http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
대학 내의 친환경건물 입지에 따른 에너지비용 절감 분석
위대현,최정현 한국자원공학회 2013 한국자원공학회지 Vol.50 No.2
The study compares the Ewha Campus Complex (ECC), an eco-friendly building, and a conventional reference building in terms of energy usage and electricity cost, in order to understand the general effects of energy cost savings due to the presence of eco-friendly buildings in university campuses. The result indicates that the electricity usage and associated cost per area of the ECC is indeed lower than that of the reference building. However, because of the relatively low utilization rate of the ECC in class activities, the advantage over the reference building seems to be limited at present. we compute the net present values (NPVs) of the energy cost savings from the differences between the electricity costs per area. Our NPV analysis shows that the discounted payback period (DPB) turns out to be larger than 60 years. We also analyze the eco-friendliness of the ECC by calculating the difference in greenhouse gas (GHG) emissions. The ECC shows lower GHG emissions per area by 13.5% than that of the reference building, which suggests that eco-friendly buildings can play a great role in the reduction of GHG emissions. 본 연구는 대학교에서 친환경건물 건설에 따른 에너지비용 절감의 효과를 분석하기 위하여 기존의 교내건물과 친환경건물인 ECC의 에너지이용과 전기요금을 비교하고, 이를 통하여 친환경건물의 에너지효율성, 비용효과성, 친환경성 효과를 분석해 보고자 한다. 에너지효율성 분석결과에 따르면 면적당 전력량 및 전력요금은 ECC가 기존건물보다 면적당 전력소비량과 전력요금이 낮다. 하지만, 실질적으로 학생의 수업에 활용된 공간에 대한 활용면적당 전력량 및 전력요금은 ECC가 기존건물보다 운영 상태에서 친환경성과 비용효과성의 우위가 낮아 지므로 공간의 회전율을 높여 활용면적을 높이는 것이 필요하다. 비용 효과성을 살펴보고자 두 건물에서 사용된 전력량 및 전력요금의 차이를 이용하여 친환경건물에 의한 에너지 비용 절감의 순현재가치의 합을 계산해보면, 두 건물의 단위 면적당 전력요금의 차이는 할인율 5.5%일 때 60년 동안 466,000원 이상, 할인율 4.25%일 때 60년동안 279,000원 이상 발생하여 60년 이상의 Discounted Payback Period(DPB)을 가지게 된다. 마지막으로 본 연구에서 는 친환경건물의 에너지 절감에 따른 온실가스 배출량의 차이를 계산하여 ECC의 친환경성을 분석하였다. 두 건물의 단위면적당 온실가스 배출량을 분석한 결과, ECC의 단위면적당 온실가스 배출량이 기존건물에 비해 13.5% 감소하는 것으로 나타나 친환경건물의 건설이 국가 온실가스 배출량 감소에 큰 역할을 할 수 있음을 알 수 있다.
대학단위 온실가스 관리 프로그램 개발을 위한 대학 내 시설 담당자들의 인식 조사
위대현(Daehyun Wee),김윤경(Yoon Kyung Kim),최정현(Jung Hyun Choi) 한국콘텐츠학회 2014 한국콘텐츠학회논문지 Vol.14 No.12
본 연구에서는 대학의 에너지 사용 및 온실가스 배출 활동을 체계적으로 관리할 수 있는 온실가스 통합관리 프로그램 개발을 위해 대학 내 시설 담당자들을 대상으로 설문 조사를 실시하였다. 설문 결과에 따르면 실무자들은 기후변화나 온실가스·에너지 목표관리제에 대한 이해도가 높은 편이었으나, 대학의 에너지 사용량 및 그에 따른 온실가스 배출량에 관해서는 상대적으로 이해가 부족한 것으로 나타났다. 설문조사의 내용을 바탕으로 본 연구에서 도출한 온실가스 관리 시스템 개발의 기본 방향 및 고려 요소는 다음과 같다. 온실가스 관리 시스템은 현재의 온실가스 배출량을 정확히 파악하고, 대학의 온실가스 배출 특성을 정확히 파악하며, 사용자의 편의를 도모하는 수단들이 구현될 수 있도록 개발되어져야 한다. 더하여 온실가스 관리 시스템에 대한 적극적인 교육과 홍보가 이루어져야 한다. 본 연구에서 진행한 설문조사의 결과는 효과적인 온실가스 관리 프로그램의 개발 방향을 모색하기 위한 기초자료로서 높은 활용도를 갖는다. We examine the awareness of the facility managers in Korean universities and colleges over the global climate change and over the national greenhouse gas (GHG)·energy target management program via a questionnaire survey. The result shows that the survey participants maintain high awareness on global and national issues including the climate change and the concept of the national GHG management framework. On the other hand, the responsibility of universities and colleges associated to these issues is not recognized as well, showing the necessity for further education. Additionally, important implications on the direction and the major factors that should be considered during the development of a GHG management program for universities and colleges are deduced from the result of the survey. In order to be effective in universities and colleges, a GHG management program must be able to estimate the present level of emissions accurately, to address campus-specific emissions characteristics, and to facilitate ease use for generic users. At the same time, active supporting services including education and promotion should be incorporated. The survey result can be utilized as basic data in guiding the future development of effective GHG management programs.
메탄의 생물학적 산화에 미치는 아민계 악취 화합물의 영향
문경은,김태관,위대현,조경숙 한국냄새환경학회 2014 실내환경 및 냄새 학회지 Vol.13 No.4
Landfills are nettlesome sources of malodorous gases as well as methane that has the second largest radiative forcing of long residence-greenhouse gases, followed carbon dioxide. Because methane and malodorous gases are simultaneously emitted in landfills, investigation of whether or not methane and malodorous gases affect each other’s degradation is important. Amines such as monomethylamine(MMA), dimethylamine(DMA) and trimethylamine(TMA) are representative malodorous gases from landfills. In this study, the effect of amines on the bio-oxidation of methane was evaluated using a methane-oxidizing consortium where the dominant bacteria were Methylocystis spp. Amines inhibited the methane oxidation by the consortium, and the inhibition effect increased in the order of TMA > DMA > MMA. Methane oxidation rates in the consortium decreased with increasing amine/methane ratio(mol/mol). These results can be used to design and optimize the biological processes for simultaneous removal of methane and malodorous gases.