http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Do Hyejin,Lee Chunui,Hong Hyeon Don,Hong Hyejin,Lim Hyun Kyo,Kim Sujin 대한외상학회 2023 大韓外傷學會誌 Vol.36 No.2
Submental intubation is an effective alternative technique for airway management in patients with maxillofacial trauma. Compared with tracheostomy, it is less invasive, but has risks associated with potential airway compromise such as hypoxia due to tube obstruction, collapse, and kinking. To shorten procedure time and ensure a reinforced tube lumen, we used a laparoscopic trocar as a new device for submental intubation. A 54-year-old male patient sustained a zygomaticomaxillary complex fracture and was scheduled to undergo open reduction and internal fixation. We performed intraoral intubation and made a small 1-cm incision at the submandibular midline. After dissection of the tissue from the incision site, a reinforced tube was passed using a 12-mm laparoscopic trocar. The procedure took about 5 minutes, and apnea time from disconnecting the breathing circuit and passing through the internal lumen of the trocar until it was reconnected to the ventilator was 1 minute 5 seconds. Using a laparoscopic trocar for submental intubation can reduce the time required for dissection, prevent luminal occlusion complications due to soft tissues or blood clots in the endotracheal tube, and decrease soft tissue damage.
( Do Kyeong Song ),( Jee-young Oh ),( Hyejin Lee ),( Yeon-ah Sung ) 대한내과학회 2017 The Korean Journal of Internal Medicine Vol.32 No.4
Background/Aims: Although increased serum anti-Mullerian hormone (AMH) level has been suggested to be a surrogate marker of polycystic ovarian morphology (PCOM), its association with polycystic ovary syndrome (PCOS) is controversial, and its diagnostic value has not been determined. We aimed to observe the relationship between the AMH level and PCOS phenotypes and to determine the optimal cutoff value of AMH for the diagnosis of PCOS in young Korean women. Methods: We recruited 207 women with PCOS (120 with PCOM and 87 without PCOM) and 220 regular cycling women with normoandrogenemia (100 with PCOM and 120 without PCOM). Subjects underwent testing at a single outpatient visit. Serum AMH level was measured. Results: Women with PCOS had higher serum AMH levels than did regular cycling women with normoandrogenemia (p < 0.05). Women with PCOM had higher serum AMH levels than women without PCOM, regardless of PCOS status (p < 0.05). The optimal AMH cutoff value for the diagnosis of PCOS was 10.0 ng/mL (71% sensitivity, 93% specificity). Serum AMH was an independent determinant of total testosterone after adjustment for age, body mass index, and the number of menses/year (β = 0.31, p < 0.01). An association between AMH and hyperandrogenism was only observed in women with PCOS, and it was independent of the presence of PCOM. Conclusion: The serum AMH level can be useful for the diagnosis of PCOS at any age less than 40 years, and the optimal cutoff value for the diagnosis of PCOS identified in this study of young Korean women was 10.0 ng/mL.
Do, Jung-Ah,Park, Hyejin,Kwon, Ji-Eun,Oh, Jae-Ho,Cho, Yoon-Jae,Chang, Moon-Ik,Choi, Won-Jo,Lee, Hyun-Sook,Hong, Jin-Hwan The Korean Society of Food Hygiene and Safety 2014 한국식품위생안전성학회지 Vol.29 No.4
농산물 중에 있는 제초제 saflufenacil의 잔류량을 검사하기 위해 HPLC-UVD와 LC-MS를 이용한 정확하고 감도가 좋은 분석방법을 개발하였다. Saflufenacil 잔류물은 acetone 추출, dichloromethane을 이용한 액-액 분배, silica와 carbon 카트리지 정제를 거쳐 기기분석을 수행하였다. 검량선 작성을 위해 $0.1{\sim}5.0{\mu}gmL^{-1}$ 범위로 표준품을 만들어 실험한 결과 상관계수($r^2$)는 0.999로 높은 직선성을 보였다. $0.02{\sim}0.5mgkg^{-1}$ 처리수준으로 회수율을 실험한 결과는 80.5~110.2% 이었으며, 상대표준편차는 10% 미만이었다. 분석방법의 검출한계와 정량한계는 각각 0.005와 $0.02mgL^{-1}$ 이었다. 확립된 시험법으로 본청, 부산지방식품의 약품안전청과 경인지방식품의약품안전청에서 실험실간 검증을 실시한 결과 만족스런 결과를 얻었다. 이러한 결과들을 통해 확립된 시험법은 농산물 중 saflufenacil의 잔류량 분석에 적합함을 확인할 수 있었다. Saflufenacil is a low-volatile and uracil-based herbicide. This herbicide is used for pre-and post-emergence control of major broadleaf weeds. The objective of present study was to develop and validate an analytical method for saflufenacil determination in agricultural products for ensuring the food safety. The saflufenacil residues in samples were extracted with acetone, dichloromethane, and then purified with silica and graphitized carbon cartridge. The purified samples were analyzed by HPLC-UVD and confirmed with LC-MS. The linear range of saflufenacil was $0.1{\sim}5.0{\mu}gmL^{-1}$ with the correlation coefficient (r) = 0.999. Average recoveries of saflufenacil ranged from 80.5% to 110.2% at the spiked level of $0.02{\sim}0.5mgkg^{-1}$, while the relative standard deviation was 0.3~7.3%. In addition, the limit of detection and limit of quantification were 0.005 and $0.02mgL^{-1}$, respectively. Furthermore, an interlaboratory study among three labs was conducted to validate the method, and the results were satisfactory.
