http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
B 형 만성활동성간염 치료제로서 합성 α - Interferon 의 효용성
이호심(Ho Sim Lee),임종찬(Jong Chan Lim),이일남(Il Nam Lee),조현덕(Hyun Duk Cho),유병철(Byung Chul Ryoo),박실무(Sill Moo Park) 대한내과학회 1990 대한내과학회지 Vol.39 No.3
N/A Fifty eight patiens with chronic active hepatitis were entered into a therapeutic trial of 12-week period of recombinant α-interferon therapy. All patients were positive for both HBsAg and HBeAg. During the 13 to 62-week period of follow-up, 24 of 58 (47%) treated patints became negative for serum HBeAg but in 9 of these HBeAg reappeared in their serum. Fifteen patients (30%) were also positive for serum Anti-HBe but 5 of this lost Anti-HBe from serum. 9 patents positive for initial HBV DNA lost their DNA from serum. Responders had a marked improvement in serm aminotransferase activities. Seroconversion rate of female (5/9, 56%) was seemed to be higher than that of male (19/43, 45%). Comparison of responders to non-responders indicated that a high initial level of serum aminotransferuse and a severe form of hepatic histology correlate best with response to interferon herapy. 45 of 58 (78%) patients showed various adverse reactions, such as myalgia (59%), fatigue (57%), fever (52%), nausea and anorexia. Transient decrease in peripheral leukocyte and platelet count were also noted. These findings suggest that α 12-week course of recombinant α-interferon therapy would be effective and safe in approximately half of patients with chronic active hepatitis B.
이호일(Ho Il Lee),성원모(Won Mo Sung),박상훈(Sang Hun Park),윤호규(Ho Gyu Yoon) 한국산업융합학회 2006 한국산업응용학회 학술대회 논문집 Vol.- No.-
유전체인 BaTiO₃ 및 SrTiO₃와 가공성이 우수한 고분자 재료와의 복합재료를 제조하여, 유전체의 함량, 입자 크기, 계면 결합제 그리고 수지 종류에 따른 유전특성을 비교하였다. 유전체 함량이 증가하고 입자크기가 작을수록 유전성질은 증가하였고, 계면 결합제의 영향으로 배향 분극이 쉽게 일어나면 유전성질이 증가함을 확인하였다. 기저수지의 구조가 대칭이면서 분자량이 작으면 유전 성질이 감소함을 알 수 있었다. 그러므로 열가소성수지인 polyphenyleneoxide와 열경화성수지인 triallyl isocyanurate를 혼합한 복합재는 Interpenetrating network 구조를 형성하여 손실을 감소시킬 수 있었다.
C-arm Lateral view에서 피폭 저감화를 위한 방호기구 사용에 따른 유용성 평가
이호일(Ho-il Lee),정지상(Ji-sang Jung):정점용(Jum-young Jung),안치복(Chi-bock Ahn):김성식(Sung-sik Kim),박순규(Soon-kyu Park),임재식(Jea-sik Lim) 대한영상의학기술학회 2017 대한영상의학기술학회 논문지 Vol.2017 No.1
목 적 : 본 연구는 C-arm의 Lateral View에서 검사 중 Tube로부터 누설되는 선량의 거리에 따른 선량률을 조사하고, 자체 제작된 차폐 기구의 유용성에 대해 검토하고자 하였다. 대상 및 방법 : 실험에 사용된 장비는 GE사의 OEC 9800 Plus Mobile C-arm과, OSL MicroStar InLight Reader, 0.25mmPb APRON으로 자체 제작된 납 차폐기구를 사용하였다. Tube의 구분된 위치(Fig. 4)마다의 선량을 측정하였고, Tube의 측면에서 대조군(납차폐기구 비사용)과 실험군(납 차폐기구 사용)으로 나누어 0 cm부터 100 cm까지 20 cm단위로 거리에 따라 선량측정을 5회 시행하였다. 대조군과 실험군은 ‘SPSS’ program을 통해 Wilcoxon 부호-서열 검정(Wilcoxon signed-rank test)을 시행하여 유의성을 검증하였다. <실험1> Tube의 Focus를 중심으로 5방향(북, 동, 남, 서, Back)으로 나누어 Tube 표면에 OSL NanoDot를 부착하여 선량을 측정하였다. 검사조건은 C-arm의 Lateral View 위치로 되었을 때 AEC(Auto exposure control) mode에 의한 최대조건을 고려하여 Manual mode로 장비 최대 조건인 120 kVp, 8.1 mA로 고정하여 60초간 X-ray를 노출시켰다. <실험2> Tube focus를 기준으로 0 cm에서 100 cm까지 20 cm단위로 OSL NanoDot를 설치하였다. 