http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Overexpression of the AtSTK Gene Increases Salt, PEG and ABA Tolerance in Arabidopsis
Lei Bing,Cui-Cui Feng,Jing-Lan Li,Xiao-Xu Li,Baocun Zhao,Yin-Zhu Shen,Zhan-Jing Huang,Rong-Chao Ge 한국식물학회 2013 Journal of Plant Biology Vol.56 No.6
AtSTK (At5g02800), which is a serine-threonineprotein kinase gene of Arabidopsis thaliana, was cloned, andits function was studied. The study found that the overexpressionof AtSTK could significantly improve the ability of A. thaliana to tolerate salt, PEG, and ABA stresses. RT-PCRanalysis revealed that the expression of the AtSTK genecould be obviously induced by salt, PEG, and ABA. Theexamination of the physiological characteristics showed thatthe overexpression of AtSTK in Arabidopsis significantlyreduced the plasma membrane permeability, significantlyincreased the proline content, and decreased the MDA content. These changes may reflect the physiological mechanismsthrough which AtSTK overexpression improves stress resistancein Arabidopsis. In addition, the overexpression of the AtSTKgene significantly antagonised the inhibitory effect of highconcentrations of exogenous ABA on Arabidopsis seedgermination. The subcellular localisation results showed thatAtSTK is located in both the cytosol and the nucleus. Theexamination of its tissue-specific expression showed thatAtSTK is expressed in various Arabidopsis tissues and isparticularly strongly expressed in the vessels. The signallingpathway analysis indicated that AtSTK might transfer thesalt stress signal in Arabidopsis through the MAPK pathway.
Lei Yang,Shuai Guo,Qiuling Yang,Yuankun Zhu,Bing Dai,Hailing Yu,Pei Lei,Jiecai Han,Ying Hou,Jiaqi Zhu 대한금속·재료학회 2015 ELECTRONIC MATERIALS LETTERS Vol.11 No.6
The preferentially oriented In2O3 thin films were prepared on glass substrates by conventional magnetron sputtering with Ar+ plasma exposure at room temperature. Based on the x-ray diffraction, x-ray photoelectron spectroscopy, and UV photoelectron spectroscopy results, it was found that the Ar+ plasma exposure not only enhanced the low-temperature crystallization of In2O3 thin films, but also led to a dramatic improvement in the work function. Furthermore, it demonstrated that the shift mechanism of the work function in In2O3 thin films mainly combined with theelimination of oxygen defects and the change of the preferential orientation of In2O3 film surface.
Diagnostic Accuracy of 18F-FDG-PET in Patients with Testicular Cancer: a Meta-analysis
Zhao, Jing-Yi,Ma, Xue-Lei,Li, Yan-Yan,Zhang, Bing-Lan,Li, Min-Min,Ma, Xue-Lei,Liu, Lei Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.8
Objective: Fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is a new technique for identifying different malignant tumors using different uptake values between tumor cells and normal tissues. Here we assessed the diagnostic accuracy of 18F-FDG-PET in patients with testicular cancer by pooling data of existing trials in a meta-analysis. Methods: PubMed/MEDLINE, Embase and Cochrane Central Trials databases were searched and studies published in English relating to the diagnostic value of FDG-PET for testicular cancer were collected. The summary receiver operating characteristic (SROC) curve was used to examine the FDG-PET accuracy. Results: A total of 16 studies which included 957 examinations in 807 patients (median age, 31.1 years) were analyzed. A meta-analysis was performed to combine the sensitivity and specificity and their 95% confidence intervals (CIs), from diagnostic odds ratio (DOR), positive likelihood ratios (PLR), negative likelihood ratio (NLR). SROC were derived to demonstrate the diagnostic accuracy of FDG-PET for testicular cancer. The pooled sensitivity and specificity were 0.75 (95% confidence interval (CI), 0.70-0.80) and 0.87 (95% CI, 0.84-0.89), respectively. The pooled DOR was 35.6 (95% CI, 12.9-98.3). The area under the curve (AUC) was 0.88. The pooled PLR and pooled NLR were 7.80 (95% CI, 3.73-16.3) and 0.31 (95% CI, 0.23-0.43), respectively. Conclusion: In patients with testicular cancer, 18F-FDG-PET demonstrated a high SROC area, and could be a potentially useful tool if combined with other imaging methods such as MRI and CT. Nevertheless, the literature focusing on the use of 18F-FDG-PET in this setting still remains limited.
