http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
N/O/N 박막 다이아프레임을 이용한 광섬유 압력센서의 제작 및 그 압력특성
유양욱,김명규,박동수,김창원,김진섭,이정희,손병기 경북대학교 센서기술연구소 1995 센서技術學術大會論文集 Vol.6 No.1
The 0.6 μm N/O/N triple layer, Si_(3)N_(4)(150 nm)/SiO_(2)(300 nm)/Si_(3)N_(4)(150 nm), was deposited on silicon substrate and the N/O/N thin film diaphragm was formed using anisotropic etching technique. The stress of the formed diaphragm was very small with temperature variations. Combining this diaphragm and the optical fiber, intensity-type pressure sensor was fabricated and its pressure characteristics were investigated. The relation between the optical output power, inversely proportional to the deflection of the diaphragm, and the applied pressure was almost linear in 0~77 torr range.
객체 지향 프로그램 분석을 위한 그래프 표현 도구의 설계
류희열,김진숙 동의공업대학 1998 論文集 Vol.24 No.1
Many software engineering tools and techniques rely on graphic representations of software, such as control flow graphs, data flow graphs, program dependence graphs, or system dependence graphs. These methods can't represent Object-Oriented Paradigms, such as class. object, inheritance, polymorphism, dynamic binding. In this research, we developed an Object-oriented Program Dependency Graph Representation Tool (OPDGRT). It represents Object-Oriented Paradigm. It analyzes C++ source programs and generates class dependence graphs, class hierarchy graph, and procedure dependence graphs that are stored in the information repository. Each of them can be reused, It constructs an OPDG that is composed of each of them. Other features of OPDG are (1) the representation is compacted: (2) the number of vertices is decreased: (3) the memory size and graph complexity is decreased: (4) the representation is easy to extend for the incremental development of the program, It can be used for the subsystem of testing, debugging, and maintanance tools for Object-Oriented Program.
완전 포상기태 이후 발생한 지속성 융모질환의 치료경험 2례.
이진희,류은석,김윤숙,김종수,최승도,선우재근,배동한 순천향의학연구소 2005 Journal of Soonchunhyang Medical Science Vol.11 No.1
Persistent tumor develops in approximately 20% of patients with a complete mole, and chemotherapy is required to achieve remission. Following evacuation of hydatidiform mole, careful hCG monitoring is mandatory since it is the most reliable and sensitive method for the early detection of gestational trophoblastic disease. In carefully selected patients in whom the risk of developing gestational trophoblastic disease is significant or when the availability of hCG testing is suboptimal, chemoprophylaxis has been shown to decrease the risk of gestational trophoblastic tumor. We report here two cases of patient, 16-year-old and 45-year-old women who experienced unusual course after the evacuation of a complete mole and markedly elevated serum β-hCG levels. The patient developed persistent gestational trophoblastic disease and were successfully treated with EMA-CO and hysterectomy.
이진희,류제천,김송만,박춘수 忠南大學校 産業技術硏究所 1997 산업기술연구논문집 Vol.12 No.2
Greeting the local self-government age, local finance independece rate of local autonomy is on very poor state. So, the method of discharge a cleanest water with the least expense in sewage treatment is an important factor to supply clean water to Chung-Nam, Chung-Buk and Daejoen and to preserve a water quality of Daechong Lake. Therefore, in this study, we analysed not only a facilities outline of environment office and operating state for improvement of a water quality but also investment cost, maintenance cost, reduction method of working expenses for reduction of a budget. As a result of study, it is concluded to improve sewage pipe line of separate type and to install a flow control tank and to introduce a remove technique of T-N for the purpose of water quality improvement. Also, the relation of F/M ratio and outflow quality does not exist a regular proportional expression. But, water is the cleanest condition when the F/M ratio is 0.04. And, the most suitable injection rate of chemical material was 20㎎/ℓ for Al₂(SO₄)₃(8%) and 50㎎/ℓ(0.1%) for Polymer(0.1%). As a reduction method of operation cost, it is necessary to manage a technique support team and manage a foul water plant under township by environment office. As a result of comparison of an electric fee, a chemical cost, a by-produce recycle, and a facilities improvement, total expenses was reduced about 9% in 1996.