http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Nam, Hyo-Jin,Jang, Seong-Soo,Kim, Young-Sik,Lee, Caroline-Sunyong,Jin, Won-Hyeog,Cho, Il-Joo,Bu, Jong-Uk The Institute of Electronics and Information Engin 2005 Journal of semiconductor technology and science Vol.5 No.1
Silicon nitride cantilevers integrated with silicon heaters and piezoelectric sensors were developed for the scanning probe microscope (SPM) based data storage application. These nitride cantilevers are expected to have better mechanical stability and uniformity of initial bending than the previously developed silicon cantilevers. Data bits of 40 nm in diameter were recorded on PMMA film and the sensitivity of the piezoelectric sensor was 0.615 fC/nm, meaning that indentations less than 20 nm in depth can be detected. For high speed operation, $128{\times}128$ cantilever array was developed.
Nam Ji Won,Lee Jong Min,Lyo In Uk,Kwon Soon Chan,Sim Hong Bo 대한말초신경학회 2021 The Nerve Vol.7 No.1
Posterior lumbar interbody fusion (PLIF) is a well-known method for treating spinal diseases in which adjacent segment disease (ASD) is a representative complication. To correct ASD, posterior fusion is extended to the upper or lower segment, and the previous instruments are removed. However, there have been a few reports of complications after instrument removal. Here, we report on a case of compression fracture that occurred without history of trauma after ASD revision and instrument removal surgery. A 68-year-old woman underwent PLIF at L3-5 and was hospitalized for treatment of ASD. She underwent oblique lumbar interbody fusion at L2-3 after removal of the previous screws. One month later, she visited the hospital with sudden lower back pain. Plain radiography revealed a compression fracture of L4. The patient’s pain was relieved after conservative treatment. Our findings show that instrument removal during revision operations should be performed carefully because it can lead to compression fracture without a history of trauma.
Calibration of TEPC for CubeSat Experiment to Measure Space Radiation
Uk-Won Nam,Won-Kee Park,Jaejin Lee,Jeonghyun Pyo,Bong-Kon Moon,Dae-Hee Lee,Sunghwan Kim,Ho Jin,Seongwhan Lee,Jungho Kim,Hisashi Kitamura,Yukio Uchihori 한국우주과학회 2015 Journal of Astronomy and Space Sciences Vol.32 No.2
A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to 1,000 keV/μm, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.
( Nam Hoon Moon ),( Won Chul Shin ),( Min Uk Do ),( Hyung Joon Cho ),( Kuen Tak Suh ) 대한고관절학회 2018 Hip and Pelvis Vol.30 No.2
The long-term use of adefovir and tenofovir-antiviral medications commonly used to treat chronic hepatitis B-can be associated with proximal renal tubular dysfunction resulting in significant hypophosphatemic osteomalacia. However, there have been few reports about pathological fractures requiring surgical stabilization in cases of antiviral drug-induced hypophosphatemic osteomalacia. We present the case of a 51-year-old man who sustained bilateral pathological hip fractures associated with antiviral drug-induced hypophosphatemic osteomalacia. To treat a lamivudine-resistant hepatitis-B viral infection, the patient received adefovir for 7 years followed by tenofovir for the subsequent 3 years. He had suffered from polyarthralgia and generalized weakness for 2 years prior to presentation at our clinic. Misdiagnosis and inadequate management of his condition accelerated weakness of the bone matrix and ultimately induced pathological fractures. The patient was managed via cementless total hip arthroplasty on the left hip and internal fixation on the right hip. This case highlights that orthopaedic surgeons should consider the possibility of hypophosphatemic osteomalacia if patients receiving antiviral drugs complain of polyarthralgia and generalized weakness.
Calibration of TEPC for CubeSat Experiment to Measure Space Radiation
Nam, Uk-Won,Park, Won-Kee,Lee, Jaejin,Pyo, Jeonghyun,Moon, Bong-Kon,Lee, Dae-Hee,Kim, Sunghwan,Jin, Ho,Lee, Seongwhan,Kim, Jungho,Kitamura, Hisashi,Uchihori, Yukio The Korean Space Science Society 2015 Journal of Astronomy and Space Sciences Vol.32 No.2
A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.
Computational Drug Discovery Approach Based on Nuclear Factor-κB Pathway Dynamics
Nam, Ky-Youb,Oh, Won-Seok,Kim, Chul,Song, Mi-Young,Joung, Jong-Young,Kim, Sun-Young,Park, Jae-Seong,Gang, Sin-Moon,Cho, Young-Uk,No, Kyoung-Tai Korean Chemical Society 2011 Bulletin of the Korean Chemical Society Vol.32 No.12
The NF-${\kappa}B$ system of transcription factors plays a crucial role in inflammatory diseases, making it an important drug target. We combined quantitative structure activity relationships for predicting the activity of new compounds and quantitative dynamic models for the NF-${\kappa}B$ network with intracellular concentration models. GFA-MLR QSAR analysis was employed to determine the optimal QSAR equation. To validate the predictability of the $IKK{\beta}$ QSAR model for an external set of inhibitors, a set of ordinary differential equations and mass action kinetics were used for modeling the NF-${\kappa}B$ dynamic system. The reaction parameters were obtained from previously reported research. In the IKKb QSAR model, good cross-validated $q^2$ (0.782) and conventional $r^2$ (0.808) values demonstrated the correlation between the descriptors and each of their activities and reliably predicted the $IKK{\beta}$ activities. Using a developed simulation model of the NF-${\kappa}B$ signaling pathway, we demonstrated differences in $I{\kappa}B$ mRNA expression between normal and different inhibitory states. When the inhibition efficiency increased, inhibitor 1 (PS-1145) led to long-term oscillations. The combined computational modeling and NF-${\kappa}B$ dynamic simulations can be used to understand the inhibition mechanisms and thereby result in the design of mechanism-based inhibitors.
Thermo-Piezoelectric Read/Write Mechanisms for Probe-Based Data Storage
Nam, Hyo-Jin,Kim, Young-Sik,Lee, Sun-Yong,Jin, Won-Hyeog,Jang, Seong-Soo,Cho, Il-Joo,Bu, Jong-Uk The Society of Information Storage Systems 2007 정보저장시스템학회논문집 Vol.3 No.1
In this paper, a thermo-piezoelectric mechanism with integrated heaters and piezoelectric sensors has been studied for low power probe-based data storage. Silicon nitride cantilever integrated with silicon heater and piezoelectric sensor has been developed to improve the uniformity of cantilevers. Data bits of 40 nm in diameter were recorded on PMMA film. The sensitivity of the piezoelectric sensor was 0.615 fC/nm after poling the PZT layer. And, the $34\times34$ probe array integrated with CMOS circuits has been successfully developed by simple one-step bonding process. The process can simplify the process step and reduce tip wear using silicon nitride tip.
Uk-won Nam,Won-kee Park,Junga Hwang,Jongdae Sohn,Bongkon Moon,Sunghwan Kim 한국우주과학회 2020 Journal of Astronomy and Space Sciences Vol.37 No.4
We develop the tissue-equivalent proportional counter (TEPC) type’s space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 μm. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.