Bing Zhao,Lei Xin,Jingyu Liu,Qun Ding 보안공학연구지원센터 2016 International Journal of Future Generation Communi Vol.9 No.4
Frequency-hopping communication has the capability to resist narrowband interference, which is in direct proportion to the hopping rate. In frequency-hopping system, interference signals exist in partial de-hopping frequency-hopping signals, equivalent to time-varying interference signals existed in the frequency-hopping signals. Through integrating the diversity combining techniques of fast frequency-hopping communication with singular value decomposition method, this paper detects the frequency-hopping points, masks them, and then combines with undisturbed frequency-hopping signals. MATLAB simulation shows that narrowband interference is well restrained and the system BER is obviously improved.
Lei Wang,Yushu Chen,Bing Zhang,Wei Chen,Chunhua Wang,Li Song,Ziqian Xu,Jie Zheng,Fabao Gao 대한영상의학회 2018 Korean Journal of Radiology Vol.19 No.2
Objective: A failed electrocardiography (ECG)-trigger often leads to a long acquisition time (TA) and deterioration in image quality. The purpose of this study was to evaluate and optimize the technique of self-gated (SG) cardiovascular magnetic resonance (CMR) for cardiac late gadolinium enhancement (LGE) imaging of rats with myocardial infarction/reperfusion. Materials and Methods: Cardiovascular magnetic resonance images of 10 rats were obtained using SG-LGE or ECG with respiration double-gating (ECG-RESP-gating) method at 7T to compare differences in image interference and TA between the two methods. A variety of flip angles (FA: 10°−80°) and the number of repetitions (NR: 40, 80, 150, and 300) were investigated to determine optimal scan parameters of SG-LGE technique based on image quality score and contrast-to-noise ratio (CNR). Results: Self-gated late gadolinium enhancement allowed successful scan in 10 (100%) rats. However, only 4 (40%) rats were successfully scanned with the ECG-RESP-gating method. TAs with SG-LGE varied depending on NR used (TA: 41, 82, 154, and 307 seconds, corresponding to NR of 40, 80, 150, and 300, respectively). For the ECG-RESP-gating method, the average TA was 220 seconds. For SG-LGE images, CNR (42.5 ± 5.5, 43.5 ± 7.5, 54 ± 9, 59.5 ± 8.5, 56 ± 13, 54 ± 8, and 41 ± 9) and image quality score (1.85 ± 0.75, 2.20 ± 0.83, 2.85 ± 0.37, 3.85 ± 0.52, 2.8 ± 0.51, 2.45 ± 0.76, and 1.95 ± 0.60) were achieved with different FAs (10°, 15°, 20°, 25°, 30°, 35°, and 40°, respectively). Optimal FAs of 20°−30° and NR of 80 were recommended. Conclusion: Self-gated technique can improve image quality of LGE without irregular ECG or respiration gating. Therefore, SG-LGE can be used an alternative method of ECG-RESP-gating.
Chinese Society of Allergy Guidelines for Diagnosis and Treatment of Allergic Rhinitis
Lei Cheng,Jianjun Chen,Qingling Fu,Shaoheng He,Huabin Li,Zheng Liu,Guolin Tan,Zezhang Tao,Dehui Wang,Weiping Wen,Rui Xu,Yu Xu,Qintai Yang,Chonghua Zhang,Gehua Zhang,Ruxin Zhang,Yuan Zhang,Bing Zhou,Do 대한천식알레르기학회 2018 Allergy, Asthma & Immunology Research Vol.10 No.4
Allergic rhinitis (AR) is a global health problem that causes major illnesses and disabilities worldwide. Epidemiologic studies have demonstrated that the prevalence of AR has increased progressively over the last few decades in more developed countries and currently affects up to 40% of the population worldwide. Likewise, a rising trend of AR has also been observed over the last 2-3 decades in developing countries including China, with the prevalence of AR varying widely in these countries. A survey of self-reported AR over a 6-year period in the general Chinese adult population reported that the standardized prevalence of adult AR increased from 11.1% in 2005 to 17.6% in 2011. An increasing number of original articles and imporclinical trials on the epidemiology, pathophysiologic mechanisms, diagnosis, management and comorbidities of AR in Chinese subjects have been published in international peer-reviewed journals over the past 2 decades, and substantially added to our understanding of this disease as a global problem. Although guidelines for the diagnosis and treatment of AR in Chinese subjects have also been published, they have not been translated into English and therefore not generally accessible for reference to non-Chinese speaking international medical communities. Moreover, methods for the diagnosis and treatment of AR in China have not been standardized entirely and some patients are still treated according to regional preferences. Thus, the present guidelines have been developed by the Chinese Society of Allergy to be accessible to both national and international medical communities involved in the management of AR patients. These guidelines have been prepared in line with existing international guidelines to provide evidence-based recommendations for the diagnosis and management of AR in China.
Lei Wang,Wei Luo,Liangjie Weng,Yongbo Hu,Bing Li 대한전기학회 2018 Journal of Electrical Engineering & Technology Vol.13 No.5
In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators’ (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI’s function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.