Do, Jung-Ah,Park, Hyejin,Kwon, Ji-Eun,Cho, Yoon-Jae,Chang, Moon-Ik,Oh, Jae-Ho,Hwang, In-Gyun The Korean Society of Food Hygiene and Safety 2014 한국식품위생안전성학회지 Vol.29 No.4
Tridemorph is a systemic morpholine fungicide for crops. The objective of this study was to develop reliable and sensitive analytical method for determination of tridemorph residues in tea samples for ensuring the food safety. Tridemorph residues in samples were extracted with acetonitrile after hydration, partitioned with saline water, and then purified using an aminopropyl ($NH_2$) SPE cartridge. The purified samples were detected and quantified using LC-ESI-MS/MS. The linear detection limits for tridemorph ranged from 0.02 to $1.0mgL^{-1}$ with a correlation coefficient of 0.9999. The method was validated using tea samples spiked with tridemorph at different concentration levels (0.02 and $0.05{\mu}gmL^{-1}$). The average recovery ranged between 75.0 and 84.7% with relative standard deviations less than 10%. The LOD and LOQ were 0.01 and $0.02mgL^{-1}$, respectively. The developed method was applied successfully to the identification of tridemorph in real tea samples obtained from different sources, and tridemorph was not detected in any of the samples. The results show that the developed analytical method is accurate and suitable for tridemorph determination in tea samples. 차 중에 있는 살균제 tridemorph의 잔류량을 검사하기 위해 LC-ESI-MS/MS를 이용한 정확하고 감도가 좋은 분석방법을 개발하였다. Tridemorph 잔류물은 샘플을 수화한 후 acetonitrile로 추출하고, NaCl을 이용한 액-액 분배, $NH_2$ 카트리지 정제를 거쳐 기기분석을 수행하였다. 직선성은 $0.02{\sim}1.0{\mu}gmL^{-1}$ 범위에서 상관계수($r^2$) 0.9999로 높은 직선성을 보였다. 0.02와 $0.05mgkg^{-1}$ 처리수준으로 회수율을 실험한 결과는 75.0~84.7% 이었으며, 상대표준편차는 10% 미만이었다. 분석방법의 검출한계와 정량한계는 각각 0.01와 $0.02mgL^{-1}$ 이었다. 이러한 결과들을 통해 확립된 분석법은 차 중 tridemorph의 잔류량 분석에 적합함을 확인할 수 있었다.
Do, Jung-Ah,Lee, Min-Hye,Park, Hyejin,Kang, Il-Hyun,Kwon, Kisung,Oh, Jae-Ho The Korean Society of Food Hygiene and Safety 2012 한국식품위생안전성학회지 Vol.27 No.4
농산물 중에 있는 Picoxystrobin 잔류량을 검사하기 위해 가스크로마토그래프-전자포획검출기와 가스크로마토그래프-질량분석기를 이용한 간단하고 감도가 좋은 분석방법을 개발하였다. Picoxystrobin 잔류물은 acetonitrile 추출, 포화식염수를 이용한 액-액 분배, florisil 카트리지 정제 과정을 거쳐 기기분석을 수행하였다. 개발된 방법으로 Picoxystrobin 잔류허용기준이 설정된 식품인 고추와 사과 외 대표 농산물 시료 현미, 대두, 버섯, 감귤을 대상으로 농약을 0.02, 0.05, 0.5 mg/kg 농도로 처리하여 회수율을 시험한 결과는 64.0~98.3%이었으며, 상대표준편차는 10% 미만이었다. 검량선 작성을 위해 0.1~5 mg/L 범위로 표준품을 만들어 실험한 결과 상관계수($r^2$)는 0.999로 높은 직선성을 보였으며, 분석방법의 검출한계와 정량한계는 각각 0.005와 0.02 mg/kg이었다. 또한 확인시험을 위하여 질량분석기를 사용하였으며, 145와 335를 특성이온으로 선정하였다. A simple and sensitive analytical method was developed using gas chromatography with electron capture detector (GC-ECD) and gas chromatography-mass spectrometry (GC-MS) for determination of Picoxystrobin in agricultural products (apple, hulled rice, mushroom, pepper, soybean, and mandarin). Picoxystrobin residues were extracted with acetonitrile, partitioned with saline water, and then they were cleaned up on a florisil solid-phase extraction (SPE) cartridge to obtain an extract suitable for analysis by GC-ECD and GC-MS. The method was validated using 6 agricultural product samples spiked with Picoxystrobin at different concentration levels (0.02, 0.05 and 0.5 mg/L). Average recoveries of Picoxystrobin (using each concentration three replicates) ranged 64.0~98.3% with relative standard deviations less than 10%, calibration solutions concentration in the range 0.1~5 mg/L, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.02 mg/L, respectively. The result showed that the developed analytical method is suitable for Picoxystrobin determination in agricultural products.