검사 조건은 120 kVp, 8.1 mA로 고정시켜 60초간 X-ray를 노출시켰다. <실험3> 자체 제작한 납 차폐기구를 C-arm Tube에 적용하고 <실험2>와 동일한 방법으로 거리에 따른 선량률을 측정하였다. 결 과 : Tube의 측면에서 누설된 선량률의 평균값은 각각 ‘동’ 0.765 mGy/min, ‘서’ 0.759 mGy/min로 높은 값으로 측정 되었다. 반면 나머지 ‘북’ 0.011 mGy/min, ‘남’ 0.019 mGy/min, ‘Back’ 0.039 mGy/min로 낮은 값으로 측정되었다. 그 결과 수술 중 의사와 접촉하는 ‘ 동’과 ‘서’부분의 차폐가 필요한 것으로 나타났다. 자체 제작한 납 차폐기구를 적용한 결과 0 cm에서 실험군은 대조군에 67.27%의 차폐 효과가 있는 것으로 나타났다. 실험군과 대조군의 p값은 0.027(p<0.05)로 유의하였다. 결 론 : C-arm Lateral view의 피폭 저감화를 위한 자체 제작한 차폐기구를 통하여 수술실에서 C-arm lateral view를 장시간 사용하는 술자의 피폭을 줄여줄 방법으로 고려할 필요성이 있다고 사료된다. Purpose : In this study, we investigated the dose rate according to the distance of the radiation leaked from the tube during the inspection in the C-arm Lateral View and examined the usefulness of newly designed protector. Materials and Methods : The equipment used was newly designed protector with GE s OEC 9800 Plus Mobile C-arm, OSL MicroStarInLightReader and 0.25 mmPb APRON. Dose of each tube was measured at each divided position(Fig. 4). Tube was divided into a control group (non-ues protector) and an experimental group (protector was used) The dose was measured 5times from 0cm to 100 cm depending on the distance in 20 cm unit. The control and experimental groups were tested for significance by Wilcoxon signed-rank test using SPSS program. <Experiment 1> The dose was measured by attaching OSL NanoDot to tube surface in five direction (North, East, South, West, Back) centered on the focus of tube. Assuming Lateral View of C-arm, it was changed to Manual mode in consideration of maximum condition by AEC(Auto Exposure Control) mode, and X-ray was exposed for 60 seconds by fixing it at 120 kVp and 8.1 mA. <Experiment 2> OSL Nano- Dot was installed in 20 cm increments from 0 cm to 100 cm based on tube focus. The test conditions were fixed at 120 kVp and 8.1 mA, and the X-ray was exposed for 60 seconds. <Experiment 3> The newly designed protector was applied to C-arm tube and dose rate along distance was measured in same manner as <Experiment 2> Result : The mean value of dose rate leaked from side of tube was measured as ‘East’0.765 mGy/min and ‘West’0.759 mGy/min. On the other hand, the values were measured as ‘North’0.011 mGy/min, ‘South’0.019 mGy/min and ‘Back.’0.039 mGy/min. As a result, it is necessary to shield the East’ and West that contact the doctor during surgery. As a result of using the newly designed protector, the experimental group showed a shielding effect of 67.27% in the control group at 0cm. When p value was less than 0.05 the difference between the experimental group and the control group was demonstrated significance. Conclusion : If it is necessary to examine the C-arm lateral view in a way that reduces exposure of doctor who uses C-arm lateral view for a long time in the operating room through newly designed protector for the reduction of exposure of C-arm lateral view I think.
