(+), Na^(+), NH₄^(+), K ^(+), Mg^(2+) and Ca^(2+), respectively, 568.8 ㎏/㎢, 1489.3 ㎏/㎢, 3184.8 ㎏/㎢, 20.9 ㎏/㎢, 249.4 ㎏/㎢, 1091.2 ㎏/㎢, 189.8 ㎏/㎢, 90.2 ㎏/㎢, and 702.4 ㎏/㎢ at Seoul for 1996; 656.4 ㎏/㎢, 2029.7 ㎏/㎢, 3280.7 ㎏/㎢,27.2 ㎏/㎢, 229.4 ㎏/㎢, 1063.9 ㎏/㎢, 106.9 ㎏/㎢, 7802 ㎏/㎢, and 645.3 ㎏/㎢, at Seoul for 1997; 116.9 ㎏/㎢, 983.3 ㎏/㎢, 1797.0 ㎏/㎢, 21.4 ㎏/㎢, 83.2 ㎏/㎢, 648.1 ㎏/㎢, 78.0 ㎏/㎢, 22.2 ㎏/㎢ and 368.8 ㎏/㎢ at Chunchon for 1996; 100.2 ㎏/㎢, 1077.6 ㎏/㎢, 1754.0 ㎏/㎢, 13.4 ㎏/㎢, 146.0 ㎏/㎢, 602.3 ㎏/㎢, 88.8 ㎏/㎢, 16.2 ㎏/㎢ and 206.8 ㎏/㎢ at Chunchon for 1997.
김덕구,강경보,오성보 제주대학교 산업기술연구소 2000 尖端技術硏究所論文集 Vol.11 No.1
In this paper, we describes the speed control of induction motor by vector control using DSP TMS320F240 that has the remarkable characteristics of motor control. We use a space voltage vector PWM inverter and a PI controller that is stable of transient response characteristics in a speed controller and a current controller of d-axis and q-axis. We try computer simulation about the speed control including clock wise and counter clock wise in induction motor using direct drive system attached the arm on shaft when it works by periodic variation load. So that, we verify the validity of speed control by the experiment.