유전자 알고리즘과 신경망을 이용한 DNA Chip 유전자 선택 방법 연구
이호일(Ho Il Lee),최요한(Yo Han Choi),윤경오(Kyong Oh Yoon),김명선(Myoung Sun Kim),강연수(Youn Soo Kang),박현석(Hyun Seok Park) 한국정보과학회 2005 한국정보과학회 학술발표논문집 Vol.32 No.2
최근 유전자 칩의 발전으로 다양하고 방대한 양의 유전자 정보를 이용한 정확하고 신뢰성 높은 분류, 군집 및 질병을 예측하는 분석 기법이 증가하고 있다. 하지만 특징적인 유전자를 선택하는 Gene Selection 기법의 종류는 많지가 않으며 주로 통계적인 방법에 의존하여 유전자를 선택하는 기법을 많이 사용하고 있다. 본 논문에서는 유전자 알고리즘과 신경망의 결합을 통한 데이터마이닝을 기반으로 신뢰성 높은 특징적인 유전자를 선택하는 Gene Selection 기법에 대하여 연구을 진행하였다.
주거지원 프로그램이 주거비부담에 미치는 영향에 관한 연구 : 저소득 청년과 노인 임차가구를 중심으로
이호일(Ho-il Lee),김지희(Ji-Hee Kim),노승한(Seung-Han Noh) 건국대학교 부동산도시연구원 2021 부동산 도시연구 Vol.14 No.1
본 연구의 목적은 저소득 청년가구와 저소득 노인가구의 주거비부담에 대한 영향을 주거지원 프로그램별로 구분하여 각 집단의 인문학적, 사회 경제적 특성을 분석하는 것이다. 본 연구에서는 주거지원 프로그램에 의해 지원받는 저소득 청년가구와 저소득 노인가구의 주거 복지 향상을 위한 정책적 시사점을 도출하기 위해 2019 주거실태조사 마이크로데이터를 활용하였다. 연구결과는 다음과 같다. 첫째, 수요 관련 주거지원 프로그램 이용 변수는 저소득 청년가구에게 양(+)의 영향을 미치고, 저소득 노인가구에게 음(-)의 영향을 미치는 것으로 나타났다. 이는 저소득 청년가구가 지원금을 대부분 주거환경의 질의 향상을 위해 임대료 지출에 사용한 반면, 저소득 노인가구는 기존의 주거환경을 유지하는 가운데 수요 관련 주거프로그램 지원금을 통해 주거비부담을 줄이기 때문으로 판단된다. 둘째, 공급 관련 주거지원 프로그램은 저소득 청년 및 노인가구 모두에 음(-)의 영향을 미치는 것으로 나타났으며, 정부에서 지원하는 공급 주거지원 프로그램이 저소득 청년 및 노인가구의 주거비부담을 감소시키는데 직접적인 영향을 미치는 것으로 나타났다. This study examines the social and economic characteristics of each young and elderly household group. We employ the 2019 Residential Survey to derive policy implications for improving housing welfare for low-income young and low-income elderly households supported by housing support programs. The results of the study are as follows. First, the use of demand-related housing support programs has a positive effect on low-income young households and a negative effect on low-income elderly households. We argue that it implies low-income young households mostly use the subsidies to spend rent to improve the quality of their residential environment while low-income elderly households spend to reduce the burden of housing cost while maintaining the existing residential environment. Second, supply-related housing support programs have negative effects on both low-income young and elderly households, and housing support programs directly affect the burden of housing costs.